Kluwer Academic Publishers eBooks

Atom Interferometry With Ultra-Cold Atoms

Mark A. Kasevich

Published Dec 11, 2005• 0 citations
Publisher

Abstract

The current generation of single-particle force sensors have achieved performance levels where they now compete with state-of-the-art instruments. Whether Bose-condensed atomic sources will enable a further performance gain remains to be seen. However, there are a number of tantalising possibilities which are emerging from current studies of condensate cohenerence properties.

DOI
10.1007/0-306-47103-5_16

Related papers

Precision Atom Interferometry

Sheng-wei Chiow, Susannah M. Dickerson, Jason M. Hogan +4 more

While the current generation of atom interferometric force sensors perform at levels which compete favorably with the existing state-of-the-art, the full potential of these sensors has yet to be realized. Advances in the quality of the atom optics used to manipulate atomic de Broglie waves, the brightness of the atomic sources, and attaining full control over the quantum many-body wavefunction of the ensemble of interfering particles all promise to bring the performance levels of these sensors to levels of precision which may have dramatic future scientific and technological impact.

•Aug 28, 2011•0 citations

A TRANSPORTABLE COLD ATOM INERTIAL SENSOR FOR SPACE APPLICATIONS

Vincent Ménoret, Rémi Geiger, Guillaume Stern +7 more

Atom interferometry has hugely benefitted from advances made in cold atom physics over the past twenty years, and ultra-precise quantum sensors are now available for a wide range of applications [1]. In particular, cold atom interferometers have shown excellent performances in the field of acceleration and rotation

•Jan 1, 2010•0 citations

Advances in Atom Interferometry and their Impacts on the Performance of Quantum Accelerometers On-board Future Satellite Gravity Missions

Alireza HosseiniArani, Manuel Schilling, Quentin Beaufils +6 more

Recent advances in cold atom interferometry have cleared the path for space applications of quantum inertial sensors, whose level of stability is expected to increase dramatically with the longer interrogation times accessible in space. In this study, an in-orbit model is developed for a Mach-Zehnder-type cold-atom accelerometer. Performance tests are realized under different assumptions about the positioning and rotation compensation method, and the impact of various sources of errors on instrument stability is evaluated. Current and future advances for space-based atom interferometry are discussed, and their impact on the performance of quantum sensors on-board satellite gravity missions is investigated in three different scenarios: state-of-the-art scenario(expected to be ready to launch in 5 years), near-future (expected to be launched in the next 10 to 15 years)and far-future scenarios (expected for the next 20 to 25 years). Our results indicate that the highest sensitivity is achievable by positioning the electrostatic accelerometer at the center of mass of the satellite and the quantum accelerometer aside, on the cross-track axis of the satellite. We show that one can achieve a sensitivity level close to 5×10-10m/s2/Hz with the current state-of-the-art technology. We also estimate that in the near and far-future, atom interferometry in space is expected to achieve sensitivity levels of 1×10-11m/s2/Hz and 1×10-12m/s2/Hz, respectively. A roadmap for improvements in atom interferometry is provided that would maximize the performance of future quantum accelerometers, considering their technical capabilities. Finally, the possibility and challenges of having ultra-sensitive atom interferometry in space for future space missions are discussed.

arXiv:2404.10471•Advances in Space Research•Jun 26, 2024•21 citations

Magnetic trapping for an atom-chip-based gravimeter

Jonas Matthias

In the past century, the development of gravimeters with low uncertainty and long-term stability has led to new fields of research in geodesy and geoscience. Decreasing the instrumental measurement uncertainty further will enable observations of previously inaccessible phenomena, for instance, mass transport in hydrology and volcanology. During the last decades, quantum sensors based on the interference of cold atoms have been developed. Using a cold atomic gas as test mass, the accuracy of these sensors is not limited by mechanical properties but by effects caused by the thermal expansion of the atomic ensemble. The application of ultra-cold atomic ensembles with lower expansion rates in atom interferometer gravimeters is projected to reduce the leading order uncertainties by more than an order of magnitude. At the same time, atom chip technology makes it possible to prepare ultra-cold atomic ensembles at a high repetition rate and to miniaturise the sensor size. These advancements promise the realisation of an absolute gravimeter with unprecedented accuracy. This thesis describes the design considerations and the assembly of the transportable Quantum Gravimeter (QG-1) based on light-pulse atom interferometry of Bose-Einstein condensates (BEC) prepared on an atom chip. It is estimated, that the two leading order uncertainties of systematic biases governing the instrumental measurement uncertainty of current generation cold atom gravimeters are reduced to less than 1 nm/s² in the QG-1 apparatus. The established design of an atom-chip-based BEC source pioneered in the Quantus collaboration is modified to meet the requirements of QG-1. A free optical aperture of 18 mm for the interferometry laser beam is realised by changing the orientation of the atom-chip-based BEC source. Therefore, a new layout of the mesoscopic wire structure of the atom chip is required. The design described in this thesis enables atom interferometry with a free falling test mass with a baseline of 330 mm. The retro-reflection mirror is placed inside the vacuum chamber to eliminate optical elements in the atom interferometer beam path. It is mounted on a custom designed tip/tilt-stage with compact size and a large dynamic range of up to a hundredfold of the Earth's rotation rate for characterisation. Furthermore, a compact, robust and transportable fibre based laser system with modular electronics and a computer control system are set up. The key result of this thesis is the reliable operation of the ultra-cold atomic source on the atom chip. After optimisation of the trap loading procedure for a high atom number and low excitation of oscillations, it was shown that the necessary design change of the atom chip allows for efficient operation. The compressed magnetic trap has a geometrically averaged trap frequency of 2π · 256 Hz and the trapped ensemble has a lifetime of 3.2 s. The evaporative cooling procedure starts with 3.3 · 10⁷ atoms at a temperature of 166 μK. Within 1.3 s, or 2.3 s for the complete sequence, 3000 atoms are prepared at a temperature of 160 nK close to the critical temperature for Bose-Einstein condensation.

