Journal of Low Temperature Physics

A High-Sensitivity Microwave-Single-Photon Detector with Rydberg Atoms at Low Temperature

T. Haseyama, T. Arai, A. Fukuda, H. Funahashi, S. Ikeda, K. Imai, Yasuhito Isozumi, Takashi Kato, Yoshiaki Kido, Atsushi Matsubara, S. Matsuki, T. Mizusaki, Tomoaki Nishimura, D. Ohsawa, A. Sawada, Yoshiro Takahashi, M. Tosaki, Kazuhiro Yamamoto

Published Nov 27, 2007• 4 citations
Publisher
DOI
10.1007/s10909-007-9586-4

Related papers

Single-photon detection of microwave blackbody radiations in a low-temperature resonant-cavity with high Rydberg atoms

M. Tada, Yasuaki Kishimoto, K. Kominato +7 more

Physics Letters A•Oct 5, 2005•25 citations

Microwave Single-Photon Detection with Rydberg Atoms at Low Temperature

Masahiro Shibata

•Mar 23, 2004•0 citations

Microwave single-photon detection with Rydberg atoms at low temperature

政宏 柴田

•Jan 1, 2004•0 citations

Simulation of Highly Sensitive, Room-Temperature Terahertz Quantum Detector Based on Rb Rydberg Atoms

Lei Hou, Qihui He, Junnan Wang +4 more

•Jan 1, 2024•0 citations

Boosting Axion Searches with Quantum Sensing

Claudio D. Gatti

The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.

IEEE Workshop on Low Temperature Electronics (WOLTE)•Apr 12, 2021•1 citation

Continuous wideband microwave-to-optical converter based on room-temperature Rydberg atoms

Sebastian Borówka, Uliana Pylypenko, Mateusz Mazelanik +1 more

Abstract The coupling of microwave and optical systems presents an immense challenge due to the natural incompatibility of energies, but potential applications range from optical interconnects for quantum computers to next-generation quantum microwave sensors, detectors and coherent imagers. Several of the engineered platforms that have emerged are constrained by specific conditions, such as cryogenic environments, impulse protocols or narrowband fields. Here we employ Rydberg atoms that allow the wideband coupling of optical and microwave photons at room temperature with the use of a modest set-up. We present continuous-wave conversion of a 13.9 GHz field to a near-infrared optical signal using an ensemble of Rydberg atoms via a free-space six-wave mixing process designed to minimize noise interference from any nearby frequencies. The Rydberg photonic converter exhibits a conversion dynamic range of 57 dB and a wide conversion bandwidth of 16 MHz. Using photon counting, we demonstrate the readout of photons of free-space 300 K thermal background radiation at 1.59 nV cm −1 rad −1/2 s −1/2 (3.98 nV cm −1 Hz −1/2 ) with a sensitivity down to 3.8 K of noise-equivalent temperature, allowing us to observe Hanbury Brown and Twiss interference of microwave photons.

arXiv:2302.08380•Nature Photonics•Oct 5, 2023•110 citations
The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.
Abstract The coupling of microwave and optical systems presents an immense challenge due to the natural incompatibility of energies, but potential applications range from optical interconnects for quantum computers to next-generation quantum microwave sensors, detectors and coherent imagers. Several of the engineered platforms that have emerged are constrained by specific conditions, such as cryogenic environments, impulse protocols or narrowband fields. Here we employ Rydberg atoms that allow the wideband coupling of optical and microwave photons at room temperature with the use of a modest set-up. We present continuous-wave conversion of a 13.9 GHz field to a near-infrared optical signal using an ensemble of Rydberg atoms via a free-space six-wave mixing process designed to minimize noise interference from any nearby frequencies. The Rydberg photonic converter exhibits a conversion dynamic range of 57 dB and a wide conversion bandwidth of 16 MHz. Using photon counting, we demonstrate the readout of photons of free-space 300 K thermal background radiation at 1.59 nV cm −1 rad −1/2 s −1/2 (3.98 nV cm −1 Hz −1/2 ) with a sensitivity down to 3.8 K of noise-equivalent temperature, allowing us to observe Hanbury Brown and Twiss interference of microwave photons.