Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Using frequency-narrowed, tunable laser diode arrays with integrated volume holographic gratings for spin-exchange optical pumping at high resonant fluxes and xenon densities

N. Whiting, Panayiotis Nikolaou, Neil A. Eschmann, Michael J. Barlow, Robert M. Lammert, J. E. Ungar, Wentao Hu, Laurent Vaissié, Boyd M. Goodson

Published Mar 1, 2012• 42 citations
Publisher
DOI
10.1007/s00340-012-4924-x

Related papers

Spin-Exchange Optical Pumping Using Frequency-Narrowed Tunable High Power Laser Diodes

Ian A. Nelson, Bien Chann, Thad G Walker

APS•Jun 1, 2000•0 citations

Xe 129 -Cs ( D 1 , D 2 ) versus Xe 129 -Rb ( D 1 ) spin-exchange optical pumping at high xenon densities using high-power laser diode arrays

Nicholas Whiting, Neil A. Eschmann, Boyd M. Goodson +1 more

We investigate $^{129}\mathrm{Xe}$-Cs (${D}_{1},{D}_{2}$) spin exchange optical pumping (SEOP) at high Xe densities ($~$0.12--2.44 amagat) using newly available high-power ($>$40 W) laser diode arrays and compare with $^{129}\mathrm{Xe}$-Rb ${D}_{1}$ SEOP under similar conditions. At elevated Xe densities, the spin-exchange rate (per alkali-metal atom, ${\ensuremath{\gamma}}^{\ensuremath{'}}$) for Cs-$^{129}\mathrm{Xe}$ is $~$1.5-fold greater than that for Rb-$^{129}\mathrm{Xe}$. Higher spin-exchange rates and lower $^{129}\mathrm{Xe}$ spin-destruction rates for Cs-$^{129}\mathrm{Xe}$ versus Rb-$^{129}\mathrm{Xe}$ contribute to $~$twofold improvement in $^{129}\mathrm{Xe}$ nuclear spin polarization measured at 9.4 T---with the largest gains observed at the highest Xe densities.

Physical Review A•May 26, 2011•23 citations

Hyperpolarised helium and xenon production and applications to imaging and materials analysis

Cavin Talbot

In this thesis I discuss experiments to create hyperpolarised noble gases. In particular, we have constructed an apparatus to hyperpolarise helium and xenon gases and used these resources to image the lungs of living rats and probe the physical properties of mesoporous solids. The apparatus uses a line-width narrowed laser diode array to optically pump rubidium vapour which then polarises the noble gases through spin-exchange collisions. We have also developed techniques to optimise both the amount and rate of polarisation. Using these techniques, we have shown that the apparatus can produce hyperpolarised helium in 350mL volumes with a polarisation of up to 25%. It can also produce hyperpolarised xenon in a continuous flow which results in 10% polarisation of the xenon at a rate of 1018 polarised atoms per minute with only four watts of laser light incident on the cell. The optical feedback system for laser diode arrays was improved to correct for the divergence of the beam caused by curvature in the array of diode elements. This curvature of the array is an artifact of the manufacturing process and causes an increase in the full width half maximum (FWHM) achievable for the spectral profile of the array when using optical feedback to spectrally narrow the laser diode array. The optical feedback allowed the tenfold narrowing of the laser line-width with the additional treatment of the “smile” giving a further 30% improvement. The feedback allowed more efficient absorption of the light at much lower pressures. A probe was designed and constructed to measure the polarisation of the rubidium atoms in the two possible levels of the 5S ground state. This probe enabled the rapid optimisation of the polarisation of the rubidium atoms which in turn led to the best polarisation rates measured for the equipment. We have successfully used the hyperpolarised helium from our apparatus to produce high resolution images of lungs of rats that have been kept alive for the duration of the experiments on a ventilator system. These images far surpass the quality of lung images from standard MRI techniques. We also used the hyperpolarised xenon gas to measure pore sizes in mesoporous solids by detecting the shift in the xenon resonance frequency caused by the interaction with the material, and we investigated the effect on the frequency shift of water absorbed in the material. The pore sizes of the materials ranged from 2.5 to 16 nm.

•Aug 1, 2008•0 citations

Dual-frequency optical pumping for spin-polarizing a lithium atomic beam

G. Baum, C. Denise Caldwell, W. Schröder

Applied Physics A•Feb 1, 1980•31 citations

Physics of practical spin-exchange optical pumping

Ian A. Nelson

•Oct 1, 2001•12 citations

Optical pumping of high-density Rb with a broadband dye laser and GaAlAs diode laser arrays: Application to He3 polarization

Mark E. Wagshul, T. E. Chupp

We have studied laser optical pumping of Rb at densities up to 4\ifmmode\times\else\texttimes\fi{}${10}^{14}$ atoms/${\mathrm{cm}}^{3}$ and produced polarized $^{3}\mathrm{He}$ by spin exchange with Rb. Numerical calculations show that for a high-density Rb vapor GaAlAs diode laser arrays can provide results similar to those obtained with a broadband ${\mathrm{Kr}}^{+}$-ion--dye-laser system. We have confirmed these calculations with measurements using a 40-GHz full width at half maximum bandwidth dye laser and 100- and 500-mW GaAlAs diode laser arrays (Spectra Diode Labs Array Nos. SDL-2410C and SDL-2450C). We have optically pumped Rb of density [Rb]=4\ifmmode\times\else\texttimes\fi{}${10}^{14}$ atoms/${\mathrm{cm}}^{3}$, and we have measured up to 70% $^{3}\mathrm{He}$ polarization in a 4-${\mathrm{cm}}^{3}$ volume with 600 mW from the dye laser. With the diode laser arrays, we have pumped with 30 and 300 mW with results comparable to those obtained with the dye laser. With a 1-W diode laser array, we anticipate 70--80 % $^{3}\mathrm{He}$ polarization in a 4-${\mathrm{cm}}^{3}$ volume.

