Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Effect of a magnetic field gradient and gravitational acceleration on a time-domain grating-echo interferometer

M. Weel, I. Y. Chan, Scott Beattie, Anantharaman Kumarakrishnan, David Gosset, Itay Yavin

Published Jun 28, 2006• 19 citations
Publisher

Abstract

We have observed the effects of magnetic field gradients and gravitational acceleration on grating echoes in a time-domain single state atom interferometer that uses laser cooled Rb atoms. These observations are compared to theoretical predictions based on a simplified model. The oscillatory dependence of the echo amplitude due to the magnetic field gradient is in agreement with the predicted quadratic scaling as a function of the time between excitation pulses. We also observe a linear dependence of this oscillation frequency as a function of the magnetic field gradient which is predicted by theory. In the presence of gravity, the calculations predict a quadratic dependence for the echo phase on the time between excitation pulses as well as a change in the shape of the echo envelope. We have observed both of these effects in the experiment, and we find that the change in shape is qualitatively consistent with our prediction. It is necessary to understand these effects in order to carry out high precision studies of the atomic fine-structure constant and gravitational acceleration using this interferometric technique. We also present an improved measurement of gravitational acceleration using this technique that is precise to $\ensuremath{\sim}15\phantom{\rule{0.3em}{0ex}}\mathrm{ppm}$ by exploiting the quadratic phase dependence.

DOI
10.1103/physreva.73.063624

Related papers

Atom-interferometric techniques for measuring uniform magnetic field gradients and gravitational acceleration

B. Barrett, I. Y. Chan, Anantharaman Kumarakrishnan

We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of ${}^{85}$Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of $B$ gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, $g$.

arXiv:1104.4577•Physical Review A•Dec 19, 2011•27 citations

Demonstration of improved sensitivity of echo interferometers to gravitational acceleration

Carson Mok, B. Barrett, Adam C. Carew +3 more

We have developed two configurations of an echo interferometer that rely on standing-wave excitation of a laser-cooled sample of rubidium atoms. Both configurations can be used to measure acceleration $a$ along the axis of excitation. For a two-pulse configuration, the signal from the interferometer is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. In comparison, for a three-pulse stimulated-echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency as a function of pulse spacing. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature, leading to a longer experimental time scale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms time scale. In comparison, using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a time scale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope so that the statistical error is reduced to 75 parts per billion (ppb). The inhomogeneous field of a magnetized vacuum chamber limited the experimental time scale and resulted in prominent systematic effects. Extended time scales and improved signal-to-noise ratio observed in recent echo experiments using a nonmagnetic vacuum chamber suggest that echo techniques are suitable for a high-precision measurement of gravitational acceleration $g$. We discuss methods for reducing systematic effects and improving the signal-to-noise ratio. Simulations of both AI configurations with a time scale of 300 ms suggest that an optimized experiment with improved vibration isolation and atoms selected in the ${m}_{F}=0$ state can result in measurements of $g$ statistically precise to 0.3 ppb for the two-pulse AI and 0.6 ppb for the three-pulse AI.

arXiv:1307.1902•Physical Review A•Aug 20, 2013•16 citations

Improving the sensitivity grating-echo atom interferometers for measurements of gravity

Gehrig Carlse, Jaskaran Randhawa, Alexander Pouliot +4 more

Precision measurements of gravitational acceleration g have far reaching applications in navigation and sensing as well as for tests of general relativity. Grating-echo atom interferometers (AIs) utilize simple setups and distinctive excitation schemes that involve a single excitation laser, and do not require velocity selection. They have demonstrated measurements of gravity precise to 75 parts per billion (ppb) by dropping laser-cooled atomic samples through ~ 1 cm. Here we describe progress toward realizing a cold atom gravimeter using an echo AI designed for drop heights of ~30 cm. The experimental technique involves illuminating the falling sample of laser-cooled rubidium atoms with two standing wave (sw) pulses separated by time t = T. The sw pulses are composed of two traveling-wave components, each having a wave vector of magnitude k = 2π/λ. Momentum state interference produces one-dimensional density gratings with a period λ/2 immediately after each excitation pulse. These gratings dephase due to the velocity distribution of the sample along the sw axis. The AI uses an echo technique to cancel the effect of velocity dephasing and observe a rephased density grating in the vicinity of the echo time τ = 2Τ. The grating contrast and phase are measured by coherently backscattering a traveling wave readout pulse from the sample. The grating phase, measured with respect to a vibrationally stabilized inertial reference frame, scales as 2kgΤ2. A drawback of echo AIs is the signal-to-noise ratio, which is limited by the contrast of the grating and systematic effects due the refractive index of the sample. Here, we review improvements to the experimental design and investigate methods of improving the signal-to-noise ratio by optimizing the atom-field coupling. We describe progress toward realizing our goals of increasing the grating contrast and the backscattered signal. The improved contrast is expected to allow the experiment to be carried out at a lower density to reduce corrections due to the refractive index. We discuss a variety of excitation schemes for achieving a target precision of a few ppb.

