Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment

The ALPHA antihydrogen trapping apparatus

C. Amole, Gorm Bruun Andresen, M. D. Ashkezari, M. Baquero-Ruiz, William Alan Bertsche, Paul David Bowe, Eoin Butler, A. Capra, Patrick Carpenter, Claudio Lenz Cesar, S. Chapman, M. Charlton, Adam Deller, S. Eriksson, J. Escallier, J. Fajans, Tim Friesen, M. Fujiwara, D. R. Gill, Andrea Gutierrez, Jeffrey Scott Hangst, W. N. Hardy, R. Hayano, M. E. Hayden, Andrew James Humphries, J. L. Hurt, Richard Hydomako, Christopher Aled Isaac, M.J. Jenkins, S. Jonsell, L. V. Jørgensen, Sean Kerrigan, L. L. Kurchaninov, N. Madsen, A. Marone, J. T. K. McKenna, S. Menary, Paul J. Nolan, K. Olchanski, Art Olin, B. Parker, Alexander P. Povilus, Petteri Pusa, F. Robicheaux, E. Sarid, D. Seddon, S. Seif El Nasr, Daniel Miranda Silveira, Chukman So, James William Storey, R. I. Thompson, Jim Thornhill, D. Wells, Dirk Peter van der Werf, Jonathan Syrkin Wurtele, Y. Yamazaki

Published Oct 1, 2013• 67 citations
Publisher

Abstract

The ALPHA collaboration, based at CERN, has recently succeeded in confining cold antihydrogen atoms in a magnetic minimum neutral atom trap and has performed the first study of a resonant transition of the anti-atoms. The ALPHA apparatus will be described herein, with emphasis on the structural aspects, diagnostic methods and techniques that have enabled antihydrogen trapping and experimentation to be achieved.

DOI
10.1016/j.nima.2013.09.043

Related papers

Antihydrogen Trapped in the ALPHA Experiment

Paul David Bowe

<!--HTML-->In 2010 the ALPHA collaboration succeeded in trapping antihydrogen atoms for the first time.[i] Stored antihydrogen promises to be a unique tool for making high precision measurements of the structure of this first anti-atom. Achieving this milestone presented several substantial experimental challenges and this talk will describe how they were overcome. The unique design features of the ALPHA apparatus will be explained.[ii] These allow a high intensity positron source and an antiproton imaging detector similar to the one used in the ATHENA[iii] experiment to be combined with an innovative magnet design of the anti-atom trap. This seeks to minimise the perturbations to trapped charged particles which may cause particle loss and heating[iv]. The diagnostic techniques used to measure the diameter, number, density, and temperatures of both plasmas will be presented as will the methods developed to actively compress and cool of both plasma species to sizes and temperatures [v],[vi], [vii] where trapping attempts with a reasonable chance of success can be tried. The results of the successful trapping experiments will be outlined as well as some subsequent experiments to improve the trapping rate and storage time. [i] 'Trapped antihydrogen' G.B. Andresen et al., Nature 468, 673 (2010) [ii]'A Magnetic Trap for Antihydrogen Confinement' W. Bertsche et al., Nucl. Instr. Meth. Phys. Res. A566, 746 (2006) [iii] Production and detection of cold antihydrogen atoms M.Amoretti et al., Nature 419, 456 (2002). [iv]' Antihydrogen formation dynamics in a multipolar neutral anti-atom trap' G.B. Andresen et al., Phys. Lett. B 685, 141 (2010) [v]' Evaporative Cooling of Antiprotons to Cryogenic Temperatures', G.B. Andresen et al. Phys. Rev. Lett 105, 013003 (2010) [vi]'Compression of Antiproton Clouds for Antihydrogen Trapping' G. B. Andresen et al. Phys. Rev. Lett 100, 203401 (2008) [vii] 'Autoresonant Excitation of Antiproton Plasmas' G.B. Andresen et al., Phys. Rev. Lett. 106, 025002 (2011) Organizer: Ferdinand Hahn PH/DT Detector Seminar webpage

•Feb 25, 2011•0 citations

The ALPHA-2 apparatus - facilitating experimentation with trapped antihydrogen

R. Akbari, B. X. R. Alves, C.J. Baker +58 more

This paper describes the ALPHA-2 apparatus, used at the CERN Antiproton Decelerator facility for the study of trapped antihydrogen atoms. Details of both the construction and performance are included. Prominence is given to both the new and the improved features, with respect to the original ALPHA assembly, of the apparatus including a stand-alone antiproton catching trap, the traps used to mix antiparticles to produce the anti-atoms, the magnetic atom trap used to hold some of them, and access for laser light to facilitate excitation of the antihydrogen 1 S -2 P and 1 S -2 S transitions.

