Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Europhysics Letters (EPL)

Ultra thin coherent atom beam by Stern-Gerlach interferometry

F Perales, Jacques Robert, J. Baudon, M. Ducloy

Published May 24, 2007• 10 citations
Publisher

Abstract

It is demonstrated that a Stern-Gerlach interferometer including a special transverse phase shifter can generate an atomic beam of a small diameter (few tens of nm). Calculations carried out in a coherent regime confirm this point. They also show that the device is almost insensitive to velocity dispersion and that the required mechanical accuracy is quite accessible. Due to the peculiar transverse amplitude distribution (of the Lorentz type), the spreading of the generated beam profile is very small compared to that given by a circular diaphragm or a Gaussian profile of comparable initial diameter. This is a key property as regards applications, e.g . in atom lithography and surface probing.

DOI
10.1209/0295-5075/78/60003

Related papers

Longitudinal Stern-Gerlach atomic interferometry using velocity selected atomic beams

Síle Nic Chormaic, V. Wiedeman, Christian Miniatura +7 more

New experiments have been carried out on a velocity selected beam of H(D)*(2s 1 2/) atoms using a longitudinal Stern-Gerlach atomic interferometer. A large number of fringes of the interference pattern has been observed. The results are in good agreement with theoretical predictions. An application to a topological phaseshift of the Aharonov-Anandan type is given.

Journal of Physics B Atomic Molecular and Optical Physics•Apr 14, 1993•12 citations

Atomic Interferometry with Metastable Hydrogen Atoms

Jacques Robert, Christian Miniatura, S. Le Boiteux +3 more

An atomic interferometer using the longitudinal Stern-Gerlach effect has been constructed. A thermal beam of metastable hydrogen atoms has been used to test the apparatus. Interference patterns have been obtained. The visibility of the fringes is limited by the velocity spread of the beam. The observed patterns are in good agreement with that predicted from the actual velocity distribution.

Europhysics Letters (EPL)•Sep 1, 1991•50 citations

Atom interferometer using two Stern-Gerlach magnets

Kenneth H. Rubin, M. Eminyan, F Perales +8 more

An atom interferometer using two Stern-Gerlach magnets as polariser and analyser is described. The interferometer was first operated with a thermal beam of ground state potassium atoms. In that case the beam splitters are two radio-frequency zones within a transverse homogeneous magnetic field building a coherent superposition of Zeeman states. Ramsey fringes are obtained by scanning the RF-frequency through the resonance profile. Pulsing the RF power allows to get the time-of-flight distribution of the beam. Atomic interference fringes (``Stern-Gerlach fringes'') are observed when the magnitude of an inhomogeneous magnetic field located in between the beam splitters is scanned. When the inhomogeneous field is also pulsed, the scalar Bohm-Aharonov effect is observed. The use of metastable helium atoms (He*23S) in place of potassium atoms is proposed. In addition to the usual advantages provided by metastable atoms of high internal energy, this atom offers the specific advantage to behave as an ideal spin-one particle. This allows us to greatly simplify the polarisation scheme of the interferometer. Possible applications involving transversally inhomogeneous magnetic fields are given and limitations due to the finite source size and angular aperture are discussed.

Laser Physics Letters•Mar 9, 2004•12 citations

A longitudinal Stern-Gerlach interferometer : the “beaded” atom

Christian Miniatura, F. Perales, G. Vassilev +3 more

The principle on an atomic interferometer based on the longitudinal Stern-Gerlach effect is given. Possible realizations using beams of metastable rare gas atoms or metastable hydrogen atoms are described. Some examples of phase-objects are discussed and some possible applications are suggested. The atoms coming out of the interferometer exhibit uncommon properties, particulary a permanent multiple localisation regarding the external atomic variables (“beaded” atoms).

Journal de Physique II•Apr 1, 1991•20 citations

Stern-Gerlach Interferometry with the Atom Chip

Mark Keil, Shimon Machluf, Yair Margalit +12 more

Abstract In this invited review in honor of 100 years since the Stern-Gerlach (SG) experiments, we describe a decade of SG interferometry on the atom chip. The SG effect has been a paradigm of quantum mechanics throughout the last century, but there has been surprisingly little evidence that the original scheme, with freely propagating atoms exposed to gradients from macroscopic magnets, is a fully coherent quantum process. Specifically, no full-loop SG interferometer (SGI) has been realized with the scheme as envisioned decades ago. Furthermore, several theoretical studies have explained why it is a formidable challenge. Here we provide a review of our SG experiments over the last decade. We describe several novel configurations such as that giving rise to the first SG spatial interference fringes, and the first full-loop SGI realization. These devices are based on highly accurate magnetic fields, originating from an atom chip, that ensure coherent operation within strict constraints described by previous theoretical analyses. Achieving this high level of control over magnetic gradients is expected to facilitate technological applications such as probing of surfaces and currents, as well as metrology. Fundamental applications include the probing of the foundations of quantum theory, gravity, and the interface of quantum mechanics and gravity. We end with an outlook describing possible future experiments.

