Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement Techniques

Fundamental limitations on the accuracy of simultaneous measurements of optical field parameters

Vadim I. Smirnov

Published Nov 29, 2010• 3 citations
Publisher
DOI
10.1007/s11018-010-9611-x

Related papers

Multiparameter quantum metrology with bright solitons

A. P. Alodjants, Dmitriy V. Tsarev, S. G. Osipov +2 more

We consider the problem of quantum metrology with simultaneous measurement of several phase parameters in the framework of current tendencies of development of alternative navigation. The fundamental limits of linear and nonlinear metrology are studied. The effect of losses on the accuracy of quantum metrology for several parameters is revealed. A realistic scenario for preparing three-mode NooN states using atomic bright solitons is proposed.

Известия Российской академии наук Серия физическая•Jun 15, 2024•0 citations

Simultaneously measuring position and momentum of optical fields

Gregory A. Howland, James Schneeloch, Daniel J. Lum +1 more

SPIE Newsroom•Jun 10, 2015•0 citations

Multiparameter Quantum Metrology with Bright Solitons

A. P. Alodjants, Dmitriy V. Tsarev, S. G. Osipov +2 more

Abstract A quantum metrology problem of simultaneous measurement and estimation of several phase parameters was considered in the framework of current tendencies of development of alternative navigation. The fundamental limits of both linear and nonlinear metrology were studied. The effect of losses on the accuracy of quantum metrology of several phase parameters was analyzed. A method to prepare three-mode N00N- states using atomic bright solitons was proposed.

Bulletin of the Russian Academy of Sciences Physics•Jun 1, 2024•0 citations

Fundamental light-field measurement schemes

H. Kühn, D.‐G. Welsch, Wilhelm Vogel

•May 8, 1994•0 citations

The Coherence Properties of Optical Fields

E. Wolf

•Jan 1, 1956•3 citations

Noise limits of polar-interferogram estimation at low light levels

Xin Liu, Mengmeng Zang, Ying Wang +2 more

In many applications using light for practical purposes, the accuracy of optical experiment is limited most fundamentally by the finite amount of light utilized in the measurements. Special emphasis should be put on interferometry aimed at measuring the parameters of simple fringe patterns due to the following reasons. First, fringe parameter measurement provides a relatively well defined and tractable example of application of the theory. The desired parameters are easily defined, and methods for their measurement are readily devised based on common sense. Second, fringe parameter measurement is central to all problems involving coherence. The fundamental descriptors of light waves utilized in coherence theory are in fact measurable parameters of fringes. By examining the limitations to fringe parameter measurement, we are actually examining the limitations to the measurability of coherence itself. In this paper, fundamental limitations of estimating the amplitudes and phases of polar-interferograms recorded at low light levels are investigated. By modeling the receiver as a spatial array of photon-counting detectors, results are obtained that permit specification of the minimum number of photoevents required for estimation of fringe parameters to a given accuracy. Both a discrete Fourier-transform estimator and an optimum joint maximum-likelihood estimator are considered to specify the limiting performance of all unbiased estimators in terms of the collected light flux.

SPIE Conference on Quantum and Nonlinear Optics•Oct 8, 2021•0 citations
In many applications using light for practical purposes, the accuracy of optical experiment is limited most fundamentally by the finite amount of light utilized in the measurements. Special emphasis should be put on interferometry aimed at measuring the parameters of simple fringe patterns due to the following reasons. First, fringe parameter measurement provides a relatively well defined and tractable example of application of the theory. The desired parameters are easily defined, and methods for their measurement are readily devised based on common sense. Second, fringe parameter measurement is central to all problems involving coherence. The fundamental descriptors of light waves utilized in coherence theory are in fact measurable parameters of fringes. By examining the limitations to fringe parameter measurement, we are actually examining the limitations to the measurability of coherence itself. In this paper, fundamental limitations of estimating the amplitudes and phases of polar-interferograms recorded at low light levels are investigated. By modeling the receiver as a spatial array of photon-counting detectors, results are obtained that permit specification of the minimum number of photoevents required for estimation of fringe parameters to a given accuracy. Both a discrete Fourier-transform estimator and an optimum joint maximum-likelihood estimator are considered to specify the limiting performance of all unbiased estimators in terms of the collected light flux.