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Jan 21, 2025•7 citations

Probing Trapped Antihydrogen. In Situ Diagnostics and Observations of Quantum Transitions

Tim Friesen

Antihydrogen, the bound state of a positron and an antiproton, is the simplest pure anti-atomic system and an excellent candidate to test the symmetry between matter and antimatter. This thesis focuses on the magnetic confinement of antihydrogen and the first ever resonant interaction with trapped antihydrogen, as performed by the ALPHA collaboration. The ALPHA apparatus and the techniques that have been developed to form, trap, probe, and detect antihydrogen atoms will be described in detail. The first successful demonstration of trapped antihydrogen will then be described. In the initial demonstrations, 38 trapped antihydrogen atoms were detected after being confined for at least 172 ms. Since then, over 400 antihydrogen atoms have been trapped and confinement times of 1000 s (over 15 minutes) have been demonstrated. Spectroscopy of these trapped antihydrogen atoms is the next major step forward. As an initial proof-of-principle demonstration, ALPHA induced and observed reso- nant positron spin flip (PSR) transitions between the ground states of antihydrogen. Because of the strong magnetic field dependence of these transition frequencies, the success of this experiment relied heavily on the ability to measure the magnetic field seen by the antihydrogen atoms. A novel method to measure the magnetic field in situ by detecting the cyclotron resonance of a trapped electron plasma is presented. This method allowed ALPHA to measure the magnetic field strength at the minimum of the magnetic antihydrogen trap to within 1.4 parts in 103. Hardware improvements and further study should allow this resolution to be improved by several orders of magnitude. The cyclotron resonance measurements can also be applied as a roughdiagnostic of a microwave field within the ALPHA apparatus. This allowed for important diagnostics of the microwave field used to excite the PSR transitions. Finally, the experimental results demonstrating resonant PSR transitions in antihydrogen are presented. This experiment is the first ever spectroscopic measurement of antihydrogen and an important step towards future precision spectroscopy.

•Jan 31, 2014•1 citation

First Attempts at Antihydrogen Trapping in ALPHA

Gorm Bruun Andresen, William Alan Bertsche, Paul David Bowe +37 more

The ALPHA apparatus is designed to produce and trap antihydrogen atoms. The device comprises a multifunction Penning trap and a superconducting, neutral atom trap having a minimum‐B configuration. The atom trap features an octupole magnet for transverse confinement and solenoidal mirror coils for longitudinal confinement. The magnetic trap employs a fast shutdown system to maximize the probability of detecting the annihilation of released antihydrogen. In this article we describe the first attempts to observe antihydrogen trapping.

AIP conference proceedings•Jan 1, 2008•4 citations

Progress toward cold antihydrogen

G. Gabrielse, J. Estrada, Steven Peil +3 more

The production and study of cold antihydrogen will require the manipulation of dense and cold, single component plasmas of antiprotons and positrons. The undertaking will build upon the experience of the nonneutral plasma physics community. Annihilations of the antimatter particles in the plasmas can be imaged, offering unique diagnostic opportunities not available to this community when electrons and protons are used. The techniques developed by our TRAP collaboration to capture and cool antiprotons will certainly be used by our expanded ATRAP collaboration, and by the competing ATHENA Collaboration, both working at the nearly completed AD facility of CERN. We recently demonstrated a new techniques for accumulating cold positrons directly into a cryogenic vacuum system. The closest we have come to low energy antihydrogen so far is to confine cold positrons and cold antiprotons within the same trap structure and vacuum container. Finally, we mention that stored electrons have been cooled to 70 mK, the first time that elementary particles have been cooled below 4 K. In such an apparatus it should be possible to study highly magnetized plasmas of electrons or positrons at this new low temperature.

