Optics Letters

Coherence time measurements using a single detector with variable time resolution

Marc Aßmann, M. Bayer

Published Jul 4, 2012• 6 citations
Publisher

Abstract

We present a simple technique for measuring coherence times for stationary light fields using a single detector with tunable time resolution. By measuring the equal-time second-order correlation function at varying instrument response functions it is possible to determine the coherence time and also the shape of the temporal decay without the need to record time-resolved data. The technique is demonstrated for pseudothermal light. Possible applications for dynamic light scattering and photon statistics measurements are discussed.

DOI
10.1364/ol.37.002811

Related papers

Measurement of the second-order coherence of pseudothermal light

Tom Kuusela

We describe photon statistics experiments using pseudothermal light that can be performed in an undergraduate physics laboratory. We examine the light properties in terms of a second-order coherence function, as determined either by measuring the light intensity as a function of time or via coincidence analysis of a pair of photon detectors. We determine the coherence time and intensity distribution of the pseudothermal light source that exhibits either Gaussian or non-Gaussian statistics as a function of their optical parameters, and then compare the results with theoretical predictions. The simple photodiode method can be used for the qualitative analysis of the coherence time, but more accurate measurements are achieved using the coincidence method.

American Journal of Physics•Mar 21, 2017•21 citations

Simulation of temporal second-order correlation function based on Monte Carlo algorithm

Yongsheng Hu, Tengfei Ma, Danqun Mao +5 more

The second-order correlation function of photons is the primary means to quantitatively describe the second-order coherence of a light field. In contrast to the stationary second-order correlation function, the temporal second-order correlation function can be used to study the second-order coherence of a transient light field. Based on the Monte Carlo algorithm, we carried out theoretical simulation on the temporal second-order correlation function from the perspective of photon statistics. By introducing experimental factors into the simulation, such as intensity jitter of the light field and time resolution of the instruments, the effects of imperfect experimental conditions on the measurement of second-order correlation function have also been elucidated. Our results provide theoretical guidance and analysis methods for experimental measurements on the second-order coherence of light fields.

Frontiers of Physics•Jan 1, 2025•0 citations

Novel technique for photon correlation measurements at high photon rates and resolutions

Dimitar Stoyanov

A novel technique for photon correlation measurements, based on the excitation of a resonant system by photon-detector single pulses, analog/digital sampling, and deconvolution, has been developed and analyzed experimentally and by computer simulations. The measured correlation function is expressed by a convolution of the true photon correlation function of the optical field and a well-defined, noiseless resonator correlation function. The effect of detector statistics is reduced to the contribution of two integral parameters—the total single-pulse charge and the jitter of single-pulse centers. Good performance of this technique is demonstrated at high photon rates and resolutions, where the well-known photon-counting or single-quantum methods are ineffective. The novel technique offers linear recording of photocount time series without dead-time effects. The temporal resolution is defined by the sampling step of the analog/digital converter. The retrieval error does not exceed 1 to 3% at count rates higher than 1 GHz and single-pulse durations larger than the resolution cell. This technique can be effectively applied in photon correlation measurements of high dynamic optical fields.

Optical Engineering•Jun 1, 1997•3 citations

Measurement of coherence time by fourth-order Interference

Z. Y. Ou, E. C. Gage, Brian E. Magill +1 more

By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Fourth-order interference technique for determining the coherence time of a light beam

Z. Y. Ou, E. C. Gage, Brian E. Magill +1 more

A new experimental procedure for determining the (second-order) coherence time of a light beam is described that is based on a combination of conventional interferometry with an intensity-correlation technique. It permits measurements of coherence times that are several orders of magnitude shorter than the resolving times of the detectors, which ordinarily limit correlation measurements. The validity of the method is demonstrated by an experiment in which the transverse fluorescent light from a dye laser is measured.

