Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

A cesium resonance fluorescence imaging monochromator

Dimitri Pappas, Nathan C. Pixley, Oleg I. Matveev, Benjamin W. Smith, James D. Winefordner

Published May 1, 2001• 16 citations
Publisher
DOI
10.1016/s0030-4018(01)01124-5

Related papers

Moving object detection using a cesium resonance fluorescence monochromator

Nathan C. Pixley, Tiffany L. Correll, Dimitri Pappas +3 more

Optics Communications•Apr 1, 2003•6 citations

Time and energy characteristics of an atomic-resonance fluorescence filter working with cesium vapor

А. В. Белинский, M. G. Dubenskaya, Alexey A Podshivalov

Journal of Applied Spectroscopy•Jul 1, 1992•0 citations

Imaging atoms from resonance fluorescence spectrum beyond the diffraction limit

Zeyang Liao, M. Al-Amri, Muhammad Suhail Zubairy

Bulletin of the American Physical Society•Mar 7, 2014•0 citations

A resonance ionization imaging detector based on cesium atomic vapor

J. P. Temirov, Nikolay Chigarev, Oleg I. Matveev +3 more

Spectrochimica Acta Part B Atomic Spectroscopy•May 1, 2004•13 citations

Sub-Doppler Spectral Resolution and Improved Sensitivity in a Cesium Resonance Fluorescence Imaging Monochromator

Nathan C. Pixley, Tiffany L. Correll, Dimitri Pappas +2 more

Improvements in spectral resolution and sensitivity of a cesium based resonance fluorescence imaging monochromator (RFIM) are described. Alignment of the two lasers used in the excitation scheme in a co-propagating geometry have resulted in a detector spectral bandpass (270 MHz) that is narrower than the Doppler broadened profile (380 MHz) of cesium vapor at room temperature. Improvements in the experimental design, namely the addition of an image intensifier and cooled charge-coupled device (CCD) camera, have resulted in increased sensitivity; we report a limit of detection of 10 8 photons per pixel limited by image intensifier noise. Images of the cesium D 2 line emission (852.12 nm) from a cesium hollow cathode lamp were compared to an argon emission line (4Sº 1/2 → 4P 3/2 ) at 852.14 nm from a silver/argon hollow cathode lamp as a demonstration of the spectral resolution. The ability of the RFIM to discriminate between photons exciting the F = 4 vs. F = 3 ground state hyperfine level (a frequency difference of 9.2 GHz) of the cesium 6 2 S 1/2 state was also investigated to further demonstrate the spectral selectivity. The potential use of the described RFIM for chemical imaging applications is discussed.

Applied Spectroscopy•Jun 1, 2002•10 citations

Resonance Fluorescence

Miguel Orszag

Springer eBooks•Jan 1, 2000•0 citations
Improvements in spectral resolution and sensitivity of a cesium based resonance fluorescence imaging monochromator (RFIM) are described. Alignment of the two lasers used in the excitation scheme in a co-propagating geometry have resulted in a detector spectral bandpass (270 MHz) that is narrower than the Doppler broadened profile (380 MHz) of cesium vapor at room temperature. Improvements in the experimental design, namely the addition of an image intensifier and cooled charge-coupled device (CCD) camera, have resulted in increased sensitivity; we report a limit of detection of 10 8 photons per pixel limited by image intensifier noise. Images of the cesium D 2 line emission (852.12 nm) from a cesium hollow cathode lamp were compared to an argon emission line (4Sº 1/2 → 4P 3/2 ) at 852.14 nm from a silver/argon hollow cathode lamp as a demonstration of the spectral resolution. The ability of the RFIM to discriminate between photons exciting the F = 4 vs. F = 3 ground state hyperfine level (a frequency difference of 9.2 GHz) of the cesium 6 2 S 1/2 state was also investigated to further demonstrate the spectral selectivity. The potential use of the described RFIM for chemical imaging applications is discussed.