AIP conference proceedings•Jan 1, 1999•1 citation

Physics with antihydrogen

William Alan Bertsche, Eoin Butler, M. Charlton +1 more

Performing measurements of the properties of antihydrogen, the bound state of an antiproton and a positron, and comparing the results with those for ordinary hydrogen, has long been seen as a route to test some of the fundamental principles of physics. There has been much experimental progress in this direction in recent years, and antihydrogen is now routinely created and trapped and a range of exciting measurements probing the foundations of modern physics are planned or underway. In this contribution we review the techniques developed to facilitate the capture and manipulation of positrons and antiprotons, along with procedures to bring them together to create antihydrogen. Once formed, the antihydrogen has been detected by its destruction via annihilation or field ionization, and aspects of the methodologies involved are summarized. Magnetic minimum neutral atom traps have been employed to allow some of the antihydrogen created to be held for considerable periods. We describe such devices, and their implementation, along with the cusp magnetic trap used to produce the first evidence for a low-energy beam of antihydrogen. The experiments performed to date on antihydrogen are discussed, including the first observation of a resonant quantum transition and the analyses that have yielded a limit on the electrical neutrality of the anti-atom and placed crude bounds on its gravitational behaviour. Our review concludes with an outlook, including the new ELENA extension to the antiproton decelerator facility at CERN, together with summaries of how we envisage the major threads of antihydrogen physics will progress in the coming years.

