Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Last results on CHARLI, the LHA atomic clock using isotropic light

C. Guillemot, P. Petit, Constance Valentin, N. Dimarcq

Published Jan 22, 2003• 0 citations
Publisher

Abstract

CHARLI (in French Configuration d'Horloge a Atomes Refroidis en Lumiere Isotrope), is the very first LHA atomic clock using a source of Cesium atoms cooled in isotropic light. We briefly recall the configuration of CHARLI and expose our latest experimental results as well as our computed advances.
DOI
10.1109/freq.1999.840715

Related papers

Microwave interrogation of cesium atoms cooled in isotropic light

Constance Valentin, Emmanuel Guillot, C. Guillemot +2 more

Describes here a configuration of an atomic clock using a source of cesium atoms cooled with isotropic light. This three-dimensional (3-D)-cooling scheme yields a number of atoms of nearly 10/sup 9/ with a temperature below 100 /spl mu/K. These values are suitable for metrological applications. We present the preliminary results obtained and give a first estimation of the frequency performances for this kind of atomic clock.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2001•4 citations

Toward compact clocks with cold cesium atoms

C. Guillemot, Emmanuel Guillot, P. Petit +2 more

We present first a new 3-dimensional cooling configuration with isotropic light. We demonstrate that this cooling technique is very efficient and easy to operate. Secondly, we present two simple clock configurations using a source of atoms cooled in isotropic light. We expect these clocks to be very compact with good frequency performances.

Conference on Precision Electromagnetic Measurements•Nov 27, 2002•0 citations

HORACE: atomic clock with cooled atoms in a cell

Emmanuel Guillot, Paul-Éric Pottie, Constance Valentin +2 more

Our aim is to use cold atoms not for reducing instability or inaccuracy in the range of 10/sup -16/ or better, but to use them for reducing the size of atomic clocks. The key idea of HORACE is to fold in a microwave cavity every zone of the atomic resonator of a standard clock: zones of cooling and atomic preparation, zone of interrogation and zone of detection. Then the cell of HORACE has to be a microwave cavity as well as an optical cavity. Thus cooling of cesium atoms can only be obtained by isotropic cooling light generated inside it. In this paper, we first expose the main features of HORACE and two different configurations. Metrological aspects as well as the way the atoms would be efficiently cooled are then developed. A preliminary validation of HORACE is also demonstrated.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•3 citations

Study of 133 cesium atoms laser cooling in a 3D speckle field and development of a compact atomic clock

S. Trémine

Le projet HORACE consiste en la réalisation d'une horloge atomique compacte de hautes performances exploitant le refroidissement laser d'atomes de 133Cs en "lumière isotrope", en visant principalement le marché des horloges embarquées. Afin d'obtenir un dispositif de faible encombrement, nous réalisons en un lieu unique l'ensemble des phases de la séquence d'horloge (refroidissement, préparation, interrogation et détection). Ceci est rendu possible grâce à l'utilisation d'une cavité d'interrogation à la fois résonnante à la fréquence de la transition d'horloge, et faisant office de sphère intégrante pour la lumière de refroidissement. L'essentiel du travail de thèse présenté ici est consacré à l'étude expérimentale du refroidissement dans le champ de speckle 3D généré à l’intérieur de cette cavité. En limitant le refroidissement à une simple phase de capture, environ 3x108 atomes sont refroidis à des températures cinétiques inférieures à 60 K. Nous montrons par ailleurs qu'une répartition inhomogène de l'énergie optique dans la cavité conduit à scinder la phase de refroidissement sub-Doppler en deux étapes. Malgré le caractère aléatoire de la polarisation entre « grains » de speckle adjacents, la dynamique du refroidissement en régime sub-Doppler que nous observons est identique à celle suivie par des atomes refroidis au sein d’un réseau optique conventionnel. La dernière partie de ce mémoire est consacrée à l’aspect métrologique du projet où la séquence complète de l’horloge est démontrée pour la 1ère fois dans une zone d’interaction unique. Une stabilité relative de fréquence de 2x10-13-1/2 est attendue pour un fonctionnement terrestre de l’horloge.