Journal of the Optical Society of America B•Jan 1, 1989•65 citations

Calibration of second-order correlation functions for nonstationary sources with a multistart, multistop time-to-digital converter

Wonshik Choi, Moonjoo Lee, Ye-Ryoung Lee +6 more

A novel high-throughput second-order correlation measurement system is developed that records and makes use of all the arrival times of photons detected at both start and stop detectors. This system is suitable, particularly for a light source having a high photon flux and a long coherence time, since it is more efficient than conventional methods by an amount equal to the product of the count rate and the correlation time of the light source. We have used this system in carefully investigating the dead time effects of detectors and photon counters on the second-order correlation function in the two-detector configuration. For a nonstationary light source, a distortion of the original signal was observed at high photon flux. A systematic way of calibrating the second-order correlation function has been devised by introducing the concept of an effective dead time of the entire measurement system.

arXiv:physics/0411212•Review of Scientific Instruments•Jul 21, 2005•9 citations
We present a simple technique for measuring coherence times for stationary light fields using a single detector with tunable time resolution. By measuring the equal-time second-order correlation function at varying instrument response functions it is possible to determine the coherence time and also the shape of the temporal decay without the need to record time-resolved data. The technique is demonstrated for pseudothermal light. Possible applications for dynamic light scattering and photon statistics measurements are discussed.
We describe photon statistics experiments using pseudothermal light that can be performed in an undergraduate physics laboratory. We examine the light properties in terms of a second-order coherence function, as determined either by measuring the light intensity as a function of time or via coincidence analysis of a pair of photon detectors. We determine the coherence time and intensity distribution of the pseudothermal light source that exhibits either Gaussian or non-Gaussian statistics as a function of their optical parameters, and then compare the results with theoretical predictions. The simple photodiode method can be used for the qualitative analysis of the coherence time, but more accurate measurements are achieved using the coincidence method.
The second-order correlation function of photons is the primary means to quantitatively describe the second-order coherence of a light field. In contrast to the stationary second-order correlation function, the temporal second-order correlation function can be used to study the second-order coherence of a transient light field. Based on the Monte Carlo algorithm, we carried out theoretical simulation on the temporal second-order correlation function from the perspective of photon statistics. By introducing experimental factors into the simulation, such as intensity jitter of the light field and time resolution of the instruments, the effects of imperfect experimental conditions on the measurement of second-order correlation function have also been elucidated. Our results provide theoretical guidance and analysis methods for experimental measurements on the second-order coherence of light fields.
A novel technique for photon correlation measurements, based on the excitation of a resonant system by photon-detector single pulses, analog/digital sampling, and deconvolution, has been developed and analyzed experimentally and by computer simulations. The measured correlation function is expressed by a convolution of the true photon correlation function of the optical field and a well-defined, noiseless resonator correlation function. The effect of detector statistics is reduced to the contribution of two integral parameters—the total single-pulse charge and the jitter of single-pulse centers. Good performance of this technique is demonstrated at high photon rates and resolutions, where the well-known photon-counting or single-quantum methods are ineffective. The novel technique offers linear recording of photocount time series without dead-time effects. The temporal resolution is defined by the sampling step of the analog/digital converter. The retrieval error does not exceed 1 to 3% at count rates higher than 1 GHz and single-pulse durations larger than the resolution cell. This technique can be effectively applied in photon correlation measurements of high dynamic optical fields.
By using an intensity correlation, or photon coincidence, technique and a Mach-Zehnder interferometer with artificially applied phase fluctuations in one arm, we measured the coherence time of a thermal light beam. The light was derived from the filtered fluorescence of a rhodamine 6G dye solution. The two-photon coincidence rate was measured as a function of path difference and was found to dip 50% when the two arms of the interferometer are balanced. The coherence time of ~100 fs is determined from the measured width of the dip and is consistent with the passband of the filters. The method does not require the stability needed in second-order interference measurements, and its time resolution can be much shorter than that of the photodetectors. The theory of this type of fourth-order interference technique is discussed.
A new experimental procedure for determining the (second-order) coherence time of a light beam is described that is based on a combination of conventional interferometry with an intensity-correlation technique. It permits measurements of coherence times that are several orders of magnitude shorter than the resolving times of the detectors, which ordinarily limit correlation measurements. The validity of the method is demonstrated by an experiment in which the transverse fluorescent light from a dye laser is measured.
A novel high-throughput second-order correlation measurement system is developed that records and makes use of all the arrival times of photons detected at both start and stop detectors. This system is suitable, particularly for a light source having a high photon flux and a long coherence time, since it is more efficient than conventional methods by an amount equal to the product of the count rate and the correlation time of the light source. We have used this system in carefully investigating the dead time effects of detectors and photon counters on the second-order correlation function in the two-detector configuration. For a nonstationary light source, a distortion of the original signal was observed at high photon flux. A systematic way of calibrating the second-order correlation function has been devised by introducing the concept of an effective dead time of the entire measurement system.