Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

High-resolution ghost image and ghost diffraction experiments with incoherent pseudo-thermal light

A. Gatti, Davide Magatti, Morten Bache, E. Brambilla, F. Ferri, Luigi A. Lugiato

Published Aug 18, 2005• 3 citations
Publisher

Abstract

High-resolution ghost image and ghost diffraction are performed by using a single source of pseudo-thermal speckle light divided by a beam splitter. By only operating on the optical setup of the light in the reference arm, that never interacted with the object, we are able to pass from the image to the diffraction pattern. The product of spatial resolutions of the ghost image and ghost diffraction experiments is shown to overcome a limit which was formerly thought to be achievable only with entangled photons. A complementarity between the spatial coherence of the beams and their mutual correlation is demonstrated by showing a complementarity between ghost diffraction and ordinary diffraction patterns.

DOI
10.1117/12.614808

Related papers

High-Resolution Ghost Image and Ghost Diffraction Experiments with Thermal Light

F. Ferri, Davide Magatti, A. Gatti +3 more

High-resolution ghost image and ghost diffraction experiments are performed by using a single classical source of pseudothermal speckle light divided by a beam splitter. Passing from the image to the diffraction result solely relies on changing the optical setup in the reference arm, while leaving the object arm untouched. The product of spatial resolutions of the ghost image and ghost diffraction experiments is shown to overcome a limit which seemed to be achievable only with entangled photons.

arXiv:quant-ph/0408021•Physical Review Letters•May 12, 2005•780 citations

Ghost imaging with zero photons

Meixue Chen, Yiqi Song, Yu Gu +8 more

Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.

quant-pharXiv:2604.07782•Physical Review A•Apr 10, 2026•1 citation

Third-order optical intensity correlation measurements of pseudo-thermal light

Xi-Hao Chen, Wei Tao Wu, Shao-Ying Meng +1 more

Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in N th-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the N th-order interference pattern or ghost image in the thermal N th-order interference or ghost imaging.

Chinese Physics B•Sep 1, 2014•2 citations

Quantum and Classical Coincidence Imaging

Ryan S. Bennink, Sean J. Bentley, Robert W. Boyd +1 more

Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.

Physical Review Letters•Jan 22, 2004•418 citations

Experimental Limits of Ghost Diffraction: Popper’s Thought Experiment

Paul‐Antoine Moreau, Peter A. Morris, Ermes Toninelli +5 more

Quantum ghost diffraction harnesses quantum correlations to record diffraction or interference features using photons that have never interacted with the diffractive element. By designing an optical system in which the diffraction pattern can be produced by double slits of variable width either through a conventional diffraction scheme or a ghost diffraction scheme, we can explore the transition between the case where ghost diffraction behaves as conventional diffraction and the case where it does not. For conventional diffraction the angular extent increases as the scale of the diffracting object is reduced. By contrast, we show that no matter how small the scale of the diffracting object, the angular extent of the ghost diffraction is limited (by the transverse extent of the spatial correlations between beams). Our study is an experimental realisation of Popper's thought experiment on the validity of the Copenhagen interpretation of quantum mechanics. We discuss the implication of our results in this context and explain that it is compatible with, but not proof of, the Copenhagen interpretation.

Scientific Reports•Aug 29, 2018•16 citations

Super-resolution imaging by anticorrelation of optical intensities

Shao-Ying Meng, Ying-Hui Sha, Qiang Fu +5 more

Photon bunching, a feature of classical thermal fields, has been widely exploited to implement ghost imaging. Here we show that spatial photon antibunching can be experimentally observed via low-pass filtering of the intensities of the two thermal light beams from a beamsplitter correlation system. Through suitable choice of the filter thresholds, the minimum of the measured normalized anti-correlation function, i.e., antibunching dip, can be lower than 0.2, while its full-width-at-half-maximum can be much narrower than that of the corresponding positive correlation peak. Based on this anti-correlation effect, a super-resolution negative ghost image is achieved in a lensless scheme, in which the spatial resolution can exceed the Rayleigh diffraction limit by more than a factor of two. The setup is quite simple and easy to implement, which is an advantage for practical applications.

