IBM Journal of Research and Development

A Note on the Resonant Modes and Spatial Coherency of a Fabry-Perot Maser Interferometer

G. J. Fan

Published Jul 1, 1964• 4 citations
Publisher

Abstract

This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.

DOI
10.1147/rd.83.0335

Related papers

Standing-wave optical bistability and instability

M. Sargent

The transmission characteristics of a Fabry-Perot cavity containing a resonant absorber are described analytically and graphically for internal fields of arbitrary intensity. The multimode instability considered by Bonifacio and Lugiato [Opt. Commun. 19 , 72 (1976)] for the unidirectional ring laser is treated for the standing-wave cavity. In particular, an instability may exist when the medium is located at one of the ends of the cavity, but not if the medium fills the cavity. The results are explained in terms of induced side-mode gain and spatial hole burning.

Soviet Journal of Quantum Electronics•Oct 31, 1980•11 citations

Atomes à I’Intérieur d’un Interféromètre Perot-Fabry

Alfred Kastler

In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.

Applied Optics•Jan 1, 1962•35 citations

Atomes à I’Intérieur d’un Interféromètre Perot-Fabry

Alfred Kastler

In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.

Applied Optics•Jan 1, 1962•123 citations

Atomes à I’Intérieur d’un Interféromètre Perot-Fabry

Alfred Kastler

In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.

Applied Optics•Jan 1, 1962•1 citation

Nonlinear dynamics in Fabry–Perot cavities

Luigi Lugiato, Franco Prati, Massimo Brambilla

In Chapters 8–13 we always assumed that the nonlinear medium is contained in a unidirectional ring cavity. The case of a Fabry–Perot cavity (Fig. 8.1) is substantially more complex because the interference of the two counterpropagating fields gives rise to a standing-wave pattern that modulates the population difference and the atomic polarization to form gratings with a spatial frequency equal to the inverse of the half-wavelength and its harmonics. Therefore the atomic variables exhibit, in addition to the slow spatial variation which characterizes the envelopes, also a fast spatial variation on the wavelength scale, and the coexistence of these two spatial scales poses a highly nontrivial problem that must be treated with care. In Chapters 9 and 11 we solved exactly the Maxwell–Bloch equations with the ring-cavity boundary conditions for both the active and the passive configuration. Exact solutions of this kind have been obtained also for the equations and boundary conditions of a Fabry–Perot cavity [117–119]. However, for the sake of simplicity we will pass directly to models that are valid in the low-transmission approximation. Again for the sake of simplicity, in this chapter we assume that n B = 1, so that the light velocity in the empty part of the cavity is the same as that in the atomic sample. By following the same line of reasoning as that which we pursued in Chapter 12, in Section 14.1 we introduce a spatial transformation of the electric-field envelopes, which leads to boundary conditions without parameters, while the parameters present in the boundary conditions of the original variables appear in the envelope equations. As in the ring-cavity case, this approach allows one to introduce the cavity modes in a natural way, and to derive a set of modal equations coupled to the equations for the atomic variables. Sets of equations of this kind are common in the laser literature, but are not derived from the true boundary conditions for the cavity.

