Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Procedia

Improved Characteristics of Integrated HTS rf SQUID on Bicrystal SrTiO3 Substrate Resonator Covered with HTS Thin Films in Flip-Chip Geometry

Yoshimi Hatsukade, Makoto TAKEMOTO, Ryuichi Kurosawa, Yousuke Uchida, Saburo Tanaka

Published Jan 1, 2012• 0 citations
Publisher

Abstract

Integrated high-temperature superconductor (HTS) radio-frequency (rf) superconducting quantum interference devices (SQUIDs) based on a bicrystal SrTiO3 substrate was investigated for application to magnetic contaminant detection. By covering a wide superconducting weak link and/or a slit of the YBa2Cu3O7-x SQUID with HTS thin films in flip-chip geometry, characteristics such as effective area and 1/f noise profile of the SQUID were successfully improved. By installing the covered SQUID in a magnetic contaminant detection system, it was demonstrated that the system can detect a tungsten ball of 15μm in diameter with a signal to noise ratio of about 2.

DOI
10.1016/j.phpro.2012.06.059

Related papers

Operation of high-temperature rf SQUID magnetometers using dielectric SrTiO3 resonators

Y. Zhang, M. Gottschlich, Helmut Soltner +4 more

The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.

Applied Physics Letters•Nov 20, 1995•16 citations

Substrate step-edge YBa2Cu3O7 rf SQUIDs

K.P. Daly, William D. Dozier, John F. Burch +4 more

We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.

Applied Physics Letters•Feb 4, 1991•133 citations

Characteristics of dielectric resonators for high-transition-temperature radio frequency superconducting quantum interference devices

Ji Gao, Yang Tao, Ma Ping +1 more

At present, the high-transition-temperature radio frequency superconducting quantum interference device (High- T c RF SQUID) is usually coupled to a dielectric resonator which is a standard 10 mm×10 mm× 1 mm SrTiO3 (STO) substrate with a YBa2Cu3O7-δ (YBCO) thin-film flux focuser deposited on it. The dielectric resonator for the High- Tc RF SQUID has a high quality factor and a resonant frequency in the microwave range. In order to find out the effect of the flux focuser’s geometry on the dielectric resonator’s resonant frequency, we used ANSOFT high frequency structure simulator (ANSOFT HFSS) to simulate the resonance characteristics of some dielectric resonators with different flux focuser geometries. Our simulation results show that when the width of the flux focuser’s slit increases or the radius of the flux focuser’s inner hole decreases, the dielectric resonator’s resonant frequency increases. To estimate the reliability of our simulation results, we selectively prepared a few dielectric resonators and measured their resonance characteristics. The experimental results are virtually consistent with the simulation results. Our study shows that changing the flux focuser geometry is an effective way to adjust the dielectric resonator’s resonant frequency.

Acta Physica Sinica•Jan 1, 2010•6 citations

High-Tc superconducting detector for highly-sensitive microwave magnetometry

F. Couëdo, Eliana Recoba Pawlowski, Julien Kermorvant +8 more

We have fabricated arrays of High-Tc Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive detectors for Radio Frequency (RF) waves. These subwavelength size devices known as Superconducting Quantum Interference Filters (SQIFs) detect the magnetic component of the electromagnetic field. We used a scalable ion irradiation technique to pattern the circuits and engineer the Josephson junctions needed to make SQUIDs. Here, we report on a 300 SQUID series array with the loop area ranging from 6 to 60 μm2, folded in a meander line covering a 3.5 mm × 120 μm substrate area, made out of a 150 nm thick YBa2Cu3O7 film. Operating at a temperature of T = 66 K in an unshielded magnetic environment under low DC bias current (I = 60 μA) and a DC magnetic field (B = 3 μT), this SQIF can detect a magnetic field of a few picoteslas at a frequency of 1.125 GHz, which corresponds to a sensitivity of a few hundreds of fT/Hz and shows a linear response over 7 decades in RF power. This work is a promising approach for the realization of low dissipative subwavelength gigahertz magnetometers.

arXiv:1901.08786•Applied Physics Letters•May 13, 2019•27 citations

Operation of high-sensitivity radio frequency superconducting quantum interference device magnetometers with superconducting coplanar resonators at 77 K

Y. Zhang, W. Zander, Jürgen Schubert +6 more

We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.