Optics Letters•Sep 24, 2018•13 citations
High-resolution ghost image and ghost diffraction are performed by using a single source of pseudo-thermal speckle light divided by a beam splitter. By only operating on the optical setup of the light in the reference arm, that never interacted with the object, we are able to pass from the image to the diffraction pattern. The product of spatial resolutions of the ghost image and ghost diffraction experiments is shown to overcome a limit which was formerly thought to be achievable only with entangled photons. A complementarity between the spatial coherence of the beams and their mutual correlation is demonstrated by showing a complementarity between ghost diffraction and ordinary diffraction patterns.
Ghost imaging was first demonstrated with entangled photon pairs and well-known for its peculiar properties. The signal beam that illuminates the object possesses no spatial resolution, whereas the reference beam, which never interacts with the object, is spatially resolved. Either beam alone cannot retrieve the image, which can only be obtained when the signal and reference beams are correlated. Here we will report a ghost imaging experiment with even more peculiar properties, in which the image can be reconstructed when no photon interacts with the object or even no photon in neither signal nor reference beam. All the photons interacted with the object are discarded. Only the time bins with zero photon are employed to retrieve the image, a process referred to as "ghost imaging with zero photons" hereafter. The reason why ghost image can be retrieved with zero photons is jointly determined by photon-number projection measurement and photon statistics of thermal light. The results are helpful to resolve the debate on the physics of ghost imaging and understand the relation between quantum and classical correlations.
Third-order Hanbrury Brown—Twiss and double-slit interference experiments with a pseudo-thermal light are performed by recording intensities in single, double and triple optical paths, respectively. The experimental results verifies the theoretical prediction that the indispensable condition for achieving a interference pattern or ghost image in N th-order intensity correlation measurements is the synchronous detection of the same light field by each reference detector, no matter the intensities recorded in one, or two, or N optical paths. It is shown that, when the reference detectors are scanned in the opposite directions, the visibility and resolution of the third-order spatial correlation function of thermal light is much better than that scanned in the same direction, but it is no use for obtaining the N th-order interference pattern or ghost image in the thermal N th-order interference or ghost imaging.
Coincidence, or ghost, imaging is a technique that uses two correlated optical fields to form an image of an object. In this work we identify aspects of coincidence imaging which can be performed with classically correlated light sources and aspects which require quantum entanglement. We find that entangled photons allow high-contrast, high-resolution imaging to be performed at any distance from the light source. We demonstrate this fact by forming ghost images in the near and far fields of an entangled photon source, noting that the product of the resolutions of these images is a factor of 3 better than that which is allowed by classical diffraction theory.
Quantum ghost diffraction harnesses quantum correlations to record diffraction or interference features using photons that have never interacted with the diffractive element. By designing an optical system in which the diffraction pattern can be produced by double slits of variable width either through a conventional diffraction scheme or a ghost diffraction scheme, we can explore the transition between the case where ghost diffraction behaves as conventional diffraction and the case where it does not. For conventional diffraction the angular extent increases as the scale of the diffracting object is reduced. By contrast, we show that no matter how small the scale of the diffracting object, the angular extent of the ghost diffraction is limited (by the transverse extent of the spatial correlations between beams). Our study is an experimental realisation of Popper's thought experiment on the validity of the Copenhagen interpretation of quantum mechanics. We discuss the implication of our results in this context and explain that it is compatible with, but not proof of, the Copenhagen interpretation.
Photon bunching, a feature of classical thermal fields, has been widely exploited to implement ghost imaging. Here we show that spatial photon antibunching can be experimentally observed via low-pass filtering of the intensities of the two thermal light beams from a beamsplitter correlation system. Through suitable choice of the filter thresholds, the minimum of the measured normalized anti-correlation function, i.e., antibunching dip, can be lower than 0.2, while its full-width-at-half-maximum can be much narrower than that of the corresponding positive correlation peak. Based on this anti-correlation effect, a super-resolution negative ghost image is achieved in a lensless scheme, in which the spatial resolution can exceed the Rayleigh diffraction limit by more than a factor of two. The setup is quite simple and easy to implement, which is an advantage for practical applications.