Journal of Physics B Atomic Molecular and Optical Physics•Oct 6, 2015•44 citations
The ALPHA collaboration, based at CERN, has recently succeeded in confining cold antihydrogen atoms in a magnetic minimum neutral atom trap and has performed the first study of a resonant transition of the anti-atoms. The ALPHA apparatus will be described herein, with emphasis on the structural aspects, diagnostic methods and techniques that have enabled antihydrogen trapping and experimentation to be achieved.
<!--HTML-->In 2010 the ALPHA collaboration succeeded in trapping antihydrogen atoms for the first time.[i] Stored antihydrogen promises to be a unique tool for making high precision measurements of the structure of this first anti-atom. Achieving this milestone presented several substantial experimental challenges and this talk will describe how they were overcome. The unique design features of the ALPHA apparatus will be explained.[ii] These allow a high intensity positron source and an antiproton imaging detector similar to the one used in the ATHENA[iii] experiment to be combined with an innovative magnet design of the anti-atom trap. This seeks to minimise the perturbations to trapped charged particles which may cause particle loss and heating[iv]. The diagnostic techniques used to measure the diameter, number, density, and temperatures of both plasmas will be presented as will the methods developed to actively compress and cool of both plasma species to sizes and temperatures [v],[vi], [vii] where trapping attempts with a reasonable chance of success can be tried. The results of the successful trapping experiments will be outlined as well as some subsequent experiments to improve the trapping rate and storage time. [i] 'Trapped antihydrogen' G.B. Andresen et al., Nature 468, 673 (2010) [ii]'A Magnetic Trap for Antihydrogen Confinement' W. Bertsche et al., Nucl. Instr. Meth. Phys. Res. A566, 746 (2006) [iii] Production and detection of cold antihydrogen atoms M.Amoretti et al., Nature 419, 456 (2002). [iv]' Antihydrogen formation dynamics in a multipolar neutral anti-atom trap' G.B. Andresen et al., Phys. Lett. B 685, 141 (2010) [v]' Evaporative Cooling of Antiprotons to Cryogenic Temperatures', G.B. Andresen et al. Phys. Rev. Lett 105, 013003 (2010) [vi]'Compression of Antiproton Clouds for Antihydrogen Trapping' G. B. Andresen et al. Phys. Rev. Lett 100, 203401 (2008) [vii] 'Autoresonant Excitation of Antiproton Plasmas' G.B. Andresen et al., Phys. Rev. Lett. 106, 025002 (2011) Organizer: Ferdinand Hahn PH/DT Detector Seminar webpage
This paper describes the ALPHA-2 apparatus, used at the CERN Antiproton Decelerator facility for the study of trapped antihydrogen atoms. Details of both the construction and performance are included. Prominence is given to both the new and the improved features, with respect to the original ALPHA assembly, of the apparatus including a stand-alone antiproton catching trap, the traps used to mix antiparticles to produce the anti-atoms, the magnetic atom trap used to hold some of them, and access for laser light to facilitate excitation of the antihydrogen 1 S -2 P and 1 S -2 S transitions.
Antihydrogen, the bound state of a positron and an antiproton, is the simplest pure anti-atomic system and an excellent candidate to test the symmetry between matter and antimatter. This thesis focuses on the magnetic confinement of antihydrogen and the first ever resonant interaction with trapped antihydrogen, as performed by the ALPHA collaboration. The ALPHA apparatus and the techniques that have been developed to form, trap, probe, and detect antihydrogen atoms will be described in detail. The first successful demonstration of trapped antihydrogen will then be described. In the initial demonstrations, 38 trapped antihydrogen atoms were detected after being confined for at least 172 ms. Since then, over 400 antihydrogen atoms have been trapped and confinement times of 1000 s (over 15 minutes) have been demonstrated. Spectroscopy of these trapped antihydrogen atoms is the next major step forward. As an initial proof-of-principle demonstration, ALPHA induced and observed reso- nant positron spin flip (PSR) transitions between the ground states of antihydrogen. Because of the strong magnetic field dependence of these transition frequencies, the success of this experiment relied heavily on the ability to measure the magnetic field seen by the antihydrogen atoms. A novel method to measure the magnetic field in situ by detecting the cyclotron resonance of a trapped electron plasma is presented. This method allowed ALPHA to measure the magnetic field strength at the minimum of the magnetic antihydrogen trap to within 1.4 parts in 103. Hardware improvements and further study should allow this resolution to be improved by several orders of magnitude. The cyclotron resonance measurements can also be applied as a roughdiagnostic of a microwave field within the ALPHA apparatus. This allowed for important diagnostics of the microwave field used to excite the PSR transitions. Finally, the experimental results demonstrating resonant PSR transitions in antihydrogen are presented. This experiment is the first ever spectroscopic measurement of antihydrogen and an important step towards future precision spectroscopy.
The ALPHA apparatus is designed to produce and trap antihydrogen atoms. The device comprises a multifunction Penning trap and a superconducting, neutral atom trap having a minimum‐B configuration. The atom trap features an octupole magnet for transverse confinement and solenoidal mirror coils for longitudinal confinement. The magnetic trap employs a fast shutdown system to maximize the probability of detecting the annihilation of released antihydrogen. In this article we describe the first attempts to observe antihydrogen trapping.
The production and study of cold antihydrogen will require the manipulation of dense and cold, single component plasmas of antiprotons and positrons. The undertaking will build upon the experience of the nonneutral plasma physics community. Annihilations of the antimatter particles in the plasmas can be imaged, offering unique diagnostic opportunities not available to this community when electrons and protons are used. The techniques developed by our TRAP collaboration to capture and cool antiprotons will certainly be used by our expanded ATRAP collaboration, and by the competing ATHENA Collaboration, both working at the nearly completed AD facility of CERN. We recently demonstrated a new techniques for accumulating cold positrons directly into a cryogenic vacuum system. The closest we have come to low energy antihydrogen so far is to confine cold positrons and cold antiprotons within the same trap structure and vacuum container. Finally, we mention that stored electrons have been cooled to 70 mK, the first time that elementary particles have been cooled below 4 K. In such an apparatus it should be possible to study highly magnetized plasmas of electrons or positrons at this new low temperature.
Performing measurements of the properties of antihydrogen, the bound state of an antiproton and a positron, and comparing the results with those for ordinary hydrogen, has long been seen as a route to test some of the fundamental principles of physics. There has been much experimental progress in this direction in recent years, and antihydrogen is now routinely created and trapped and a range of exciting measurements probing the foundations of modern physics are planned or underway. In this contribution we review the techniques developed to facilitate the capture and manipulation of positrons and antiprotons, along with procedures to bring them together to create antihydrogen. Once formed, the antihydrogen has been detected by its destruction via annihilation or field ionization, and aspects of the methodologies involved are summarized. Magnetic minimum neutral atom traps have been employed to allow some of the antihydrogen created to be held for considerable periods. We describe such devices, and their implementation, along with the cusp magnetic trap used to produce the first evidence for a low-energy beam of antihydrogen. The experiments performed to date on antihydrogen are discussed, including the first observation of a resonant quantum transition and the analyses that have yielded a limit on the electrical neutrality of the anti-atom and placed crude bounds on its gravitational behaviour. Our review concludes with an outlook, including the new ELENA extension to the antiproton decelerator facility at CERN, together with summaries of how we envisage the major threads of antihydrogen physics will progress in the coming years.