Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The Journal of Chemical Physics

Low-Field Nuclear Magnetic Resonance of Coupled Spin—One-Half Particles

Don D. Thompson, Robert James Brown

Published Nov 1, 1961• 10 citations
Publisher
DOI
10.1063/1.1732162

Related papers

Magnetic Double Resonance of a System of Two Spin- nuclei

Pietro Bucci, M Martinelli, S. Santucci +1 more

Journal of Magnetic Resonance (1969)•Mar 1, 1972•10 citations

Many-particle entanglement in multiple quantum nuclear-magnetic-resonance spectroscopy

Serge I. Doronin, Edward B. Fel’dman, I. D. Lazarev

We use multiple quantum (MQ) nuclear magnetic resonance dynamics of a gas of spin-carrying molecules in nanocavities at high and low temperatures for an investigation of many-particle entanglement. A distribution of MQ NMR intensities is obtained at high and low temperatures in a system of 201 spins $\frac{1}{2}$. The second moment of the distribution, which provides a lower bound on the quantum Fisher information, sheds light on the many-particle entanglement in the system. The dependence of the many-particle entanglement on the temperature is investigated. Almost all spins are entangled at low temperatures.

arXiv:2001.10607•Physical Review A•Aug 22, 2019•19 citations

Low-energy dynamics of a magnetic impurity in a quantum spin chain: Role of local levels

Andrei A. Zvyagin

The characteristics of the nuclear magnetic resonance (NMR), the contributions to the spin-lattice relaxation rate, and Knight shift of the resonance position are calculated exactly for a model spin-$1/2$ $XY$ chain with the magnetic impurity. It is shown that the deviations of the impurity's coupling to the chain and the effective impurity's $g$ factor from the values in the host spin chain yield special features in the temperature and magnetic field behavior for these NMR characteristics. The role of impurity-induced local levels in the NMR low-energy spin dynamics of spin chains is determined.

Physical Review B•Apr 20, 2012•5 citations

Nuclear Magnetic Resonance

David S. Simon

Undergraduate texts in physics•Jan 1, 2025•1 citation

Nuclear magnetic resonance of trapped molecules

春雄 中島

•Jan 1, 1966•0 citations

Architecture to achieve nuclear magnetic resonance spectroscopy with a superconducting flux qubit

Koichiro Miyanishi, Yuichiro Matsuzaki, Hiraku Toida +4 more

We theoretically analyze the performance of the nuclear magnetic resonance (NMR) spectroscopy with a superconducting flux qubit (FQ). Such NMR with the FQ is attractive because of the possibility to detect the relatively small number of nuclear spins in a local region ($\ensuremath{\approx}\ensuremath{\mu}\mathrm{m}$) with low temperatures ($\ensuremath{\approx}\mathrm{mK}$) and low magnetic fields ($\ensuremath{\approx}\mathrm{mT}$), in which other types of quantum sensing schemes cannot easily be accessed. A sample containing nuclear spins is directly attached on the FQ, and the FQ is used as a magnetometer to detect magnetic fields from the nuclear spins. Especially, we consider two types of approaches to NMR with the FQ. One of them is to use spatially inhomogeneous excitations of the nuclear spins, which are induced by a spatially asymmetric driving with radio-frequency (rf) pulses. Such an inhomogeneity causes a change in the dc magnetic flux penetrating a loop of the FQ, which can be detected by a standard Ramsey measurement on the FQ. The other approach is to use a dynamical decoupling on the FQ to measure ac magnetic fields induced by Larmor precession of the nuclear spins. In this case, neither a spin excitation nor a spin polarization is required since the signal comes from fluctuating magnetic fields of the nuclear spins. We calculate the minimum detectable density (number) of the nuclear spins for the FQ with experimentally feasible parameters. We show that the minimum detectable density (number) of the nuclear spins with these approaches is around ${10}^{21}/{\mathrm{cm}}^{3}$ (${10}^{8}$) with an accumulation time of 1 s.

arXiv:1906.07386•Physical Review A•May 1, 2020•5 citations
We use multiple quantum (MQ) nuclear magnetic resonance dynamics of a gas of spin-carrying molecules in nanocavities at high and low temperatures for an investigation of many-particle entanglement. A distribution of MQ NMR intensities is obtained at high and low temperatures in a system of 201 spins 12\frac{1}{2}21​. The second moment of the distribution, which provides a lower bound on the quantum Fisher information, sheds light on the many-particle entanglement in the system. The dependence of the many-particle entanglement on the temperature is investigated. Almost all spins are entangled at low temperatures.
The characteristics of the nuclear magnetic resonance (NMR), the contributions to the spin-lattice relaxation rate, and Knight shift of the resonance position are calculated exactly for a model spin-1/21/21/2 XYXYXY chain with the magnetic impurity. It is shown that the deviations of the impurity's coupling to the chain and the effective impurity's ggg factor from the values in the host spin chain yield special features in the temperature and magnetic field behavior for these NMR characteristics. The role of impurity-induced local levels in the NMR low-energy spin dynamics of spin chains is determined.
We theoretically analyze the performance of the nuclear magnetic resonance (NMR) spectroscopy with a superconducting flux qubit (FQ). Such NMR with the FQ is attractive because of the possibility to detect the relatively small number of nuclear spins in a local region ($\ensuremath{\approx}\ensuremath{\mu}\mathrm{m}$) with low temperatures ($\ensuremath{\approx}\mathrm{mK}$) and low magnetic fields ($\ensuremath{\approx}\mathrm{mT}$), in which other types of quantum sensing schemes cannot easily be accessed. A sample containing nuclear spins is directly attached on the FQ, and the FQ is used as a magnetometer to detect magnetic fields from the nuclear spins. Especially, we consider two types of approaches to NMR with the FQ. One of them is to use spatially inhomogeneous excitations of the nuclear spins, which are induced by a spatially asymmetric driving with radio-frequency (rf) pulses. Such an inhomogeneity causes a change in the dc magnetic flux penetrating a loop of the FQ, which can be detected by a standard Ramsey measurement on the FQ. The other approach is to use a dynamical decoupling on the FQ to measure ac magnetic fields induced by Larmor precession of the nuclear spins. In this case, neither a spin excitation nor a spin polarization is required since the signal comes from fluctuating magnetic fields of the nuclear spins. We calculate the minimum detectable density (number) of the nuclear spins for the FQ with experimentally feasible parameters. We show that the minimum detectable density (number) of the nuclear spins with these approaches is around 1021/cm3{10}^{21}/{\mathrm{cm}}^{3}1021/cm3 (108{10}^{8}108) with an accumulation time of 1 s.