Journal of Experimental and Theoretical Physics Letters

Investigation of various operation modes of a miniature superconducting detector of microwave radiation

Igor A. Devyatov, П. А. Крутицкий, M. Yu. Kupriyanov

Published Sep 1, 2006• 18 citations
Publisher

Abstract

Nonequilibrium electron and phonon distribution functions have been calculated for a metallic absorber of a promising miniature superconducting detector irradiated by microwave radiation. The response of this detector has been calculated, and it has been shown that this detector can operate in either the photon counter mode or bolometric mode in dependence on the degree of nonequilibrium of the phonon subsystem.

DOI
10.1134/s0021364006140037

Related papers

Theoretical analysis of the operation of the kinetic inductance-based superconducting microwave detector

Alexander V. Semenov, Igor A. Devyatov, M. Yu. Kupriyanov

Nonequilibrium quasiparticle distribution functions that appear in a current-biased thin narrow diffuse superconducting strip under microwave irradiation at a low temperature have been calculated. A change in the kinetic inductance of the strip due to irradiation has been determined. The application of the strip as a microwave detector has been considered and the influence of the nonlinear phonon subsystem of the strip on the magnitude of the response has been found.

Journal of Experimental and Theoretical Physics Letters•Dec 1, 2008•6 citations

High-sensitivity microwave detector based on a Josephson heterostructure

Igor A. Devyatov, M. Yu. Kupriyanov

The possibility of using the Josephson heterostructure composed of a nanoscale metallic absorber separated from superconducting strips by thin insulating layers as a high-sensitivity microwave detector has been considered theoretically. The inductive response of such a detector has been calculated and the influence of the nonequilibrium of the electron subsystem of the metallic absorber on its response has been analyzed. The limiting sensitivity of the proposed detector has been found.

Journal of Experimental and Theoretical Physics Letters•Jul 1, 2009•1 citation

Microwave SINIS Detectors

Michael A. Tarasov, Aleksandra A. Gunbina, Artem M. Chekushkin +3 more

This review presents the main characteristics and mechanisms of operation of superconductor–insulator–normal metal–insulator–superconductor (SINIS) microwave detectors. An analysis of the detectors’ performance against a quantum detector and a photon counter is given. Methods for cooling a superconductor using normal metal traps and the role of electron cooling in optimizing the current response to terahertz radiation are discussed. Fabrication methods using shadow evaporation as well as magnetron sputtering are described.

Applied Sciences•Oct 18, 2022•11 citations

Physics of proximity Josephson sensor

J. Voutilainen, Matti A. Laakso, Tero Tapio Heikkilä

We study the proximity Josephson sensor in both bolometric and calorimetric operation and optimize it for different temperature ranges between 25 mK and a few kelvin. We investigate how the radiation power is absorbed in the sensor and find that the irradiated system is typically in a weak nonequilibrium state. We show in detail how the proximity of the superconductors affects the device response: for example, via changes in electron-phonon coupling and out-of-equilibrium noise. In addition, we estimate the applicability of graphene as the absorber material.

arXiv:0906.5470•Journal of Applied Physics•Mar 15, 2010•16 citations

Analysis of bolometer operation near the superconducting transition edge using microwave readout

Artem A. Kuzmin, S. V. Shitov, Alexey Vladimirovich Ustinov

The results of pioneering experiments on using a new method of microwave recording the bolometric response from a metal film near its superconducting transition edge are analyzed. Experiments are carried out at 4.5 K using a thin-film niobium absorber with a critical temperature of 6.7 K. The validity of the adopted electrodynamic model is confirmed. The chip contains a miniature antenna tuned to approximately 600 GHz and integrated into a planar resonator with a frequency of 6 GHz, which is weakly coupled with a pump line. Based on the experimental and model data, the presence of electrothermal feedback is shown, stability criteria are found, and I–V characteristics at microwaves are obtained. Bulk experimental samples with an absorber measuring 5 μm × 2.5 μm × 15 nm are fabricated with optical photolithography. At an amplifier channel noise of 3 K, the optical sensitivity of a prototype receiver can be expected at a level of 10 −15 W/Hz 1/2 .

