Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Localization of a Three-Level Cascade Atom via Resonant Absorption

Wen-bing Shen, Jun Xu, Xiangming Hu

Published Aug 23, 2007• 7 citations
Publisher

Abstract

We show that it is possible to localize a three-level cascade atom under the resonance condition when it passes through a standing-wave field. The localization peaks appear at the nodes of the standing-wave field, the detecting probability is 50% in the subwavelength domain, and the peaks are narrower on the resonance than the off-resonance. The absorption is the same as that in the usual two-level medium at the nodes and is greatly suppressed outside the nodes due to the Autler–Townes splitting. This is in sharp contrast to the lambda scheme, in which the localization is impossible under the same resonance condition due to the depletion of population of the initial state by the probe field at the nodes and the electromagnetically induced transparency outside the nodes.

DOI
10.1088/0256-307x/24/9/033

Related papers

Subwavelength atom localization via amplitude and phase control of the absorption spectrum

Mostafa Sahrai, H. Tajalli, Kishore T. Kapale +1 more

We propose a scheme for subwavelength localization of an atom conditioned upon the absorption of a weak probe field at a particular frequency. Manipulating atom-field interaction on a certain transition by applying drive fields on nearby coupled transitions leads to interesting effects in the absorption spectrum of the weak probe field. We exploit this fact and employ a four-level system with three driving fields and a weak probe field, where one of the drive fields is a standing-wave field of a cavity. We show that the position of an atom along this standing wave is determined when probe-field absorption is measured. We find that absorption of the weak probe field at a certain frequency leads to subwavelength localization of the atom in either of the two half-wavelength regions of the cavity field by appropriate choice of the system parameters. We term this result as sub-half-wavelength localization to contrast it with the usual atom localization result of four peaks spread over one wavelength of the standing wave. We observe two localization peaks in either of the two half-wavelength regions along the cavity axis.

arXiv:quant-ph/0502158•Physical Review A•Jul 25, 2005•218 citations

SPECTROSCOPIC TECHNIQUES FOR SINGLE ATOM LOCALIZATION

Sajid, Qamar

Entanglement of the atom and field leads towards the measurement of the state of the atom or field depending on the kind of measurement made. Taking advantage of this fact, we propose spectroscopic methods for the single atom localization within the subwavelength domain of the optical standing wave field. \n \nWhen a two-level atom interacts with some intense radiation field the spectrum of the scattered light signal exhibits a three-peak Mollow spectrum. We propose a scheme of atom localization based on the resonance fluorescence from a two-level atom interacting with a standing wave field. The Rabi frequency is considered to be position dependent and therefore, the spontaneously emitted photon carries the information about the center-of-mass motion of the atom. This leads to the localization of the single atom by measuring the frequency of the spontaneously emitted photon even during the passage of the atom through the standing wave field. We predict a spatial resolution in position information of up to λ/60 where λ is the optical wavelength. \n \nDetuning of the coherent field with the atomic transition plays an important role in the characterization of the peaks present in the Autler- Townes spectrum of a three-level atom. Strong line narrowing is observed in one of the peaks of the Autler- Townes doublet depending on the choice of the detuning. We investigate how this detuning effects the position information of the atom inside the standing wave field in upper-level and lower-level coupling schemes of Autler- Townes microscopy. We show an enhancement in precision position measurement by factor of at least 4 in upper-level coupling scheme due to the quantum interference phenomenon. This enhancement is not observed in lower-level coupling scheme where the quantum interference is not taking place. \n \nWe also consider a system where a three-level atom is interacting with a monochromatic radiation field in such a way that the decay takes place from upper level to the intermediate level with a rate T and from intermediate level to lower level at a rate γ. This type of system exhibits a non stationary scattered light signal. We report the results of the spontaneous emission spectrum for non stationary scattered light signal by using the definition of time-dependent physical spectrum. This is a rare example of problems where time-dependent physical spectrum can be calculated exactly. We study the characteristics of the spontaneous spectrum for a resonant and off-resonant case and show that this physical spectrum recovers the results of earlier work quite successfully. We also show that the decay rate r disturbs the atomic coherence and finally eliminates the dark line from the center of the spontaneous spectrum. Here we only consider upper-level coupling case for the time-dependent spontaneous spectrum because in lower-level coupling case the system automatically evolved a pumping mechanism due to the coupling of ground level to the upper level via radiation field. Thus a steady-state limit exists in lower-level coupling scheme. \n \nWe investigate the phenomenon of atom localization by using the non stationary Autler-Townes microscopy. The decay rate T reduces the precision in position measurement which is consistent with the results of the non stationary spontaneous emission spectrum. This is due to the fact that for the upper-level coupling case, the standing wave field is coupled to atomic transition and it induces a coherence in the upper-level atomic transition but the spontaneous decay from the upper level to the intermediate level disturbs this coherence. When the effect of the spontaneous decay dominates the coherence effect the quantum interference phenomenon vanishes and thus the precision in localization reduces.