Applied Physics Letters•Aug 4, 1997•54 citations

Simulation of dielectric resonator for a high-Tcradio frequency superconducting quantum interference device

Ji Gao, Yang Tao, Ping Ma +1 more

Nowadays, the high-critical-temperature radio frequency superconducting quantum interference device (high- T c rf SQUID) is usually coupled to a dielectric resonator that is a standard 10 × 10 × 1 mm 3 SrTiO 3 (STO) substrate with a YBa 2 Cu 3 O 7−δ (YBCO) thin-film flux focuser deposited on it. Recently, we have simulated a dielectric resonator for the high- T c rf SQUID by using the ANSOFT High Frequency Structure Simulator (ANSOFT HFSS). We simulate the resonant frequency and the quality factor of our dielectric resonator when it is unloaded or matches a 50-Ω impedance. The simulation results are quite close to the practical measurements. Our study shows that ANSOFT HFSS is quite suitable for simulating the dielectric resonator used for the high- T c rf SQUID. Therefore, we think the ANSOFT HFSS can be very helpful for investigating the characteristics of dielectric resonators for high- T c rf SQUIDs.

Chinese Physics B•Jun 1, 2010•6 citations
Integrated high-temperature superconductor (HTS) radio-frequency (rf) superconducting quantum interference devices (SQUIDs) based on a bicrystal SrTiO3 substrate was investigated for application to magnetic contaminant detection. By covering a wide superconducting weak link and/or a slit of the YBa2Cu3O7-x SQUID with HTS thin films in flip-chip geometry, characteristics such as effective area and 1/f noise profile of the SQUID were successfully improved. By installing the covered SQUID in a magnetic contaminant detection system, it was demonstrated that the system can detect a tungsten ball of 15μm in diameter with a signal to noise ratio of about 2.
The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.
We have developed a technique which permits high-yield fabrication of microbridges and low noise YBa2Cu3O7 superconducting quantum interference devices (SQUIDs) in epitaxial thin films. These SQUIDs operate over a wide temperature range extending from 4 K to close to the superconducting transition temperature. Measurements of an rf SQUID operating at 77 K give a peak-to-peak flux sensitivity of 36 μV/Φ0 and a flux noise at 10 Hz of 1.5× 10−4 Φ0/√Hz. Device yields over 80% have been obtained.
At present, the high-transition-temperature radio frequency superconducting quantum interference device (High- T c RF SQUID) is usually coupled to a dielectric resonator which is a standard 10 mm×10 mm× 1 mm SrTiO3 (STO) substrate with a YBa2Cu3O7-δ (YBCO) thin-film flux focuser deposited on it. The dielectric resonator for the High- Tc RF SQUID has a high quality factor and a resonant frequency in the microwave range. In order to find out the effect of the flux focuser’s geometry on the dielectric resonator’s resonant frequency, we used ANSOFT high frequency structure simulator (ANSOFT HFSS) to simulate the resonance characteristics of some dielectric resonators with different flux focuser geometries. Our simulation results show that when the width of the flux focuser’s slit increases or the radius of the flux focuser’s inner hole decreases, the dielectric resonator’s resonant frequency increases. To estimate the reliability of our simulation results, we selectively prepared a few dielectric resonators and measured their resonance characteristics. The experimental results are virtually consistent with the simulation results. Our study shows that changing the flux focuser geometry is an effective way to adjust the dielectric resonator’s resonant frequency.
We have fabricated arrays of High-Tc Superconducting Quantum Interference Devices (SQUIDs) with randomly distributed loop sizes as sensitive detectors for Radio Frequency (RF) waves. These subwavelength size devices known as Superconducting Quantum Interference Filters (SQIFs) detect the magnetic component of the electromagnetic field. We used a scalable ion irradiation technique to pattern the circuits and engineer the Josephson junctions needed to make SQUIDs. Here, we report on a 300 SQUID series array with the loop area ranging from 6 to 60 μm2, folded in a meander line covering a 3.5 mm × 120 μm substrate area, made out of a 150 nm thick YBa2Cu3O7 film. Operating at a temperature of T = 66 K in an unshielded magnetic environment under low DC bias current (I = 60 μA) and a DC magnetic field (B = 3 μT), this SQIF can detect a magnetic field of a few picoteslas at a frequency of 1.125 GHz, which corresponds to a sensitivity of a few hundreds of fT/Hz and shows a linear response over 7 decades in RF power. This work is a promising approach for the realization of low dissipative subwavelength gigahertz magnetometers.
We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.
Nowadays, the high-critical-temperature radio frequency superconducting quantum interference device (high- T c rf SQUID) is usually coupled to a dielectric resonator that is a standard 10 × 10 × 1 mm 3 SrTiO 3 (STO) substrate with a YBa 2 Cu 3 O 7−δ (YBCO) thin-film flux focuser deposited on it. Recently, we have simulated a dielectric resonator for the high- T c rf SQUID by using the ANSOFT High Frequency Structure Simulator (ANSOFT HFSS). We simulate the resonant frequency and the quality factor of our dielectric resonator when it is unloaded or matches a 50-Ω impedance. The simulation results are quite close to the practical measurements. Our study shows that ANSOFT HFSS is quite suitable for simulating the dielectric resonator used for the high- T c rf SQUID. Therefore, we think the ANSOFT HFSS can be very helpful for investigating the characteristics of dielectric resonators for high- T c rf SQUIDs.