Technical Physics•Jan 1, 2014•3 citations

Theoretical analysis of the new microwave detector based on a Josephson heterostructure

Igor A. Devyatov, M. Yu. Kupriyanov

We consider theoretically signal and noise properties of the new type of a high-sensitivity microwave detector, based on a SINIS (Superconductor-Insulator-Normal metal-Insulator-Superconductor) Josephson junction, in which the electron energy distribution function f(ε) in the nanoscale normal metal N region is nonequilibrium due to the capacitive coupling of this region with a receiving antenna. The deviation of f(ε) from the equilibrium leads to a change in the critical current Ic of the junction, i.e., in fact, to its inductance L = Φ0/2πIc (Φ0 ≈ 2.07*10-15 Wb is the magnetic flux quantum), which is the output signal of this device. Up to now there was no calculation of the noise properties of SINIS Josephson junction bolometer, taking into account non-equilibrium form of electron distribution function f(ε) in the normal metal absorber of this detector. We make this calculations and demonstrate, that noise parameter NEP of this detector is lower, than in others modern microwave detectors.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 23, 2009•0 citations
Nonequilibrium electron and phonon distribution functions have been calculated for a metallic absorber of a promising miniature superconducting detector irradiated by microwave radiation. The response of this detector has been calculated, and it has been shown that this detector can operate in either the photon counter mode or bolometric mode in dependence on the degree of nonequilibrium of the phonon subsystem.
This review presents the main characteristics and mechanisms of operation of superconductor–insulator–normal metal–insulator–superconductor (SINIS) microwave detectors. An analysis of the detectors’ performance against a quantum detector and a photon counter is given. Methods for cooling a superconductor using normal metal traps and the role of electron cooling in optimizing the current response to terahertz radiation are discussed. Fabrication methods using shadow evaporation as well as magnetron sputtering are described.
We study the proximity Josephson sensor in both bolometric and calorimetric operation and optimize it for different temperature ranges between 25 mK and a few kelvin. We investigate how the radiation power is absorbed in the sensor and find that the irradiated system is typically in a weak nonequilibrium state. We show in detail how the proximity of the superconductors affects the device response: for example, via changes in electron-phonon coupling and out-of-equilibrium noise. In addition, we estimate the applicability of graphene as the absorber material.
The results of pioneering experiments on using a new method of microwave recording the bolometric response from a metal film near its superconducting transition edge are analyzed. Experiments are carried out at 4.5 K using a thin-film niobium absorber with a critical temperature of 6.7 K. The validity of the adopted electrodynamic model is confirmed. The chip contains a miniature antenna tuned to approximately 600 GHz and integrated into a planar resonator with a frequency of 6 GHz, which is weakly coupled with a pump line. Based on the experimental and model data, the presence of electrothermal feedback is shown, stability criteria are found, and I–V characteristics at microwaves are obtained. Bulk experimental samples with an absorber measuring 5 μm × 2.5 μm × 15 nm are fabricated with optical photolithography. At an amplifier channel noise of 3 K, the optical sensitivity of a prototype receiver can be expected at a level of 10 −15 W/Hz 1/2 .
We consider theoretically signal and noise properties of the new type of a high-sensitivity microwave detector, based on a SINIS (Superconductor-Insulator-Normal metal-Insulator-Superconductor) Josephson junction, in which the electron energy distribution function f(ε) in the nanoscale normal metal N region is nonequilibrium due to the capacitive coupling of this region with a receiving antenna. The deviation of f(ε) from the equilibrium leads to a change in the critical current Ic of the junction, i.e., in fact, to its inductance L = Φ0/2πIc (Φ0 ≈ 2.07*10-15 Wb is the magnetic flux quantum), which is the output signal of this device. Up to now there was no calculation of the noise properties of SINIS Josephson junction bolometer, taking into account non-equilibrium form of electron distribution function f(ε) in the normal metal absorber of this detector. We make this calculations and demonstrate, that noise parameter NEP of this detector is lower, than in others modern microwave detectors.