Optical and Quantum Sensing and Precision Metrology II•Mar 13, 2024•0 citations

Influence of Spontaneous Emission on a Single-State Atom Interferometer

Scott Beattie, B. Barrett, M. Weel +4 more

We have studied the effects of spontaneous emission (SE) on a single-state time domain atom interferometer (AI) that uses trapped Rb atoms. The AI uses two standing wave pulses separated by time $T$ to produce an echo signal at time $2T$ due to interference between momentum states. We find that SE influences both the shape of the echo signal and its periodic time-dependent amplitude in a manner consistent with theoretical predictions. The results show that the time-dependent signal from the AI is related to the effective radiative decay rate of the excited state. We also present results that test theoretical predictions for several properties of the echo formation such as the variation in momentum transfer due to the change in the angle between the traveling wave components of the excitation pulses, strength of the atom-field interaction, and the effect of spatial profile of the excitation beams. These studies are important for realizing precision measurements of the atomic fine structure constant and gravity using this interferometer.

Bulletin of the American Physical Society•May 29, 2008•0 citations

Influence of spontaneous emission on a single-state atom interferometer

Scott Beattie, B. Barrett, M. Weel +4 more

We have studied the effects of spontaneous emission (SE) on a single-state time domain atom interferometer (AI) that uses trapped Rb atoms. The AI uses two standing wave pulses separated by time $T$ to produce an echo signal at time $2T$ due to interference between momentum states. We find that SE influences both the shape of the echo signal and its periodic time-dependent amplitude in a manner consistent with theoretical predictions. The results show that the time-dependent signal from the AI is related to the effective radiative decay rate of the excited state. We also present results that test theoretical predictions for several properties of the echo formation such as the variation in momentum transfer due to the change in the angle between the traveling wave components of the excitation pulses, strength of the atom-field interaction, and the effect of spatial profile of the excitation beams. These studies are important for realizing precision measurements of the atomic fine structure constant and gravity using this interferometer.

