Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Progress report of an 27Al+ ion optical clock

Ke Deng, Zhilin Xu, W. H. Yuan, C. B. Qin, A. Deng, Yuling Sun, Jianbing Zhang, Z. H. Lu, J. Luo

Published Jul 1, 2013• 0 citations
Publisher

Abstract

An Al+ion optical clock is under development at Huazhong University of Science and Technology in China. We have successfully crystallized Magnesium ions. Through micromotion compensation and trapping parameters optimization, temperature of a trapped single ion is lowered to be around 19 mK.
DOI
10.1109/eftf-ifc.2013.6702143

Related papers

Recent progress on the27Al+ion optical clock

Zhilin Xu, W. H. Yuan, Xiangbin Zeng +5 more

An aluminium ion optical clock is under development at Huazhong University of Science and Technology. The 25 Mg + ion is chosen as logic ion to sympathetically cool an Al + ion and to detect its states. The 25 Mg + ion is cooled to the motional ground state through Raman sideband cooling as the first step for quantum logic spectroscopy. Ultra-stable lasers for the interrogation of the clock transition are developed. The instability of the laser beat frequency is 1.2 x 10 -15 at 1 s, which is close to the thermal noise limit of the reference cavity.

Journal of Physics Conference Series•Jun 1, 2016•8 citations

Towards an 27Al+ ions optical clock

Zetian Xu, Xiaoyi Zeng, Xiaohui Shi +4 more

Magnesium ion which acts as the logic ion in27Al+ion optical clock is trapped and laser cooled in a linear ion trap. Rabi oscillation between two hyperfine ground states of25Mg+ion is observed and resonant frequency between two hyperfine ground states of25Mg+ion is measured. Earth magnetic field is compensated with three pairs of mutually perpendicular Helmholtz coils. Light shift induced by the Raman cooling beams is measured. With the photo-ionization laser of Al, Al+ion is trapped together with Mg+ion. The linewidth of the clock laser of the27Al+ion is measured to be about 0.8 Hz. The Allan deviation of the beat note from two independent lasers is 6.5×10-15at 1s.

European Frequency and Time Forum•Jun 1, 2014•0 citations

Towards a transportable aluminium ion quantum logic optical clock

S. Hannig, L. Pelzer, N. Scharnhorst +7 more

With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.

arXiv:1901.02250•Review of Scientific Instruments•May 1, 2019•70 citations

Towards an 27Al+ based optical clock

Ksenia Yu. Khabarova, Ilia V. Zalivako, Ilya A. Semerikov +2 more

We present current status of a project aimed for development of an optical clock based on27Al+ ion and auxiliary25Mg+ ion started at LPI. Results on Mg+ ions trapping and cooling are presented as well as a clock laser design.

European Frequency and Time Forum•Apr 1, 2018•3 citations

Research progress of Al$^{+}$ ion optical frequency standard based on quantum logic technique

Kui Liu, Xiaohui Shi, Ke Deng +4 more

Optical atomic clocks have many applications in the definition of the time and the length, measurement of fundamental constants and their potential variations with time, testing of relativity, very long baseline interferometry, geodesy, and global navigation satellite systems. An optical clock consists of three parts: ultra-stable laser, frequency comb and trapped ions or atoms. The accuracy of optical atomic clocks can be affected by Doppler shift, Zeeman shift, Stark shift, collision shift, blackbody radiation (BBR) shift, etc. The BBR shift is very difficult to be characterized and controlled. Among all optical atomic clocks under current development, Al$^+$ optical clock has the smallest BBR shift at a level of $4.0\times10^{-19}$, therefore the Al$^+$ is a promising ion for high-accuracy optical frequency standard. In this article we give a review on the three parts of optical frequency standards, the basic working principle of Al$^+$ ion optical frequency standard based on quantum logic technique, and research progress of an Al$^+$ optical clock under development at Huazhong University of Science and Technology.

Zhongguo kexue. Wulixue Lixue Tianwenxue•Jun 13, 2016•0 citations

Single-ion, transportable optical atomic clocks

Marion Delehaye, Clément Lacroûte

For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.

arXiv:1804.02168•Journal of Modern Optics•Mar 7, 2018•47 citations
An aluminium ion optical clock is under development at Huazhong University of Science and Technology. The 25 Mg + ion is chosen as logic ion to sympathetically cool an Al + ion and to detect its states. The 25 Mg + ion is cooled to the motional ground state through Raman sideband cooling as the first step for quantum logic spectroscopy. Ultra-stable lasers for the interrogation of the clock transition are developed. The instability of the laser beat frequency is 1.2 x 10 -15 at 1 s, which is close to the thermal noise limit of the reference cavity.
Magnesium ion which acts as the logic ion in27Al+ion optical clock is trapped and laser cooled in a linear ion trap. Rabi oscillation between two hyperfine ground states of25Mg+ion is observed and resonant frequency between two hyperfine ground states of25Mg+ion is measured. Earth magnetic field is compensated with three pairs of mutually perpendicular Helmholtz coils. Light shift induced by the Raman cooling beams is measured. With the photo-ionization laser of Al, Al+ion is trapped together with Mg+ion. The linewidth of the clock laser of the27Al+ion is measured to be about 0.8 Hz. The Allan deviation of the beat note from two independent lasers is 6.5×10-15at 1s.
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10−17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=−0.4−0.3+0.4×10−18 and the black-body radiation shift is δνBBR/ν = (−4.0 ± 0.4) × 10−18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.
Research progress of Al+^{+}+ ion optical frequency standard based on quantum logic technique
Optical atomic clocks have many applications in the definition of the time and the length, measurement of fundamental constants and their potential variations with time, testing of relativity, very long baseline interferometry, geodesy, and global navigation satellite systems. An optical clock consists of three parts: ultra-stable laser, frequency comb and trapped ions or atoms. The accuracy of optical atomic clocks can be affected by Doppler shift, Zeeman shift, Stark shift, collision shift, blackbody radiation (BBR) shift, etc. The BBR shift is very difficult to be characterized and controlled. Among all optical atomic clocks under current development, Al+^++ optical clock has the smallest BBR shift at a level of 4.0×10−194.0\times10^{-19}4.0×10−19, therefore the Al+^++ is a promising ion for high-accuracy optical frequency standard. In this article we give a review on the three parts of optical frequency standards, the basic working principle of Al+^++ ion optical frequency standard based on quantum logic technique, and research progress of an Al+^++ optical clock under development at Huazhong University of Science and Technology.
For the past 15 years, tremendous progress within the fields of laser stabilization, optical frequency combs and atom cooling and trapping have allowed the realization of optical atomic clocks with unrivaled performances. These instruments can perform frequency comparisons with fractional uncertainties well below 10-17, finding applications in fundamental physics tests, relativistic geodesy and time and frequency metrology. Even though most optical clocks are currently laboratory setups, several proposals for using these clocks for field measurements or within an optical clock network have been published, and most of time and frequency metrology institutes have started to develop transportable optical clocks. For the purpose of this special issue, we chose to focus on trapped-ion optical clocks. Even though their short-term fractional frequency stability is impaired by a lower signal-to-noise ratio, they offer a high potential for compactness: trapped ions demand low optical powers and simple loading schemes, and can be trapped in small vacuum chambers. We review recent advances on the clock key components, including ion trap and ultra-stable optical cavity, as well as existing projects and experiments which draw the picture of what future transportable, single-ion optical clocks may resemble.