Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Luminescence

Effects of saturation on the elimination of inhomogeneous broadening by nondegenerate fully resonant four-wave mixing

Roger J. Carlson, John Curtis Wright

Published Dec 1, 1987• 4 citations
Publisher
DOI
10.1016/0022-2313(87)90144-x

Related papers

Saturation effects and inhomogeneous broadening in Doppler-free degenerate four-wave mixing

Duncan G. Steel, Jenny Lam

Optics Communications•Dec 1, 1981•25 citations

Collision induced and resonantly enhanced extra resonances in four-wave mixing in inhomogeneously broadened four level systems

Suneel Pratap Singh, Geetha Govind

Optics Communications•Jan 29, 2008•0 citations

Nondegenerate four-wave mixing in a homogeneously broadened two-level system with saturating pump waves

Joseph Nilsen, Avigail Yariv

The formulation of phase conjugation via nondegenerate four-wave mixing in a homogeneously broadened resonant medium is generalized to include saturating pump waves. An ultrahigh-Qoptical filter is predicted, showing both gain and a bandwidth less than the homogeneous linewidth of the atom. The dependence of the filter function on the ac Stark effect and on the use of asymmetric pump wave intensities is discussed. In addition, several new phenomena are shown which manifest themselves as a dip in the degenerate reflectivity at line center.

IEEE Journal of Quantum Electronics•Nov 1, 1982•16 citations

High-pump-power effects on resonant nearly degenerate four-wave-mixing signal for homogeneously and inhomogeneously broadened two-level systems

L. Márquez, Isaac Reif, Héctor J. Franco +2 more

The influence of the high-pump-field intensity saturation and dynamic Stark effects on the resonant nearly degenerate four-wave-mixing signal (${\mathrm{\ensuremath{\omega}}}_{3}$=2${\mathrm{\ensuremath{\omega}}}_{1}$-${\mathrm{\ensuremath{\omega}}}_{2}$) is studied in a frequency space defined by the pump- and probe-field frequencies, ${\mathrm{\ensuremath{\omega}}}_{1}$ and ${\mathrm{\ensuremath{\omega}}}_{2}$, respectively. Variable inhomogeneous widths have been considered ranging from extremely narrow (homogeneous distribution) to extremely wide. Remarkable differences between nearly homogeneously broadened systems and extreme inhomogeneous ones are exhibited. It is shown, for the situation of homogeneous broadening, that the spectra carried on with fixed probe and fixed pump frequency values have substantial differences in shape. These differences disappear in the situation of extreme inhomogeneous broadening. Fixed-pump-frequency resonant and fixed-probe-frequency nonresonant spectra are proposed as very convenient tools to yield useful evidence about the width of the inhomogeneous molecular distribution.

Physical Review A•May 1, 1993•20 citations

Saturation effect in nondegenerate two-wave mixing

Haitian Zhou, Xin Mi, Qian Jiang +2 more

Optics Communications•Sep 1, 1990•10 citations

Saturation of resonant wave mixing in excited four-level media

A. G. Spiro

Optics and Spectroscopy•Jul 1, 1998•0 citations
The formulation of phase conjugation via nondegenerate four-wave mixing in a homogeneously broadened resonant medium is generalized to include saturating pump waves. An ultrahigh-Qoptical filter is predicted, showing both gain and a bandwidth less than the homogeneous linewidth of the atom. The dependence of the filter function on the ac Stark effect and on the use of asymmetric pump wave intensities is discussed. In addition, several new phenomena are shown which manifest themselves as a dip in the degenerate reflectivity at line center.
The influence of the high-pump-field intensity saturation and dynamic Stark effects on the resonant nearly degenerate four-wave-mixing signal (${\mathrm{\ensuremath{\omega}}}_{3}$=2${\mathrm{\ensuremath{\omega}}}_{1}$-${\mathrm{\ensuremath{\omega}}}_{2}$) is studied in a frequency space defined by the pump- and probe-field frequencies, ${\mathrm{\ensuremath{\omega}}}_{1}$ and ${\mathrm{\ensuremath{\omega}}}_{2}$, respectively. Variable inhomogeneous widths have been considered ranging from extremely narrow (homogeneous distribution) to extremely wide. Remarkable differences between nearly homogeneously broadened systems and extreme inhomogeneous ones are exhibited. It is shown, for the situation of homogeneous broadening, that the spectra carried on with fixed probe and fixed pump frequency values have substantial differences in shape. These differences disappear in the situation of extreme inhomogeneous broadening. Fixed-pump-frequency resonant and fixed-probe-frequency nonresonant spectra are proposed as very convenient tools to yield useful evidence about the width of the inhomogeneous molecular distribution.