•Jun 10, 2016•0 citations

Light-shift and temperature-shift studies in atomic clocks based on Coherent Population Trapping

D. Miletic

Les horloges atomiques à cellules exploitent une transition de l’état fondamental d’un atome alcalin afin d’obtenir une référence de fréquence stable. La cellule contenant ces atomes est au le cœur de ce type d’horloges. Une horloge atomique à cellule peut être réalisée selon deux principes différents: La Double Résonnance (DR) et le Piégeage Cohérent des Populations (CPT). Dans le cas de la DR, les atomes sont pompés optiquement dans l’état désiré, puis interrogés par un champ micro-onde résonnant avec la transition dite “horloge”. Dans le cas de la CPT, les deux états fondamentaux de l’atome alcalin sont couplés à un état excité commun en utilisant deux champs électromagnétiques cohérents (ici, la fréquence de transition micro-onde est appliquée à travers la différence de fréquence entre les deux champs électromagnétiques cohérents). Les atomes sont ainsi «piégés» dans une superposition cohérente des deux états fondamentaux, appelée «état noir». La fréquence d’une horloge atomique à cellule est sensibile aux variations de divers paramètres, tels que: les propriétés de la lumière utilisée pour l’excitation (à travers l’effet du «déplacement radiatif»), de la pression du gaz tampon dans la cellule, de la température de la cellule, etc. Il est donc très important de stabiliser tous ces paramètres et de trouver une configuration qui minimise la sensibilité de l’horloge aux variations de ces paramètres. Cette thèse décrit l’étude de deux horloges atomiques de laboratoire, basées sur la DR et la CPT, utilisant des cellules de tailles et contenus différents. L’impact de la source lumineuse y est également étudié. La partie principale de cette thèse se concentre sur l’étude du déplacement radiatif et du décalage en température (temperature-shift) des deux types d’horloges atomiques. Ces études incluent un développement théorique ainsi que des mesures expérimentales de ces phénomènes, montrant une bonne correspondance entre eux. Deux nouvelles approches de suppression de ces taux de variation de fréquence sont proposées pour les horloges CPT. Le premiére est la suppression du déplacement radiatif en fonction de la température de la cellule. La seconde est la suppression du taux de variation de fréquence en température. La suppression du taux variation de fréquence en température est obtenue à une température coïncidant avec la température de la cellule à laquelle le déplacement radiatif d’intensité est supprimé. De plus, cette température se trouve est dans une gamme favorable à l’opération de l’horloge. La stabilité en fréquence des horloges DR et CPT est mesurée avec deux types de cellules: des cellules avec gaz tampon et des cellules avec revêtement. La première mesure à long-terme de stabilité en fréquence avec une cellule à revêtement est présentée dans cette thèse. Les résultats obtenus permettront la réalisation de nouvelles horloges atomiques miniatures basées sur le principe CPT, ayant des stabilités en fréquence de l’ordre de 10-11 à 10 000s, ce qui permettra de produire une nouvelle génération d’instruments portables pour le positionnement, la navigation, la synchronization des réseaux de distribution d’energie (smart-grids) ou encore les télécommunications. De plus, les résultats discutés dans cette thèse ont ètè utilisés dans l’élaboration de la première horloge atomique miniature Européenne., Vapor-cell atomic clocks exploit the ground-state microwave transition in an alkali atom to provide a stable frequency reference. At the heart of a conventional vapor-cell atomic clock is a cell containing the alkali atoms. A vapor-cell atomic clock can be realized using two different basic principles: Double Resonance (DR) and Coherent Population Trapping (CPT). In DR, the alkali atoms are optically pumped in order to be placed in the desired states, and the microwave resonances are excited by a microwave field resonant with the clock transition. In the CPT principle, the two ground-state atomic levels of the alkali atom are coupled to a common excited state, using two coherent electromagnetic fields (here, the microwave transition frequency is present in the frequency difference of the two coherent electromagnetic fields). The atoms are trapped in a coherent superposition of the ground states, called a dark state. The frequency of the vapor-cell atomic clocks can shift due to various residual variations such as: the properties of the light field (through the light-shift effect), the buffer gas pressure in the resonance cell, the temperature of the clock cell, and others. It is therefore critical to carefully stabilize all these parameters and to find a clock operational scheme that minimizes the sensitivity of the clock frequency towards them. This thesis presents the studies on two laboratory atomic clocks: based on DR and CPT, using different vapor-cell content and size and different laser wavelengths. The main part of this thesis is focused on the study of the light-shift and temperature-shift phenomena in DR and CPT atomic clocks. These studies include theoretical developments and experimental measurements of these phenomena, showing a good agreement between them. Two novel approaches for the CPT vapor-cell atomic clock frequency shift suppression are proposed. The first is on the light-shift suppression as function of the miniature vapor-cell temperature. The second is on the temperature-shift suppression in the miniature single buffer gas vapor-cell. This temperature-shift suppression is obtained for the temperature that coincides with the cell temperature for suppressed intensity light-shift and it is also in the range of suitable temperatures for clock operation. DR and CPT clocks frequency stabilities are measured using both: buffer gas and wall-coated cell. A first ever wall-coated clock long-term frequency stability measurement is shown here. These results potentially provide possibilities for a number of applications like realization of novel CPT miniature atomic clocks with frequency stability of ~10-11 at 10 000s, which will enable a new generation of portable instruments for positioning, navigation, smart-grid synchronization and telecommunication applications. Also, the results discussed in this thesis are used in devising the first European integrated miniature atomic clock.

