Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Mode optimization for quantum-state tomography with array detectors

Andrew M. C. Dawes, M. Beck, Konrad Banaszek

Published Mar 11, 2003• 12 citations
Publisher

Abstract

We demonstrate that it is possible to choose an optimal signal mode for state reconstruction when performing quantum-state tomography with array detectors. The mode optimization is done during the data analysis (i.e., after all the data have been collected.) We develop theoretically a procedure for finding the mode that satisfies a criterion which is quadratic in field operators; as examples we explicitly show how to maximize the average photon number, or the amount of quadrature squeezing. We experimentally demonstrate the technique by finding the mode which maximizes the average photon number for coherent-state signal beams occupying both linear and sinusoidal modes.

DOI
10.1103/physreva.67.032102

Related papers

Quantum State Tomography with Array Detectors

M. Beck

I propose a method for measuring the quantum state of an optical field that occupies a mode having a complicated spatial structure. The technique uses array detectors and a single, plane-wave local oscillator beam. The advantage of using array detectors is that the local oscillator is not mode matched to the field being measured, yet the deleterious effects of this mismatch on the effective detection efficiency are greatly reduced compared to using single detectors. Indeed, when the spatial mode of the signal field is describable by a real function, the effective mode-matching efficiency is unity.

Physical Review Letters•Jun 19, 2000•48 citations

Simultaneous quantum-state measurements using array detection

Andrew M. C. Dawes, M. Beck

We have simultaneously measured the quantum states of two different spatial modes of the same optical beam by performing quantum-state tomography with an array detector. Both modes are well described by coherent states, but the projection of the signal onto the local oscillator mode contains a mean of 0.09 photons, while a more complicated mode has a mean of 4.3 photons. This demonstrates that for this particular mode the effective detection efficiency when using array detection is over 40 times greater than when using single detectors.

Physical Review A•Mar 19, 2001•11 citations

Quantum-state tomography of complex multimode fields using array detectors

S. Sivakumar, G. S. Agarwal

We demonstrate that it is possible to use the balanced homodyning with array detectors to measure the quantum state of a correlated two-mode signal field. We show the applicability of the method to fields with complex mode functions, thus generalizing the work of Beck [Phys. Rev. Lett. 84, 5748 (2000)] in several important ways. We further establish that, under suitable conditions, array detector measurements from one of the two ouputs are sufficient to determine the quantum state of signal. We show the power of the method by reconstructing a truncated Perelomov state, which exhibits complicated structure in the joint probability density for the quadratures.

arXiv:quant-ph/0101070•Physical Review A•May 10, 2001•0 citations

Optimal experiment design for quantum state tomography: Fair, precise, and minimal tomography

J. Nunn, Brian J. Smith, Graciana Puentes +2 more

Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al. [R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of `minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.

arXiv:0911.4310•Physical Review A•Apr 22, 2010•39 citations

Recursive quantum detector tomography

Lijian Zhang, Animesh Datta, Hendrik B Coldenstrodt-Ronge +4 more

Conventional tomographic techniques are becoming increasingly infeasible for reconstructing the operators of quantum devices of growing sophistication. We describe a novel tomographic procedure using coherent states, which begins by reconstructing the diagonals of the operator and then each successive off-diagonal in a recursive manner. Each recursion is considerably more efficient than reconstructing the operator in its entirety, and each successive recursion involves fewer parameters. We apply our technique to reconstruct the positive-operator-valued measure corresponding to a recently developed coherent optical detector with phase sensitivity and number resolution. We discuss the effect of various parameters on the reconstruction accuracy. The results show the efficiency of the method and its robustness to experimental noise.

arXiv:1207.3501•New Journal of Physics•Nov 5, 2012•44 citations

Two-Stage Estimation for Quantum Detector Tomography: Error Analysis, Numerical and Experimental Results

Yuanlong Wang, Shota Yokoyama, Daoyi Dong +3 more

Quantum detector tomography is a fundamental technique for calibrating quantum devices and performing quantum engineering tasks. In this paper, a novel quantum detector tomography method is proposed. First, a series of different probe states are used to generate measurement data. Then, using constrained linear regression estimation, a stage-1 estimation of the detector is obtained. Finally, the positive semidefinite requirement is added to guarantee a physical stage-2 estimation. This Two-stage Estimation (TSE) method has computational complexity O(nd2M), where n is the number of d-dimensional detector matrices and M is the number of different probe states. An error upper bound is established, and optimization on the coherent probe states is investigated. We perform simulation and a quantum optical experiment to testify the effectiveness of the TSE method.