arXiv:2009.08112•Springer eBooks•Jan 1, 2021•17 citations

Realization of a complete Stern-Gerlach interferometer

Yair Margalit, Zhifan Zhou, Or Dobkowski +4 more

The Stern-Gerlach (SG) effect, discovered almost a century ago, has become a paradigm of quantum mechanics. Surprisingly there is little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Specifically, no high-visibility spatial interference pattern has been observed with such a scheme, and furthermore no full-loop SG interferometer has been realized with the scheme as envisioned decades ago. On the contrary, numerous theoretical studies explained why it is a near impossible endeavor. Here we demonstrate for the first time both a high-visibility spatial SG interference pattern and a full-loop SG interferometer, based on an accurate magnetic field, originating from an atom chip, that ensures coherent operation within strict constraints described by previous theoretical analyses. This also allows us to observe the gradual emergence of time-irreversibility as the splitting is increased. Finally, achieving this high level of control over magnetic gradients may facilitate technological applications such as large-momentum-transfer beam splitting for metrology with atom interferometry, ultra-sensitive probing of electron transport down to shot-noise and squeezed currents, as well as nuclear magnetic resonance and compact accelerators.

arXiv:1801.02708•Jan 8, 2018•35 citations
It is demonstrated that a Stern-Gerlach interferometer including a special transverse phase shifter can generate an atomic beam of a small diameter (few tens of nm). Calculations carried out in a coherent regime confirm this point. They also show that the device is almost insensitive to velocity dispersion and that the required mechanical accuracy is quite accessible. Due to the peculiar transverse amplitude distribution (of the Lorentz type), the spreading of the generated beam profile is very small compared to that given by a circular diaphragm or a Gaussian profile of comparable initial diameter. This is a key property as regards applications, e.g . in atom lithography and surface probing.
An atom interferometer using two Stern-Gerlach magnets as polariser and analyser is described. The interferometer was first operated with a thermal beam of ground state potassium atoms. In that case the beam splitters are two radio-frequency zones within a transverse homogeneous magnetic field building a coherent superposition of Zeeman states. Ramsey fringes are obtained by scanning the RF-frequency through the resonance profile. Pulsing the RF power allows to get the time-of-flight distribution of the beam. Atomic interference fringes (``Stern-Gerlach fringes'') are observed when the magnitude of an inhomogeneous magnetic field located in between the beam splitters is scanned. When the inhomogeneous field is also pulsed, the scalar Bohm-Aharonov effect is observed. The use of metastable helium atoms (He*23S) in place of potassium atoms is proposed. In addition to the usual advantages provided by metastable atoms of high internal energy, this atom offers the specific advantage to behave as an ideal spin-one particle. This allows us to greatly simplify the polarisation scheme of the interferometer. Possible applications involving transversally inhomogeneous magnetic fields are given and limitations due to the finite source size and angular aperture are discussed.
Abstract In this invited review in honor of 100 years since the Stern-Gerlach (SG) experiments, we describe a decade of SG interferometry on the atom chip. The SG effect has been a paradigm of quantum mechanics throughout the last century, but there has been surprisingly little evidence that the original scheme, with freely propagating atoms exposed to gradients from macroscopic magnets, is a fully coherent quantum process. Specifically, no full-loop SG interferometer (SGI) has been realized with the scheme as envisioned decades ago. Furthermore, several theoretical studies have explained why it is a formidable challenge. Here we provide a review of our SG experiments over the last decade. We describe several novel configurations such as that giving rise to the first SG spatial interference fringes, and the first full-loop SGI realization. These devices are based on highly accurate magnetic fields, originating from an atom chip, that ensure coherent operation within strict constraints described by previous theoretical analyses. Achieving this high level of control over magnetic gradients is expected to facilitate technological applications such as probing of surfaces and currents, as well as metrology. Fundamental applications include the probing of the foundations of quantum theory, gravity, and the interface of quantum mechanics and gravity. We end with an outlook describing possible future experiments.
The Stern-Gerlach (SG) effect, discovered almost a century ago, has become a paradigm of quantum mechanics. Surprisingly there is little evidence that the original scheme with freely propagating atoms exposed to gradients from macroscopic magnets is a fully coherent quantum process. Specifically, no high-visibility spatial interference pattern has been observed with such a scheme, and furthermore no full-loop SG interferometer has been realized with the scheme as envisioned decades ago. On the contrary, numerous theoretical studies explained why it is a near impossible endeavor. Here we demonstrate for the first time both a high-visibility spatial SG interference pattern and a full-loop SG interferometer, based on an accurate magnetic field, originating from an atom chip, that ensures coherent operation within strict constraints described by previous theoretical analyses. This also allows us to observe the gradual emergence of time-irreversibility as the splitting is increased. Finally, achieving this high level of control over magnetic gradients may facilitate technological applications such as large-momentum-transfer beam splitting for metrology with atom interferometry, ultra-sensitive probing of electron transport down to shot-noise and squeezed currents, as well as nuclear magnetic resonance and compact accelerators.