Physical Review A•Oct 1, 1989•70 citations
We investigate 129Xe^{129}\mathrm{Xe}129Xe-Cs (D1,D2{D}_{1},{D}_{2}D1​,D2​) spin exchange optical pumping (SEOP) at high Xe densities ($~0.12−−2.44amagat)usingnewlyavailablehigh−power(0.12--2.44 amagat) using newly available high-power (0.12−−2.44amagat)usingnewlyavailablehigh−power(>$40 W) laser diode arrays and compare with 129Xe^{129}\mathrm{Xe}129Xe-Rb D1{D}_{1}D1​ SEOP under similar conditions. At elevated Xe densities, the spin-exchange rate (per alkali-metal atom, ${\ensuremath{\gamma}}^{\ensuremath{'}}$) for Cs-129Xe^{129}\mathrm{Xe}129Xe is $~1.5−foldgreaterthanthatforRb−1.5-fold greater than that for Rb-1.5−foldgreaterthanthatforRb−^{129}\mathrm{Xe}$. Higher spin-exchange rates and lower 129Xe^{129}\mathrm{Xe}129Xe spin-destruction rates for Cs-129Xe^{129}\mathrm{Xe}129Xe versus Rb-129Xe^{129}\mathrm{Xe}129Xe contribute to  ~ twofold improvement in 129Xe^{129}\mathrm{Xe}129Xe nuclear spin polarization measured at 9.4 T---with the largest gains observed at the highest Xe densities.
In this thesis I discuss experiments to create hyperpolarised noble gases. In particular, we have constructed an apparatus to hyperpolarise helium and xenon gases and used these resources to image the lungs of living rats and probe the physical properties of mesoporous solids. The apparatus uses a line-width narrowed laser diode array to optically pump rubidium vapour which then polarises the noble gases through spin-exchange collisions. We have also developed techniques to optimise both the amount and rate of polarisation. Using these techniques, we have shown that the apparatus can produce hyperpolarised helium in 350mL volumes with a polarisation of up to 25%. It can also produce hyperpolarised xenon in a continuous flow which results in 10% polarisation of the xenon at a rate of 1018 polarised atoms per minute with only four watts of laser light incident on the cell. The optical feedback system for laser diode arrays was improved to correct for the divergence of the beam caused by curvature in the array of diode elements. This curvature of the array is an artifact of the manufacturing process and causes an increase in the full width half maximum (FWHM) achievable for the spectral profile of the array when using optical feedback to spectrally narrow the laser diode array. The optical feedback allowed the tenfold narrowing of the laser line-width with the additional treatment of the “smile” giving a further 30% improvement. The feedback allowed more efficient absorption of the light at much lower pressures. A probe was designed and constructed to measure the polarisation of the rubidium atoms in the two possible levels of the 5S ground state. This probe enabled the rapid optimisation of the polarisation of the rubidium atoms which in turn led to the best polarisation rates measured for the equipment. We have successfully used the hyperpolarised helium from our apparatus to produce high resolution images of lungs of rats that have been kept alive for the duration of the experiments on a ventilator system. These images far surpass the quality of lung images from standard MRI techniques. We also used the hyperpolarised xenon gas to measure pore sizes in mesoporous solids by detecting the shift in the xenon resonance frequency caused by the interaction with the material, and we investigated the effect on the frequency shift of water absorbed in the material. The pore sizes of the materials ranged from 2.5 to 16 nm.
We have studied laser optical pumping of Rb at densities up to 4\ifmmode\times\else\texttimes\fi{}1014{10}^{14}1014 atoms/cm3{\mathrm{cm}}^{3}cm3 and produced polarized 3He^{3}\mathrm{He}3He by spin exchange with Rb. Numerical calculations show that for a high-density Rb vapor GaAlAs diode laser arrays can provide results similar to those obtained with a broadband Kr+{\mathrm{Kr}}^{+}Kr+-ion--dye-laser system. We have confirmed these calculations with measurements using a 40-GHz full width at half maximum bandwidth dye laser and 100- and 500-mW GaAlAs diode laser arrays (Spectra Diode Labs Array Nos. SDL-2410C and SDL-2450C). We have optically pumped Rb of density [Rb]=4\ifmmode\times\else\texttimes\fi{}1014{10}^{14}1014 atoms/cm3{\mathrm{cm}}^{3}cm3, and we have measured up to 70% 3He^{3}\mathrm{He}3He polarization in a 4-cm3{\mathrm{cm}}^{3}cm3 volume with 600 mW from the dye laser. With the diode laser arrays, we have pumped with 30 and 300 mW with results comparable to those obtained with the dye laser. With a 1-W diode laser array, we anticipate 70--80 % 3He^{3}\mathrm{He}3He polarization in a 4-cm3{\mathrm{cm}}^{3}cm3 volume.