arXiv:1905.05323•IEEE Transactions on Information Theory•Feb 26, 2021•21 citations
We demonstrate that it is possible to choose an optimal signal mode for state reconstruction when performing quantum-state tomography with array detectors. The mode optimization is done during the data analysis (i.e., after all the data have been collected.) We develop theoretically a procedure for finding the mode that satisfies a criterion which is quadratic in field operators; as examples we explicitly show how to maximize the average photon number, or the amount of quadrature squeezing. We experimentally demonstrate the technique by finding the mode which maximizes the average photon number for coherent-state signal beams occupying both linear and sinusoidal modes.
I propose a method for measuring the quantum state of an optical field that occupies a mode having a complicated spatial structure. The technique uses array detectors and a single, plane-wave local oscillator beam. The advantage of using array detectors is that the local oscillator is not mode matched to the field being measured, yet the deleterious effects of this mismatch on the effective detection efficiency are greatly reduced compared to using single detectors. Indeed, when the spatial mode of the signal field is describable by a real function, the effective mode-matching efficiency is unity.
We have simultaneously measured the quantum states of two different spatial modes of the same optical beam by performing quantum-state tomography with an array detector. Both modes are well described by coherent states, but the projection of the signal onto the local oscillator mode contains a mean of 0.09 photons, while a more complicated mode has a mean of 4.3 photons. This demonstrates that for this particular mode the effective detection efficiency when using array detection is over 40 times greater than when using single detectors.
We demonstrate that it is possible to use the balanced homodyning with array detectors to measure the quantum state of a correlated two-mode signal field. We show the applicability of the method to fields with complex mode functions, thus generalizing the work of Beck [Phys. Rev. Lett. 84, 5748 (2000)] in several important ways. We further establish that, under suitable conditions, array detector measurements from one of the two ouputs are sufficient to determine the quantum state of signal. We show the power of the method by reconstructing a truncated Perelomov state, which exhibits complicated structure in the joint probability density for the quadratures.
Given an experimental setup and a fixed number of measurements, how should one take data to optimally reconstruct the state of a quantum system? The problem of optimal experiment design (OED) for quantum state tomography was first broached by Kosut et al. [R. Kosut, I. Walmsley, and H. Rabitz, e-print arXiv:quant-ph/0411093 (2004)]. Here we provide efficient numerical algorithms for finding the optimal design, and analytic results for the case of `minimal tomography'. We also introduce the average OED, which is independent of the state to be reconstructed, and the optimal design for tomography (ODT), which minimizes tomographic bias. Monte Carlo simulations confirm the utility of our results for qubits. Finally, we adapt our approach to deal with constrained techniques such as maximum-likelihood estimation. We find that these are less amenable to optimization than cruder reconstruction methods, such as linear inversion.
Conventional tomographic techniques are becoming increasingly infeasible for reconstructing the operators of quantum devices of growing sophistication. We describe a novel tomographic procedure using coherent states, which begins by reconstructing the diagonals of the operator and then each successive off-diagonal in a recursive manner. Each recursion is considerably more efficient than reconstructing the operator in its entirety, and each successive recursion involves fewer parameters. We apply our technique to reconstruct the positive-operator-valued measure corresponding to a recently developed coherent optical detector with phase sensitivity and number resolution. We discuss the effect of various parameters on the reconstruction accuracy. The results show the efficiency of the method and its robustness to experimental noise.
Quantum detector tomography is a fundamental technique for calibrating quantum devices and performing quantum engineering tasks. In this paper, a novel quantum detector tomography method is proposed. First, a series of different probe states are used to generate measurement data. Then, using constrained linear regression estimation, a stage-1 estimation of the detector is obtained. Finally, the positive semidefinite requirement is added to guarantee a physical stage-2 estimation. This Two-stage Estimation (TSE) method has computational complexity O(nd2M), where n is the number of d-dimensional detector matrices and M is the number of different probe states. An error upper bound is established, and optimization on the coherent probe states is investigated. We perform simulation and a quantum optical experiment to testify the effectiveness of the TSE method.