•Jan 1, 2020•0 citations

Atom interferometer inertial force sensors

Dallin Durfee, J. B. Fixler, G. T. Foster +4 more

We report on the progress in the development of high sensitivity and accuracy inertial force sensors which are based on atom interference techniques.

IEEE/ION Position Location and Navigation Symposium•Nov 7, 2002•5 citations

Towards Atom Interferometry using Bose-Einstein Condensates

Charles A. Sackett

Bulletin of the American Physical Society•Nov 11, 2005•0 citations
The current generation of single-particle force sensors have achieved performance levels where they now compete with state-of-the-art instruments. Whether Bose-condensed atomic sources will enable a further performance gain remains to be seen. However, there are a number of tantalising possibilities which are emerging from current studies of condensate cohenerence properties.
While the current generation of atom interferometric force sensors perform at levels which compete favorably with the existing state-of-the-art, the full potential of these sensors has yet to be realized. Advances in the quality of the atom optics used to manipulate atomic de Broglie waves, the brightness of the atomic sources, and attaining full control over the quantum many-body wavefunction of the ensemble of interfering particles all promise to bring the performance levels of these sensors to levels of precision which may have dramatic future scientific and technological impact.
Recent advances in cold atom interferometry have cleared the path for space applications of quantum inertial sensors, whose level of stability is expected to increase dramatically with the longer interrogation times accessible in space. In this study, an in-orbit model is developed for a Mach-Zehnder-type cold-atom accelerometer. Performance tests are realized under different assumptions about the positioning and rotation compensation method, and the impact of various sources of errors on instrument stability is evaluated. Current and future advances for space-based atom interferometry are discussed, and their impact on the performance of quantum sensors on-board satellite gravity missions is investigated in three different scenarios: state-of-the-art scenario(expected to be ready to launch in 5 years), near-future (expected to be launched in the next 10 to 15 years)and far-future scenarios (expected for the next 20 to 25 years). Our results indicate that the highest sensitivity is achievable by positioning the electrostatic accelerometer at the center of mass of the satellite and the quantum accelerometer aside, on the cross-track axis of the satellite. We show that one can achieve a sensitivity level close to 5×10-10m/s2/Hz with the current state-of-the-art technology. We also estimate that in the near and far-future, atom interferometry in space is expected to achieve sensitivity levels of 1×10-11m/s2/Hz and 1×10-12m/s2/Hz, respectively. A roadmap for improvements in atom interferometry is provided that would maximize the performance of future quantum accelerometers, considering their technical capabilities. Finally, the possibility and challenges of having ultra-sensitive atom interferometry in space for future space missions are discussed.
In the past century, the development of gravimeters with low uncertainty and long-term stability has led to new fields of research in geodesy and geoscience. Decreasing the instrumental measurement uncertainty further will enable observations of previously inaccessible phenomena, for instance, mass transport in hydrology and volcanology. During the last decades, quantum sensors based on the interference of cold atoms have been developed. Using a cold atomic gas as test mass, the accuracy of these sensors is not limited by mechanical properties but by effects caused by the thermal expansion of the atomic ensemble. The application of ultra-cold atomic ensembles with lower expansion rates in atom interferometer gravimeters is projected to reduce the leading order uncertainties by more than an order of magnitude. At the same time, atom chip technology makes it possible to prepare ultra-cold atomic ensembles at a high repetition rate and to miniaturise the sensor size. These advancements promise the realisation of an absolute gravimeter with unprecedented accuracy. This thesis describes the design considerations and the assembly of the transportable Quantum Gravimeter (QG-1) based on light-pulse atom interferometry of Bose-Einstein condensates (BEC) prepared on an atom chip. It is estimated, that the two leading order uncertainties of systematic biases governing the instrumental measurement uncertainty of current generation cold atom gravimeters are reduced to less than 1 nm/s² in the QG-1 apparatus. The established design of an atom-chip-based BEC source pioneered in the Quantus collaboration is modified to meet the requirements of QG-1. A free optical aperture of 18 mm for the interferometry laser beam is realised by changing the orientation of the atom-chip-based BEC source. Therefore, a new layout of the mesoscopic wire structure of the atom chip is required. The design described in this thesis enables atom interferometry with a free falling test mass with a baseline of 330 mm. The retro-reflection mirror is placed inside the vacuum chamber to eliminate optical elements in the atom interferometer beam path. It is mounted on a custom designed tip/tilt-stage with compact size and a large dynamic range of up to a hundredfold of the Earth's rotation rate for characterisation. Furthermore, a compact, robust and transportable fibre based laser system with modular electronics and a computer control system are set up. The key result of this thesis is the reliable operation of the ultra-cold atomic source on the atom chip. After optimisation of the trap loading procedure for a high atom number and low excitation of oscillations, it was shown that the necessary design change of the atom chip allows for efficient operation. The compressed magnetic trap has a geometrically averaged trap frequency of 2π · 256 Hz and the trapped ensemble has a lifetime of 3.2 s. The evaporative cooling procedure starts with 3.3 · 10⁷ atoms at a temperature of 166 μK. Within 1.3 s, or 2.3 s for the complete sequence, 3000 atoms are prepared at a temperature of 160 nK close to the critical temperature for Bose-Einstein condensation.