Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chemical Physics Letters

Coherent fluorescence resonance energy transfer in symmetrical clusters of fluorescent centers

Irina Basieva, Sergey K. Sekatskii, Giovanni Dietler

Published Jan 7, 2005• 2 citations
Publisher
DOI
10.1016/j.cplett.2004.12.048

Related papers

Coherent Cooperative Fluorescence Resonance Energy Transfer

Sergey K. Sekatskii, Konstantin K. Pukhov

Оптика и спектроскопия•Jan 1, 2014•0 citations

Fluorescence resonance energy transfer and quantum Zeno effect

Sergey K. Sekatskii

Physics Letters A•Sep 16, 2003•4 citations

Coherent cooperative fluorescence resonance energy transfer

Sergey K. Sekatskii, Konstantin K. Pukhov

Cooperative fluorescence resonance energy transfer effect is experimentally demonstrated for a few crystals doped with rare-earth ions. We show that, at the liquid helium temperatures in similar crystals, coherent cooperative fluorescence resonance energy transfer, as well as an inverse coherent up-conversion process, could be observed, and briefly discuss possible applications of these effects.

Optics and Spectroscopy•Dec 1, 2014•1 citation

Nonstationary cooperative phenomena in resonance fluorescence

Sergey G. Rautian, B. M. Chernobrod

Journal of Experimental and Theoretical Physics•Oct 1, 1981•0 citations

FRET Between NV Centers In Diamond And Chlorophyll Molecules: A Novel Resource For Multimodal Sensing And Imaging In Plant Cells

Sebastian Westrich, Nimba Oshnik, Nina D. Thiele +5 more

ABSTRACT This work demonstrates efficient Förster resonance energy transfer (FRET) between ensembles of shallow nitrogen‐vacancy (NV) centers located and below a single‐crystal diamond surface and a naturally occurring fluorophore, here a mixture of chlorophyll a and b molecules extracted from Arabidopsis thaliana . The broad fluorescence band of NV centers spectrally overlaps with the chlorophyll molecule's absorption, enabling FRET. Consequently, depositing a chlorophyll layer on the diamond surface reduces the NV fluorescence lifetime from approximately to below , indicating efficient FRET. Laser‐induced photobleaching of chlorophyll restores the unquenched NV lifetime. NV centers located deeper within the diamond ( and ) remain unaffected, confirming that the observed quenching originates from a short range FRET mechanism. The NV ensembles retain their optically detected magnetic resonance (ODMR) contrast while observing FRET, demonstrating preservation of their spin properties. Consequently, these proof‐of‐principle experiments demonstrate the feasibility of combining FRET‐based distance measurements with magnetic sensing using optically readable spins.

Advanced Optical Materials•Apr 1, 2026•0 citations

Theoretical Study of Single-Pair Fluorescence Resonant Energy Transfer Spectroscopy in Microcavity

单光存 Shan Guangcun, 黄维 Huang Wei

Acta Optica Sinica•Jan 1, 2009•2 citations
ABSTRACT This work demonstrates efficient Förster resonance energy transfer (FRET) between ensembles of shallow nitrogen‐vacancy (NV) centers located and below a single‐crystal diamond surface and a naturally occurring fluorophore, here a mixture of chlorophyll a and b molecules extracted from Arabidopsis thaliana . The broad fluorescence band of NV centers spectrally overlaps with the chlorophyll molecule's absorption, enabling FRET. Consequently, depositing a chlorophyll layer on the diamond surface reduces the NV fluorescence lifetime from approximately to below , indicating efficient FRET. Laser‐induced photobleaching of chlorophyll restores the unquenched NV lifetime. NV centers located deeper within the diamond ( and ) remain unaffected, confirming that the observed quenching originates from a short range FRET mechanism. The NV ensembles retain their optically detected magnetic resonance (ODMR) contrast while observing FRET, demonstrating preservation of their spin properties. Consequently, these proof‐of‐principle experiments demonstrate the feasibility of combining FRET‐based distance measurements with magnetic sensing using optically readable spins.