•Jan 1, 2013•2 citations

Numerical simulations of atomic behaviour for several configurations of cold cesium atomic clocks

Constance Valentin, N. Dimarcq, E. Fretel +3 more

We have performed numerical simulations for three atomic clocks using cold cesium atoms.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 22, 2003•3 citations
Our aim is to use cold atoms not for reducing instability or inaccuracy in the range of 10/sup -16/ or better, but to use them for reducing the size of atomic clocks. The key idea of HORACE is to fold in a microwave cavity every zone of the atomic resonator of a standard clock: zones of cooling and atomic preparation, zone of interrogation and zone of detection. Then the cell of HORACE has to be a microwave cavity as well as an optical cavity. Thus cooling of cesium atoms can only be obtained by isotropic cooling light generated inside it. In this paper, we first expose the main features of HORACE and two different configurations. Metrological aspects as well as the way the atoms would be efficiently cooled are then developed. A preliminary validation of HORACE is also demonstrated.
Le projet HORACE consiste en la réalisation d'une horloge atomique compacte de hautes performances exploitant le refroidissement laser d'atomes de 133Cs en "lumière isotrope", en visant principalement le marché des horloges embarquées. Afin d'obtenir un dispositif de faible encombrement, nous réalisons en un lieu unique l'ensemble des phases de la séquence d'horloge (refroidissement, préparation, interrogation et détection). Ceci est rendu possible grâce à l'utilisation d'une cavité d'interrogation à la fois résonnante à la fréquence de la transition d'horloge, et faisant office de sphère intégrante pour la lumière de refroidissement. L'essentiel du travail de thèse présenté ici est consacré à l'étude expérimentale du refroidissement dans le champ de speckle 3D généré à l’intérieur de cette cavité. En limitant le refroidissement à une simple phase de capture, environ 3x108 atomes sont refroidis à des températures cinétiques inférieures à 60 K. Nous montrons par ailleurs qu'une répartition inhomogène de l'énergie optique dans la cavité conduit à scinder la phase de refroidissement sub-Doppler en deux étapes. Malgré le caractère aléatoire de la polarisation entre « grains » de speckle adjacents, la dynamique du refroidissement en régime sub-Doppler que nous observons est identique à celle suivie par des atomes refroidis au sein d’un réseau optique conventionnel. La dernière partie de ce mémoire est consacrée à l’aspect métrologique du projet où la séquence complète de l’horloge est démontrée pour la 1ère fois dans une zone d’interaction unique. Une stabilité relative de fréquence de 2x10-13-1/2 est attendue pour un fonctionnement terrestre de l’horloge.
Les horloges atomiques à cellules exploitent une transition de l’état fondamental d’un atome alcalin afin d’obtenir une référence de fréquence stable. La cellule contenant ces atomes est au le cœur de ce type d’horloges. Une horloge atomique à cellule peut être réalisée selon deux principes différents: La Double Résonnance (DR) et le Piégeage Cohérent des Populations (CPT). Dans le cas de la DR, les atomes sont pompés optiquement dans l’état désiré, puis interrogés par un champ micro-onde résonnant avec la transition dite “horloge”. Dans le cas de la CPT, les deux états fondamentaux de l’atome alcalin sont couplés à un état excité commun en utilisant deux champs électromagnétiques cohérents (ici, la fréquence de transition micro-onde est appliquée à travers la différence de fréquence entre les deux champs électromagnétiques cohérents). Les atomes sont ainsi «piégés» dans une superposition cohérente des deux états fondamentaux, appelée «état noir». La fréquence d’une horloge atomique à cellule est sensibile aux variations de divers paramètres, tels que: les propriétés de la lumière utilisée pour l’excitation (à travers l’effet du «déplacement radiatif»), de la pression du gaz tampon dans la cellule, de la température de la cellule, etc. Il est donc très important de stabiliser tous ces paramètres et de trouver une configuration qui minimise la sensibilité de l’horloge aux variations de ces paramètres. Cette thèse décrit l’étude de deux horloges atomiques de laboratoire, basées sur la DR et la CPT, utilisant des cellules de tailles et contenus différents. L’impact de la source lumineuse y est également étudié. La partie principale de cette thèse se concentre sur l’étude du déplacement radiatif et du décalage en température (temperature-shift) des deux types d’horloges atomiques. Ces études incluent un développement théorique ainsi que des mesures expérimentales de ces phénomènes, montrant une bonne correspondance entre eux. Deux nouvelles approches de suppression de ces taux de variation de fréquence sont proposées pour les horloges CPT. Le premiére est la suppression du déplacement radiatif en fonction de la température de la cellule. La seconde est la suppression du taux de variation de fréquence en température. La suppression du taux variation de fréquence en température est obtenue à une température coïncidant avec la température de la cellule à laquelle le déplacement radiatif d’intensité est supprimé. De plus, cette température se trouve est dans une gamme favorable à l’opération de l’horloge. La stabilité en fréquence des horloges DR et CPT est mesurée avec deux types de cellules: des cellules avec gaz tampon et des cellules avec revêtement. La première mesure à long-terme de stabilité en fréquence avec une cellule à revêtement est présentée dans cette thèse. Les résultats obtenus permettront la réalisation de nouvelles horloges atomiques miniatures basées sur le principe CPT, ayant des stabilités en fréquence de l’ordre de 10-11 à 10 000s, ce qui permettra de produire une nouvelle génération d’instruments portables pour le positionnement, la navigation, la synchronization des réseaux de distribution d’energie (smart-grids) ou encore les télécommunications. De plus, les résultats discutés dans cette thèse ont ètè utilisés dans l’élaboration de la première horloge atomique miniature Européenne., Vapor-cell atomic clocks exploit the ground-state microwave transition in an alkali atom to provide a stable frequency reference. At the heart of a conventional vapor-cell atomic clock is a cell containing the alkali atoms. A vapor-cell atomic clock can be realized using two different basic principles: Double Resonance (DR) and Coherent Population Trapping (CPT). In DR, the alkali atoms are optically pumped in order to be placed in the desired states, and the microwave resonances are excited by a microwave field resonant with the clock transition. In the CPT principle, the two ground-state atomic levels of the alkali atom are coupled to a common excited state, using two coherent electromagnetic fields (here, the microwave transition frequency is present in the frequency difference of the two coherent electromagnetic fields). The atoms are trapped in a coherent superposition of the ground states, called a dark state. The frequency of the vapor-cell atomic clocks can shift due to various residual variations such as: the properties of the light field (through the light-shift effect), the buffer gas pressure in the resonance cell, the temperature of the clock cell, and others. It is therefore critical to carefully stabilize all these parameters and to find a clock operational scheme that minimizes the sensitivity of the clock frequency towards them. This thesis presents the studies on two laboratory atomic clocks: based on DR and CPT, using different vapor-cell content and size and different laser wavelengths. The main part of this thesis is focused on the study of the light-shift and temperature-shift phenomena in DR and CPT atomic clocks. These studies include theoretical developments and experimental measurements of these phenomena, showing a good agreement between them. Two novel approaches for the CPT vapor-cell atomic clock frequency shift suppression are proposed. The first is on the light-shift suppression as function of the miniature vapor-cell temperature. The second is on the temperature-shift suppression in the miniature single buffer gas vapor-cell. This temperature-shift suppression is obtained for the temperature that coincides with the cell temperature for suppressed intensity light-shift and it is also in the range of suitable temperatures for clock operation. DR and CPT clocks frequency stabilities are measured using both: buffer gas and wall-coated cell. A first ever wall-coated clock long-term frequency stability measurement is shown here. These results potentially provide possibilities for a number of applications like realization of novel CPT miniature atomic clocks with frequency stability of ~10-11 at 10 000s, which will enable a new generation of portable instruments for positioning, navigation, smart-grid synchronization and telecommunication applications. Also, the results discussed in this thesis are used in devising the first European integrated miniature atomic clock.