Physical Review Letters

Atomic Interferometry with the Micromaser

Georg A. Raithel, Oliver J. Benson, HERBERT WALTHER

Published Nov 6, 1995• 46 citations
Publisher

Abstract

Atomic interferences are observed in the micromaser when the inversion of the atoms leaving the cavity is measured while the cavity frequency is scanned across the atomic resonance. The interferences are due to the nonadiabatic mixing of dressed states at the entrance and exit holes of the maser cavity. The interference structures are triangular shaped and approximately equidistant. They are associated with the dynamics of the atom-field interaction, show quantum jumps, and demonstrate bistability of the micromaser field.

DOI
10.1103/physrevlett.75.3446

Related papers

Entanglement and superposition states in the micromaser

HERBERT WALTHER

In this paper recent experiments with the one–atom maser or micromaser are reviewed. They deal with the dynamical behavior of the field at parameter values where the field undergoes phase transitions. Furthermore, atomic interferences are observed in the micromaser when the inversion of the atoms leaving the cavity is measured while the cavity frequency is scanned across the atomic resonance. The interferences are due to the non–adiabatic mixing of dressed states at the entrance and exit holes of the maser cavity. The interference structures are triangular shaped and approximately equidistant. They are associated with the dynamics of the atom–field interaction, show quantum jumps and demonstrate bistability of the micromaser field.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Dec 15, 1997•1 citation

Atomic interference in the micromaser and statistical properties of the micromaser field

Oliver J. Benson, M. Weidinger, Georg A. Raithel +1 more

In this paper we report on atomic interferometry in the micromaser. The atomic inversion is recorded while scanning the cavity frequency across the atomic resonance. For high pump rates, interference patterns are observed on the low-frequency wing of the maser line. The interferences are due to the non-adiabatic mixing of dressed states of the atoms at the entrance and exit holes of the maser cavity, leading to a Ramsey-type two-field interaction. Furthermore, statistical properties of the maser field are investigated via a measurement of the statistics of the pump atoms that leave the maser cavity. Theoretical expressions for the time dependence of the Fano–Mandel parameter Q A(t) are compared with the experimental data. We demonstrate, that metastability of the maser field and atomic interference strongly influence the approach to a steady-state value of Q A(t).

Journal of Modern Optics•Oct 1, 1997•3 citations

From Maser to Mazer

Oliver J. Benson, M. Weidinger, Markus Löffler +1 more

In this paper we report on atomic interferometry in the micromaser. The experimentally observed interferences are due to the non-adiabatic mixing of dressed states of the atoms at the entrance and exit holes of the maser cavity, leading to Ramsey-type two-field interaction. The observations are explained on the basis of the micromaser theory. Statistical properties of the maser field are investigated via a measurement of the statistics of the pump atoms that leave the maser cavity. Theoretical expressions for the time dependence of the Fano-Mandel-parameter QA(t) are compared with the experimental data. We demonstrate, that metastability of the maser field and atomic interference strongly influence the approach to a steady state value of QA(t). Furthermore, a theoretical investigation of a maser pumped with ultra-cold atoms is discussed. The interplay between reflection and transmission events of the atoms leads to a photon emission probability that strongly depends on the quantized center-of-mass motion (z-motion) of the atoms. We demonstrate that this mazer operation can be completely different from the ordinary maser pumped by a beam of thermal atoms.

Fortschritte der Physik•Nov 1, 1998•3 citations

Trapping States in the Micromaser

M. Weidinger, Benjamin T. H. Varcoe, R. Heerlein +1 more

Trapping states in the one-atom maser or micromaser are predicted by maser theory and are a direct consequence of the quantization of the electromagnetic field. They have been found in our experiment when the inversion of atoms leaving the cavity is observed while the interaction time is scanned. They correspond to quantum states of the atom-cavity system and under certain conditions represent Fock states. The trapping states occur when the atom-field dynamics complete a full evolution (or multiples thereof). Owing to feedback through the maser dynamics, a stabilization of the photon number in the steady state field of the maser cavity is achieved.