Physical Review A•Jan 15, 2008•21 citations

A Transportable Gravity Gradiometer Based on Atom Interferometry

Nan Yu, Robert J. Thompson, James R. Kellogg +3 more

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

•May 1, 2010•2 citations
We have observed the effects of magnetic field gradients and gravitational acceleration on grating echoes in a time-domain single state atom interferometer that uses laser cooled Rb atoms. These observations are compared to theoretical predictions based on a simplified model. The oscillatory dependence of the echo amplitude due to the magnetic field gradient is in agreement with the predicted quadratic scaling as a function of the time between excitation pulses. We also observe a linear dependence of this oscillation frequency as a function of the magnetic field gradient which is predicted by theory. In the presence of gravity, the calculations predict a quadratic dependence for the echo phase on the time between excitation pulses as well as a change in the shape of the echo envelope. We have observed both of these effects in the experiment, and we find that the change in shape is qualitatively consistent with our prediction. It is necessary to understand these effects in order to carry out high precision studies of the atomic fine-structure constant and gravitational acceleration using this interferometric technique. We also present an improved measurement of gravitational acceleration using this technique that is precise to \ensuremath∼15ppm\ensuremath{\sim}15\phantom{\rule{0.3em}{0ex}}\mathrm{ppm}\ensuremath∼15ppm by exploiting the quadratic phase dependence.
We discuss techniques for probing the effects of a constant force acting on cold atoms using two configurations of a grating echo-type atom interferometer. Laser-cooled samples of 85{}^{85}85Rb with temperatures as low as 2.4 $\ensuremath{\mu}$K have been achieved in a new experimental apparatus with a well-controlled magnetic environment. We demonstrate interferometer signal lifetimes approaching the transit time limit in this system ($\ensuremath{\sim}270$ ms), which is comparable to the time scale achieved by Raman interferometers. Using these long time scales, we experimentally investigate the influence of a homogeneous magnetic field gradient using two- and three-pulse interferometers, which enable us to sense changes in externally applied magnetic field gradients as small as $\ensuremath{\sim}4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}5}$ G/cm. We also provide an improved theoretical description of signals generated by both interferometer configurations that accurately models experimental results. With this theory, absolute measurements of BBB gradients at the level of $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}4}$ G/cm are achieved. Finally, we contrast the suitability of the two- and three-pulse interferometers for precision measurements of the gravitational acceleration, ggg.
We have developed two configurations of an echo interferometer that rely on standing-wave excitation of a laser-cooled sample of rubidium atoms. Both configurations can be used to measure acceleration aaa along the axis of excitation. For a two-pulse configuration, the signal from the interferometer is modulated at the recoil frequency and exhibits a sinusoidal frequency chirp as a function of pulse spacing. In comparison, for a three-pulse stimulated-echo configuration, the signal is observed without recoil modulation and exhibits a modulation at a single frequency as a function of pulse spacing. The three-pulse configuration is less sensitive to effects of vibrations and magnetic field curvature, leading to a longer experimental time scale. For both configurations of the atom interferometer (AI), we show that a measurement of acceleration with a statistical precision of 0.5% can be realized by analyzing the shape of the echo envelope that has a temporal duration of a few microseconds. Using the two-pulse AI, we obtain measurements of acceleration that are statistically precise to 6 parts per million (ppm) on a 25 ms time scale. In comparison, using the three-pulse AI, we obtain measurements of acceleration that are statistically precise to 0.4 ppm on a time scale of 50 ms. A further statistical enhancement is achieved by analyzing the data across the echo envelope so that the statistical error is reduced to 75 parts per billion (ppb). The inhomogeneous field of a magnetized vacuum chamber limited the experimental time scale and resulted in prominent systematic effects. Extended time scales and improved signal-to-noise ratio observed in recent echo experiments using a nonmagnetic vacuum chamber suggest that echo techniques are suitable for a high-precision measurement of gravitational acceleration ggg. We discuss methods for reducing systematic effects and improving the signal-to-noise ratio. Simulations of both AI configurations with a time scale of 300 ms suggest that an optimized experiment with improved vibration isolation and atoms selected in the mF=0{m}_{F}=0mF​=0 state can result in measurements of ggg statistically precise to 0.3 ppb for the two-pulse AI and 0.6 ppb for the three-pulse AI.
Precision measurements of gravitational acceleration g have far reaching applications in navigation and sensing as well as for tests of general relativity. Grating-echo atom interferometers (AIs) utilize simple setups and distinctive excitation schemes that involve a single excitation laser, and do not require velocity selection. They have demonstrated measurements of gravity precise to 75 parts per billion (ppb) by dropping laser-cooled atomic samples through ~ 1 cm. Here we describe progress toward realizing a cold atom gravimeter using an echo AI designed for drop heights of ~30 cm. The experimental technique involves illuminating the falling sample of laser-cooled rubidium atoms with two standing wave (sw) pulses separated by time t = T. The sw pulses are composed of two traveling-wave components, each having a wave vector of magnitude k = 2π/λ. Momentum state interference produces one-dimensional density gratings with a period λ/2 immediately after each excitation pulse. These gratings dephase due to the velocity distribution of the sample along the sw axis. The AI uses an echo technique to cancel the effect of velocity dephasing and observe a rephased density grating in the vicinity of the echo time τ = 2Τ. The grating contrast and phase are measured by coherently backscattering a traveling wave readout pulse from the sample. The grating phase, measured with respect to a vibrationally stabilized inertial reference frame, scales as 2kgΤ2. A drawback of echo AIs is the signal-to-noise ratio, which is limited by the contrast of the grating and systematic effects due the refractive index of the sample. Here, we review improvements to the experimental design and investigate methods of improving the signal-to-noise ratio by optimizing the atom-field coupling. We describe progress toward realizing our goals of increasing the grating contrast and the backscattered signal. The improved contrast is expected to allow the experiment to be carried out at a lower density to reduce corrections due to the refractive index. We discuss a variety of excitation schemes for achieving a target precision of a few ppb.
We have studied the effects of spontaneous emission (SE) on a single-state time domain atom interferometer (AI) that uses trapped Rb atoms. The AI uses two standing wave pulses separated by time TTT to produce an echo signal at time 2T2T2T due to interference between momentum states. We find that SE influences both the shape of the echo signal and its periodic time-dependent amplitude in a manner consistent with theoretical predictions. The results show that the time-dependent signal from the AI is related to the effective radiative decay rate of the excited state. We also present results that test theoretical predictions for several properties of the echo formation such as the variation in momentum transfer due to the change in the angle between the traveling wave components of the excitation pulses, strength of the atom-field interaction, and the effect of spatial profile of the excitation beams. These studies are important for realizing precision measurements of the atomic fine structure constant and gravity using this interferometer.
We have studied the effects of spontaneous emission (SE) on a single-state time domain atom interferometer (AI) that uses trapped Rb atoms. The AI uses two standing wave pulses separated by time TTT to produce an echo signal at time 2T2T2T due to interference between momentum states. We find that SE influences both the shape of the echo signal and its periodic time-dependent amplitude in a manner consistent with theoretical predictions. The results show that the time-dependent signal from the AI is related to the effective radiative decay rate of the excited state. We also present results that test theoretical predictions for several properties of the echo formation such as the variation in momentum transfer due to the change in the angle between the traveling wave components of the excitation pulses, strength of the atom-field interaction, and the effect of spatial profile of the excitation beams. These studies are important for realizing precision measurements of the atomic fine structure constant and gravity using this interferometer.
A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.