Cambridge University Press eBooks•Feb 28, 2015•0 citations

A Fabry-Perot interferometer for atoms

Byron B. Taylor, E. Goldstein, M. Wilkens +1 more

Recent progress in atom optics has culminated in several demonstrations of atom interferometers. These rely on the passage of atoms through mechanical or light gratings and may be roughly characterized as Mach–Zehnder interferometers. In this communication, we propose a scheme to realize a Fabry–Perot interferometer for atoms. The mirrors are realized by the field gradient resulting from the spatial mode structure in optical or microwave cavities. When ultra- cold atoms impinge on such cavities, they experience quantum mechanical reflection and transmission that result in the appearance of longitudinal modes for the atomic wave function. We present a model of such a Fabry–Perot interferometer for two-level atoms. We discuss the intra-cavity matter–wave mode structure as well as the transmittivity and reflectivity characteristics of the interferometer. The potential generation of macroscopic quantum waves using such a device, as well as its potential as a sensitive photon detector, will be addressed.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations
This communication has considered the case of a Fabry-Perot cavity with light impinging on one end while the field distribution on the other end is observed. It has been shown that if one starts with a wave that can be expanded into the modes of the integral operator, and if the medium in the cavity is passive, more than one mode would be observed at the other end although the amplitude of the dominant mode can be much greater than that of the other modes. It was further shown that if there is present an active medium with sufficient gain there will be only a single mode, and the single mode is necessary and sufficient for complete spatial coherency.
The transmission characteristics of a Fabry-Perot cavity containing a resonant absorber are described analytically and graphically for internal fields of arbitrary intensity. The multimode instability considered by Bonifacio and Lugiato [Opt. Commun. 19 , 72 (1976)] for the unidirectional ring laser is treated for the standing-wave cavity. In particular, an instability may exist when the medium is located at one of the ends of the cavity, but not if the medium fills the cavity. The results are explained in terms of induced side-mode gain and spatial hole burning.
In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.
In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.
In the optical masers realized so far a Perot-Fabry device is used as a multimode cavity. It may be interesting to investigate the general properties of such a device when the emitting or the absorbing atoms are put inside the reflecting mirrors. Even in the case when this device works below the threshold of maser action it shows remarkable properties which are worthwhile studying experimentally. The following aspects are considered in the paper: In the case of external illumination, the distribution of light intensity inside a Perot-Fabry interferometer is calculated. It is shown that the local light intensity in the stationary waves inside can be much higher than the intensity of the incident light beam. The properties of light emitted by atoms inside the Perot-Fabry and emerging from it are investigated. Narrow fringes of very strong intensity can be obtained. If the emitting atoms are located in an atomic beam the central fringe has natural line width, the Doppler broadening being suppressed. The realization of a fluorescent medium of lamellar structure is discussed. This structure favors one special mode of emission fringes. Finally, the absorption of atoms inside the interferometer is studied. It is shown that this device is equivalent to a long absorption path in an ordinary light beam.
In Chapters 8–13 we always assumed that the nonlinear medium is contained in a unidirectional ring cavity. The case of a Fabry–Perot cavity (Fig. 8.1) is substantially more complex because the interference of the two counterpropagating fields gives rise to a standing-wave pattern that modulates the population difference and the atomic polarization to form gratings with a spatial frequency equal to the inverse of the half-wavelength and its harmonics. Therefore the atomic variables exhibit, in addition to the slow spatial variation which characterizes the envelopes, also a fast spatial variation on the wavelength scale, and the coexistence of these two spatial scales poses a highly nontrivial problem that must be treated with care. In Chapters 9 and 11 we solved exactly the Maxwell–Bloch equations with the ring-cavity boundary conditions for both the active and the passive configuration. Exact solutions of this kind have been obtained also for the equations and boundary conditions of a Fabry–Perot cavity [117–119]. However, for the sake of simplicity we will pass directly to models that are valid in the low-transmission approximation. Again for the sake of simplicity, in this chapter we assume that n B = 1, so that the light velocity in the empty part of the cavity is the same as that in the atomic sample. By following the same line of reasoning as that which we pursued in Chapter 12, in Section 14.1 we introduce a spatial transformation of the electric-field envelopes, which leads to boundary conditions without parameters, while the parameters present in the boundary conditions of the original variables appear in the envelope equations. As in the ring-cavity case, this approach allows one to introduce the cavity modes in a natural way, and to derive a set of modal equations coupled to the equations for the atomic variables. Sets of equations of this kind are common in the laser literature, but are not derived from the true boundary conditions for the cavity.
Recent progress in atom optics has culminated in several demonstrations of atom interferometers. These rely on the passage of atoms through mechanical or light gratings and may be roughly characterized as Mach–Zehnder interferometers. In this communication, we propose a scheme to realize a Fabry–Perot interferometer for atoms. The mirrors are realized by the field gradient resulting from the spatial mode structure in optical or microwave cavities. When ultra- cold atoms impinge on such cavities, they experience quantum mechanical reflection and transmission that result in the appearance of longitudinal modes for the atomic wave function. We present a model of such a Fabry–Perot interferometer for two-level atoms. We discuss the intra-cavity matter–wave mode structure as well as the transmittivity and reflectivity characteristics of the interferometer. The potential generation of macroscopic quantum waves using such a device, as well as its potential as a sensitive photon detector, will be addressed.