•Jan 1, 2000•0 citations

High-efficiency one-dimensional atom localization via two parallel standing-wave fields

Zhiping Wang, Xuqiang Wu, Liang Lü +1 more

We present a new scheme of high-efficiency one-dimensional (1D) atom localization via measurement of upper state population or the probe absorption in a four-level N-type atomic system. By applying two classical standing-wave fields, the localization peak position and number, as well as the conditional position probability, can be easily controlled by the system parameters, and the sub-half-wavelength atom localization is also observed. More importantly, there is 100% detecting probability of the atom in the subwavelength domain when the corresponding conditions are satisfied. The proposed scheme may open up a promising way to achieve high-precision and high-efficiency 1D atom localization.

Laser Physics•Aug 5, 2014•13 citations

Superposition of Stationary Wave Fields Via Atom Microscopy

Hizbullah, Ali khan Anwar, Khan Naveed +2 more

Abstract We investigate one-dimensional position microscopy of a three-level atom moving through a stationary wave region under the condition of electromagnetically induced transparency. The precise position information of an atom is observed on the resonance absorption and dispersion distribution spectrum of a weak probe field. Single and multiple localization peaks are observed in specific directions of the corresponding wave numbers and phase of the standing wave fields. The strength of space-independent Rabi frequency reduces the position uncertainty in the localized peaks without disturbing the probability of the atom. In a hot atomic medium the localized probability of an atom is reduced which depends upon the temperature of that medium. Our results provide useful applications in the development of laser cooling, atom nanolithography and Bose–Einstein condensation.

Communications in Theoretical Physics•Mar 1, 2015•3 citations

Sub-Half-Wavelength Atom Localization Based on Phase-Dependent Electromagnetically Induced Transparency

Gong Cheng, Xiangming Hu, Yandong Peng

We present a realistic and efficient scheme for sub-half-wavelength atom localization. This scheme is based on the phase-dependent electromagnetically induced transparency in a four-level system in the double-Λ configuration. We use a strong bichromatic field (one component of which is standing-wave field) as the driving components, and a weak bichromatic field as the probe components. By choosing the collective phase of the four applied components, the atom is localized in either of the two half-wavelength regions with 50% detecting probability when the absorption to the probe fields is detected.

Chinese Physics Letters•Feb 1, 2008•6 citations

Precise localization of a two-level atom by the superposition of two standing-wave fields

Bibhas Kumar Dutta, Pradipta Panchadhyayee, P.K. Mahapatra

A scheme is proposed to achieve one-dimensional localization of a two-level atom moving through a standing wave regime constructed by two classical standing-wave fields. Precise position information of the atom can be obtained by measuring resonant absorption of a weak coherent field probing the transition strongly driven by the resonant standing-wave fields. Behavior of atomic localization has been shown for symmetric superposition of the standing-wave fields arranged in two distinct configurations: (i) parallel and (ii) cross. In the cross-configuration, we have shown 100% detection probability of the atom within one wavelength range with the evolution of single localization peak in the sub-half-wavelength range due to the variation of spatial phase shift of one of the standing-wave fields. In case of nonresonant coupling of the atom with the standing-wave fields, a single localization peak in the sub-half-wavelength range can be obtained by changing the relative detuning of frequency of the probe field. For achieving high resolution single-peak localization of a two-level atom, the present scheme would be of great interest from the experimental point of view.

