Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Time-of-flight neutron interferometry

H. Rauch, H. Wölwitsch, R. Clothier, Helmut Kaiser, S. A. Werner

Published Jul 1, 1992• 21 citations
Publisher

Abstract

In the experiment described in this paper, a chopper serves as a source of neutron intensity pulses which pass through a perfect Si-crystal neutron interferometer (NI), where they are split coherently into two parts that recombine and interfere. As the occupation number of a single pulse is much smaller than unity, the results very clearly demonstrate the single-particle interference phenomena of neutron interferometry experiments. While traveling the pulses spread, with faster (slower) neutrons tending toward the leading (trailing) edge. The coherence length of the neutrons depends on the spectral width of their wavelength distribution. When a material with a neutron-nuclear optical potential is placed in one beam path in the NI, there is a loss of fringe visibility (contrast), which depends on the coherence length. By using time-of-flight techniques, we divide the pulse into time segments. Within a given time slice, the wavelength spectrum is narrower than in the pulse as a whole. As a result, contrast remains in the time slices even when it disappears in the overall pulse. We also observe an additional contrast modulation due to the overlap of neighboring pulses.

DOI
10.1103/physreva.46.49

Related papers

Coherence and spectral filtering in neutron interferometry

Helmut Kaiser, R. Clothier, S. A. Werner +2 more

The coherence length of a neutron wave packet depends on the spectral width of the distribution of wave vectors that make up the packet. The coherent overlap of the wave packets traversing the two beam paths in a perfect-silicon-crystal neutron interferometer (NI) is altered by placing a material with a neutron-nuclear optical potential in one of the beam paths in the NI. If the optical potential is positive, it causes a delay of the wave packet and a loss of fringe visibility. By use of an analyzer crystal, we narrow the spectral distribution after the mixing and interference has occurred in the last crystal slab of the NI. This increases the coherence length and restores some of the fringe visibility.

Physical Review A•Jan 1, 1992•65 citations

Neutron interferometers and apparatus

Helmut Rauch, Samuel A. Werner

Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).

•Aug 10, 2000•0 citations

Spectral filtering in neutron interferometry

S. A. Werner, R. Clothier, Helmut Kaiser +2 more

We have demonstrated experimentally that the contrast lost, due to placing slabs of a material having a neutron optical potential in one leg of a neutron interferometer, can be restored by spectral filtering of the beams leaving the interferometer immediately before detection. The non-Gaussian spectral distribution of the neutrons traversing the interferometer in our experiment leads to an unexpected phase reversal of the interferograms.

Physical Review Letters•Aug 5, 1991•33 citations

Direct Measurement of the Longitudinal Coherence Length of a Thermal Neutron Beam

Helmut Kaiser, S. Werner, E. A. George

When a series of aluminum slabs are placed in one leg of a perfect-silicon-crystal neutron interferometer, a continuous and significant loss of contrast is observed. This observation is interpreted as being due to the finite length of the neutron wave packets.

Physical Review Letters•Feb 21, 1983•124 citations

Neutron phase echo

R. Clothier, Helmut Kaiser, S. A. Werner +2 more

The coherent overlap of the waves traversing the two legs of a perfect-crystal neutron interferometer is altered by a material with a neutron-nuclear optical potential. The fringe visibility is limited by the longitudinal coherence length. The loss of interference contrast caused by a slab of material of positive optical potential can be restored by placing another slab of material with a negative optical potential in the same leg of the interferometer. This paper describes the observation and detailed characterization of this quantum-mechanical phenomenon, which we call the phase-echo effect.

Physical Review A•Nov 1, 1991•47 citations

Far-field interference of a neutron white beam and the applications to noninvasive phase-contrast imaging

Dmitry A. Pushin, Dusan Sarenac, Daniel Seth Hussey +10 more

The phenomenon of interference plays a crucial role in the field of precision measurement science. Wave-particle duality has expanded the well-known interference effects of electromagnetic waves to massive particles. The majority of the wave-particle interference experiments require a near monochromatic beam which limits its applications due to the resulting low intensity. Here we demonstrate white beam interference in the far-field regime using a two-phase-grating neutron interferometer and its application to phase-contrast imaging. The functionality of this interferometer is based on the universal moir\'e effect that allows us to improve upon the standard Lau setup. Interference fringes were observed with monochromatic and polychromatic neutron beams for both continuous and pulsed beams. Far-field neutron interferometry allows for the full utilization of intense neutron sources for precision measurements of gradient fields. It also overcomes the alignment, stability, and fabrication challenges associated with the more familiar perfect-crystal neutron interferometer, as well as avoids the loss of intensity due to the absorption analyzer grating requirement in Talbot-Lau interferometer.