Physical Review Letters•May 10, 1999•251 citations

Reflecting Slow Atoms from a Micromaser Field

Berthold‐Georg Englert, Julian Schwinger, A. O. Barut +1 more

Excited atoms incident upon the entrance port of a maser cavity will be reflected half of the time, if the atoms are slow enough, even when the maser field is in its vacuum state. This happens because the interaction strength, between the atom and the maser field, changes strongly when passing from the exterior to the interior of the cavity.

Europhysics Letters (EPL)•Jan 1, 1991•148 citations

Field statistics in the micromaser induced by a collective measurement

K. Vogel, V. M. Akulin, W. P. Schleich

We analyze a measurement strategy in which we first send N excited two-level atoms through a maser cavity and then measure the total excitation n of the atoms after their interaction with the maser field. In this case the field in the cavity after the measurement is governed by the quantum mechanical interference of probability amplitudes corresponding to all possible sequences of n excited and N − n de-excited atoms.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations
Atomic interferences are observed in the micromaser when the inversion of the atoms leaving the cavity is measured while the cavity frequency is scanned across the atomic resonance. The interferences are due to the nonadiabatic mixing of dressed states at the entrance and exit holes of the maser cavity. The interference structures are triangular shaped and approximately equidistant. They are associated with the dynamics of the atom-field interaction, show quantum jumps, and demonstrate bistability of the micromaser field.
In this paper recent experiments with the one–atom maser or micromaser are reviewed. They deal with the dynamical behavior of the field at parameter values where the field undergoes phase transitions. Furthermore, atomic interferences are observed in the micromaser when the inversion of the atoms leaving the cavity is measured while the cavity frequency is scanned across the atomic resonance. The interferences are due to the non–adiabatic mixing of dressed states at the entrance and exit holes of the maser cavity. The interference structures are triangular shaped and approximately equidistant. They are associated with the dynamics of the atom–field interaction, show quantum jumps and demonstrate bistability of the micromaser field.
In this paper we report on atomic interferometry in the micromaser. The atomic inversion is recorded while scanning the cavity frequency across the atomic resonance. For high pump rates, interference patterns are observed on the low-frequency wing of the maser line. The interferences are due to the non-adiabatic mixing of dressed states of the atoms at the entrance and exit holes of the maser cavity, leading to a Ramsey-type two-field interaction. Furthermore, statistical properties of the maser field are investigated via a measurement of the statistics of the pump atoms that leave the maser cavity. Theoretical expressions for the time dependence of the Fano–Mandel parameter Q A(t) are compared with the experimental data. We demonstrate, that metastability of the maser field and atomic interference strongly influence the approach to a steady-state value of Q A(t).
In this paper we report on atomic interferometry in the micromaser. The experimentally observed interferences are due to the non-adiabatic mixing of dressed states of the atoms at the entrance and exit holes of the maser cavity, leading to Ramsey-type two-field interaction. The observations are explained on the basis of the micromaser theory. Statistical properties of the maser field are investigated via a measurement of the statistics of the pump atoms that leave the maser cavity. Theoretical expressions for the time dependence of the Fano-Mandel-parameter QA(t) are compared with the experimental data. We demonstrate, that metastability of the maser field and atomic interference strongly influence the approach to a steady state value of QA(t). Furthermore, a theoretical investigation of a maser pumped with ultra-cold atoms is discussed. The interplay between reflection and transmission events of the atoms leads to a photon emission probability that strongly depends on the quantized center-of-mass motion (z-motion) of the atoms. We demonstrate that this mazer operation can be completely different from the ordinary maser pumped by a beam of thermal atoms.
Trapping states in the one-atom maser or micromaser are predicted by maser theory and are a direct consequence of the quantization of the electromagnetic field. They have been found in our experiment when the inversion of atoms leaving the cavity is observed while the interaction time is scanned. They correspond to quantum states of the atom-cavity system and under certain conditions represent Fock states. The trapping states occur when the atom-field dynamics complete a full evolution (or multiples thereof). Owing to feedback through the maser dynamics, a stabilization of the photon number in the steady state field of the maser cavity is achieved.