European Microwave Conference (EuMC)
Noise Temperature and Absorbed LO Power Measurement Methods for NbN Phonon-Cooled Hot Electron Bolometric Mixers at Terahertz Frequencies
Harald F. Merkel, Pavel A. Yagoubov, M. Kroug, P. Khosropanah, E. Kollberg, Gregory N Gol'tsman, Eugene M. Gershenzon
Abstract
In this paper the absorbed LO power requirements and the noise performance of NbN based phonon-cooled hot electron bolometric (HEB) quasioptical mixers are investigated for RF frequencies in the 0.55-1.1 range The minimal measured DSB noise temperatures are about 500 K at 640 GHz, 600 K at 750 GHz, 850 K at 910 GHz and 1250 K at 1.1 THz. The increase in noise temperature at 1.1THz is attributed to water absorption. The absorbed LO power is measured using a calorimetric approach. The results are subsequently corrected for lattice heating. These values are compared to results of a novel one dimensional hot spot mixer models and to a more traditional isotherm method which tends to underestimate the absorbed LO power for small bias powers. Typically a LO power between 50nW and 100nW is needed to pump the device to the optimal operating point.