arXiv:1606.03445•Physical Review A•Apr 26, 2017•41 citations
In the experiment described in this paper, a chopper serves as a source of neutron intensity pulses which pass through a perfect Si-crystal neutron interferometer (NI), where they are split coherently into two parts that recombine and interfere. As the occupation number of a single pulse is much smaller than unity, the results very clearly demonstrate the single-particle interference phenomena of neutron interferometry experiments. While traveling the pulses spread, with faster (slower) neutrons tending toward the leading (trailing) edge. The coherence length of the neutrons depends on the spectral width of their wavelength distribution. When a material with a neutron-nuclear optical potential is placed in one beam path in the NI, there is a loss of fringe visibility (contrast), which depends on the coherence length. By using time-of-flight techniques, we divide the pulse into time segments. Within a given time slice, the wavelength spectrum is narrower than in the pulse as a whole. As a result, contrast remains in the time slices even when it disappears in the overall pulse. We also observe an additional contrast modulation due to the overlap of neighboring pulses.
The coherence length of a neutron wave packet depends on the spectral width of the distribution of wave vectors that make up the packet. The coherent overlap of the wave packets traversing the two beam paths in a perfect-silicon-crystal neutron interferometer (NI) is altered by placing a material with a neutron-nuclear optical potential in one of the beam paths in the NI. If the optical potential is positive, it causes a delay of the wave packet and a loss of fringe visibility. By use of an analyzer crystal, we narrow the spectral distribution after the mixing and interference has occurred in the last crystal slab of the NI. This increases the coherence length and restores some of the fringe visibility.
Abstract Among the various areas of neutron optical research, neutron interferometry has provided some of the most challenging and spectacular developments. In most cases, separated coherent beams are used which are produced either by wavefront division (Young’s type) or by amplitude division (Mach− Zehnder type). These beams are subsequently coherently superposed after passing through regions of space where the neutron wavefunction is modified in phase and amplitude by various interactions: nuclear, magnetic, electromagnetic, gravitational, or by geometry and topology (as in Aharonov−Bohm-type experiments). Various types of neutron interferometers that have been tested are shown in Fig. 2.1. The first neutron interferometer was based upon wavefront division and biprism deflection, but it had several constraints for interferometric applications mainly due to the small beam separation (100 μm) (Maier-Leibnitz and Springer 1962). Nevertheless, this method gained further interest for diffraction experiments from macroscopic objects and for the detection of weak interaction effects where the long flight paths (10 m) enhance the sensitivity for the measurements of these effects (Gähler et al. 1980; Klein et al. 1981a). The perfect-crystal interferometer (Rauch et al. 1974) provides widely separated coherent beams and has become a standard method for advanced neutron optical investigations. The development of diffraction and phase grating interferometers extended the Mach-Zehnder interferometer method to very slow neutrons (loffe et al. 1985; Gruber et al. 1989). The superposition of spin-up and spin-down states in the longitudinal direction provides the basis for Larmor and Ramsey interferometry, where no lateral beam splitting is necessary. The well-known spin-echo systems (Mezei 1972) and zero-field spin-echo systems (Gähler and Golub 1987; Dubbers et al. 1989) are examples of such interferometers, which also play an important role in atom interferometry (Bord é 1989; Kasevich and Chu 1991; Riehle et al. 1991).
The coherent overlap of the waves traversing the two legs of a perfect-crystal neutron interferometer is altered by a material with a neutron-nuclear optical potential. The fringe visibility is limited by the longitudinal coherence length. The loss of interference contrast caused by a slab of material of positive optical potential can be restored by placing another slab of material with a negative optical potential in the same leg of the interferometer. This paper describes the observation and detailed characterization of this quantum-mechanical phenomenon, which we call the phase-echo effect.
The phenomenon of interference plays a crucial role in the field of precision measurement science. Wave-particle duality has expanded the well-known interference effects of electromagnetic waves to massive particles. The majority of the wave-particle interference experiments require a near monochromatic beam which limits its applications due to the resulting low intensity. Here we demonstrate white beam interference in the far-field regime using a two-phase-grating neutron interferometer and its application to phase-contrast imaging. The functionality of this interferometer is based on the universal moir\'e effect that allows us to improve upon the standard Lau setup. Interference fringes were observed with monochromatic and polychromatic neutron beams for both continuous and pulsed beams. Far-field neutron interferometry allows for the full utilization of intense neutron sources for precision measurements of gradient fields. It also overcomes the alignment, stability, and fabrication challenges associated with the more familiar perfect-crystal neutron interferometer, as well as avoids the loss of intensity due to the absorption analyzer grating requirement in Talbot-Lau interferometer.