Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica C Superconductivity

2.5 THz heterodyne receiver with NbN hot-electron-bolometer mixer

Alexei D. Semenov, Heinz‐Wilhelm Hübers, Heiko Richter, Manfred Birk, Michael Krocka, Ulrich Mair, Смирнов Константин Владимирович, Gregory N Gol'tsman, Boris M. Voronov

Published Aug 1, 2002• 17 citations
Publisher
DOI
10.1016/s0921-4534(02)00720-7

Related papers

Sensitivity of an NbN hot electron bolometer based heterodyne receiver at 4.3 THz

P. Khosropanah, W. M. Laauwen, J. R. Gao +3 more

•Jan 1, 2007•0 citations

THz superconducting hot electron bolometer heterodyne receivers

J. R. Gao, Merlijn Hajenius, Z.Q. Yang +5 more

We will highlight recent progress in superconducting NbN hot electron bolometer (HEB) mixers achieved through close collaboration between SRON and TU Delft.

International Conference on Infrared, Millimeter, and Terahertz Waves (IRMMW-THz)•Sep 1, 2006•1 citation

Noise performance of quasioptical ultrathin NbN hot-electron bolometer mixer at 2.5 and 3.8 THz

Sergey V. Antipov, Yu.B. Vachtornin, S. N. Maslennikov +5 more

To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.

International Kharkiv Symposium on Physics and Engineering of Microwaves, Millimeter and Submillimeter Waves•Oct 26, 2004•0 citations

Terahertz heterodyne receivers based on superconductive hot-electron bolometer mixers

Matvey I. Finkel, S. N. Maslennikov, Gregory N Gol'tsman

Radiophysics and Quantum Electronics•Oct 1, 2005•2 citations

Terahertz Superconducting Hot Electron Bolometer Heterodyne Receivers

J. R. Gao, Merlijn Hajenius, Zhenyu Yang +4 more

We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•28 citations

3.1-THz Heterodyne Receiver Using an NbTiN Hot-Electron Bolometer Mixer and a Quantum Cascade Laser

Shoichi Shiba, Yoshihisa Irimajiri, T. Yamakura +4 more

We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.

IEEE Transactions on Terahertz Science and Technology•Dec 6, 2011•18 citations
To put space-based and airborne heterodyne instruments into operation at frequencies above 1 THz the superconducting NbN hot-electron bolometer (HEB) will be incorporated into heterodyne receiver as a mixer. At frequencies above 1.3 THz the sensitivity of the NbN HEB mixers outperform the one of the Schottky diodes and SIS-mixers, and the receiver noise temperature of the NbN HEB mixers increase with frequency. In this paper we present the results of the noise temperature measurements within one batch of NbN HEB mixers based on 3.5 mn thick superconducting NbN film grown on Si substrate with MgO buffer layer at the LO frequencies 2.5 THz and 3.8 THz.
We highlight the progress on NbN hot electron bolometer (HEB) mixers achieved through fruitful collaboration between SRON Netherlands Institute for Space Research and Delft University of Technology, the Netherlands. This includes the best receiver noise temperatures of 700 K at 1.63 THz using a twin-slot antenna mixer and 1050 K at 2.84 THz using a spiral antenna coupled HEB mixer. The mixers are based on thin NbN films on Si and fabricated with a new contact-process and-structure. By reducing their areas HEB mixers have shown an LO power requirement as low as 30 nW. Those small HEB mixers have demonstrated equivalent sensitivity as those with large areas provided the direct detection effect due to broadband radiation is removed. To manifest that a HEB based heterodyne receiver can in practice be used at arbitrary frequencies above 2 THz, we demonstrate a 2.8 THz receiver using a THz quantum cascade laser (QCL) as local oscillator.
We have developed the 3.1-THz heterodyne receiver using an NbTiN Hot-Electron Bolometer (HEB) mixer and a THz Quantum Cascade Laser (THz-QCL) as a local oscillator. A quasi optical twin-slot antenna is adopted for the coupling of the RF signal with the mixer. The receiver noise temperature is measured to be 5600 K in DSB. When the optical loss is corrected, it is as low as 2100 K. This result demonstrates that the NbTiN HEB mixer works with the equivalent level of performance at 3.1 THz in comparison with the NbN HEB mixers usually employed in this frequency region.