Journal of the Optical Society of America B•Nov 16, 2012•28 citations
We show that it is possible to localize a three-level cascade atom under the resonance condition when it passes through a standing-wave field. The localization peaks appear at the nodes of the standing-wave field, the detecting probability is 50% in the subwavelength domain, and the peaks are narrower on the resonance than the off-resonance. The absorption is the same as that in the usual two-level medium at the nodes and is greatly suppressed outside the nodes due to the Autler–Townes splitting. This is in sharp contrast to the lambda scheme, in which the localization is impossible under the same resonance condition due to the depletion of population of the initial state by the probe field at the nodes and the electromagnetically induced transparency outside the nodes.
We propose a scheme for subwavelength localization of an atom conditioned upon the absorption of a weak probe field at a particular frequency. Manipulating atom-field interaction on a certain transition by applying drive fields on nearby coupled transitions leads to interesting effects in the absorption spectrum of the weak probe field. We exploit this fact and employ a four-level system with three driving fields and a weak probe field, where one of the drive fields is a standing-wave field of a cavity. We show that the position of an atom along this standing wave is determined when probe-field absorption is measured. We find that absorption of the weak probe field at a certain frequency leads to subwavelength localization of the atom in either of the two half-wavelength regions of the cavity field by appropriate choice of the system parameters. We term this result as sub-half-wavelength localization to contrast it with the usual atom localization result of four peaks spread over one wavelength of the standing wave. We observe two localization peaks in either of the two half-wavelength regions along the cavity axis.
Entanglement of the atom and field leads towards the measurement of the state of the atom or field depending on the kind of measurement made. Taking advantage of this fact, we propose spectroscopic methods for the single atom localization within the subwavelength domain of the optical standing wave field. \n \nWhen a two-level atom interacts with some intense radiation field the spectrum of the scattered light signal exhibits a three-peak Mollow spectrum. We propose a scheme of atom localization based on the resonance fluorescence from a two-level atom interacting with a standing wave field. The Rabi frequency is considered to be position dependent and therefore, the spontaneously emitted photon carries the information about the center-of-mass motion of the atom. This leads to the localization of the single atom by measuring the frequency of the spontaneously emitted photon even during the passage of the atom through the standing wave field. We predict a spatial resolution in position information of up to λ/60 where λ is the optical wavelength. \n \nDetuning of the coherent field with the atomic transition plays an important role in the characterization of the peaks present in the Autler- Townes spectrum of a three-level atom. Strong line narrowing is observed in one of the peaks of the Autler- Townes doublet depending on the choice of the detuning. We investigate how this detuning effects the position information of the atom inside the standing wave field in upper-level and lower-level coupling schemes of Autler- Townes microscopy. We show an enhancement in precision position measurement by factor of at least 4 in upper-level coupling scheme due to the quantum interference phenomenon. This enhancement is not observed in lower-level coupling scheme where the quantum interference is not taking place. \n \nWe also consider a system where a three-level atom is interacting with a monochromatic radiation field in such a way that the decay takes place from upper level to the intermediate level with a rate T and from intermediate level to lower level at a rate γ. This type of system exhibits a non stationary scattered light signal. We report the results of the spontaneous emission spectrum for non stationary scattered light signal by using the definition of time-dependent physical spectrum. This is a rare example of problems where time-dependent physical spectrum can be calculated exactly. We study the characteristics of the spontaneous spectrum for a resonant and off-resonant case and show that this physical spectrum recovers the results of earlier work quite successfully. We also show that the decay rate r disturbs the atomic coherence and finally eliminates the dark line from the center of the spontaneous spectrum. Here we only consider upper-level coupling case for the time-dependent spontaneous spectrum because in lower-level coupling case the system automatically evolved a pumping mechanism due to the coupling of ground level to the upper level via radiation field. Thus a steady-state limit exists in lower-level coupling scheme. \n \nWe investigate the phenomenon of atom localization by using the non stationary Autler-Townes microscopy. The decay rate T reduces the precision in position measurement which is consistent with the results of the non stationary spontaneous emission spectrum. This is due to the fact that for the upper-level coupling case, the standing wave field is coupled to atomic transition and it induces a coherence in the upper-level atomic transition but the spontaneous decay from the upper level to the intermediate level disturbs this coherence. When the effect of the spontaneous decay dominates the coherence effect the quantum interference phenomenon vanishes and thus the precision in localization reduces.
We present a new scheme of high-efficiency one-dimensional (1D) atom localization via measurement of upper state population or the probe absorption in a four-level N-type atomic system. By applying two classical standing-wave fields, the localization peak position and number, as well as the conditional position probability, can be easily controlled by the system parameters, and the sub-half-wavelength atom localization is also observed. More importantly, there is 100% detecting probability of the atom in the subwavelength domain when the corresponding conditions are satisfied. The proposed scheme may open up a promising way to achieve high-precision and high-efficiency 1D atom localization.
Abstract We investigate one-dimensional position microscopy of a three-level atom moving through a stationary wave region under the condition of electromagnetically induced transparency. The precise position information of an atom is observed on the resonance absorption and dispersion distribution spectrum of a weak probe field. Single and multiple localization peaks are observed in specific directions of the corresponding wave numbers and phase of the standing wave fields. The strength of space-independent Rabi frequency reduces the position uncertainty in the localized peaks without disturbing the probability of the atom. In a hot atomic medium the localized probability of an atom is reduced which depends upon the temperature of that medium. Our results provide useful applications in the development of laser cooling, atom nanolithography and Bose–Einstein condensation.
We present a realistic and efficient scheme for sub-half-wavelength atom localization. This scheme is based on the phase-dependent electromagnetically induced transparency in a four-level system in the double-Λ configuration. We use a strong bichromatic field (one component of which is standing-wave field) as the driving components, and a weak bichromatic field as the probe components. By choosing the collective phase of the four applied components, the atom is localized in either of the two half-wavelength regions with 50% detecting probability when the absorption to the probe fields is detected.
A scheme is proposed to achieve one-dimensional localization of a two-level atom moving through a standing wave regime constructed by two classical standing-wave fields. Precise position information of the atom can be obtained by measuring resonant absorption of a weak coherent field probing the transition strongly driven by the resonant standing-wave fields. Behavior of atomic localization has been shown for symmetric superposition of the standing-wave fields arranged in two distinct configurations: (i) parallel and (ii) cross. In the cross-configuration, we have shown 100% detection probability of the atom within one wavelength range with the evolution of single localization peak in the sub-half-wavelength range due to the variation of spatial phase shift of one of the standing-wave fields. In case of nonresonant coupling of the atom with the standing-wave fields, a single localization peak in the sub-half-wavelength range can be obtained by changing the relative detuning of frequency of the probe field. For achieving high resolution single-peak localization of a two-level atom, the present scheme would be of great interest from the experimental point of view.