Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Cryogenics

A method for studying the properties of a superconducting quantum detector of magnetic flux

V. A. Kozlov, N.D. Koslova, E.M. Savitskii, I.I. Bykov

Published Apr 1, 1976• 0 citations
Publisher
DOI
10.1016/0011-2275(76)90269-1

Related papers

Method for investigating the properties of a superconducting quantum magnetic-flux meter

V. A. Kozlov, N.D. Kozlova, E.M. Savitskii +1 more

•Jan 1, 1975•0 citations

Improving Superconducting Resonators in Magnetic Fields by Reduced Field Focussing and Engineered Flux Screening

Daniel Bothner, D. Wiedmaier, B. Ferdinand +2 more

Superconducting microwave circuits are among the most powerful tools for quantum information science and sensor applications. To realize their full potential in hybrid quantum systems and spin-resonance detectors, strategies are needed to allow these circuits to operate unaffected by external magnetic fields. The authors implement two new approaches to reduce the sensitivity of superconducting coplanar microwave resonators to perpendicular magnetic fields. Combining built-in flux screening loops with reduction of geometry-induced field-focusing, the authors demonstrate a significant increase in magnetic-field resilience and stability of resonator properties.

arXiv:1707.01936•Physical Review Applied•Sep 26, 2017•21 citations

Laser switch for stroboscopic read-out of magnetic flux

Marco Ferrara, Pasquale Carelli, F. Chiarello +3 more

We have realized and tested a fast stroboscopic detector for magnetic flux measurements. The key element of our detector is a hysteretic dc superconducting quantum interference device (SQUID). Stroboscopic read-out of the magnetic flux coupled with the SQUID is accomplished by biasing the SQUID with fast current pulses. The shorter these pulses, the more stroboscopic and less invasive the measurement we are performing. In order to reduce the duration of the current pulses, we take advantage of the superconducting-normal transition induced by laser light in thin superconducting films. The interaction of laser light with superconducting thin films has been investigated thoroughly in the past and many applications have been proposed which rely on the fast typical times with which superconductivity is broken and a resistive behavior arises. We have measured a threshold resolution of 6.9mΦ0 at 4.2 K, and this value corresponds to the thermodynamic limit of the SQUID. The detector has been accurately characterized: An improved and more sensitive version might prove useful for quantum mechanics and quantum computation experiments, for example, in detecting the state of flux qubits.

Review of Scientific Instruments•May 21, 2004•0 citations

Magnetic measurements using a superconducting quantum magnetic-flux meter

N. V. Zavaritskiǐ, Legkostupov

•Jan 1, 1973•0 citations

Magnetic measurements with a superconducting quantum magnetic flux meter

N. V. Zavaritskiǐ, Михаил Семенович Легкоступов

Cryogenics•Jan 1, 1974•1 citation

Magneto-optical detection of single flux quantum signals in superconducting quantum interference device

Hironaru Murakami, Ryohei Kitamura, Iwao Kawayama +1 more

The properties of an YBa2Cu3O7−d superconducting quantum interference device (SQUID) have been evaluated magneto-optically and electrically. It was found that the operating characteristics of the SQUID observed by means of the magneto-optical (MO) method show a good consistency with those measured by the electrical method. Furthermore, we have succeeded in the MO detection of local magnetic signals corresponding to the single flux quantum pulses generated in the SQUID loop applied with an external pulsed magnetic field. These results indicate that the MO probe has the potential to be applied to an optical output interface for superconducting magnetic flux devices.

Applied Physics Letters•Nov 9, 2009•0 citations
Superconducting microwave circuits are among the most powerful tools for quantum information science and sensor applications. To realize their full potential in hybrid quantum systems and spin-resonance detectors, strategies are needed to allow these circuits to operate unaffected by external magnetic fields. The authors implement two new approaches to reduce the sensitivity of superconducting coplanar microwave resonators to perpendicular magnetic fields. Combining built-in flux screening loops with reduction of geometry-induced field-focusing, the authors demonstrate a significant increase in magnetic-field resilience and stability of resonator properties.
We have realized and tested a fast stroboscopic detector for magnetic flux measurements. The key element of our detector is a hysteretic dc superconducting quantum interference device (SQUID). Stroboscopic read-out of the magnetic flux coupled with the SQUID is accomplished by biasing the SQUID with fast current pulses. The shorter these pulses, the more stroboscopic and less invasive the measurement we are performing. In order to reduce the duration of the current pulses, we take advantage of the superconducting-normal transition induced by laser light in thin superconducting films. The interaction of laser light with superconducting thin films has been investigated thoroughly in the past and many applications have been proposed which rely on the fast typical times with which superconductivity is broken and a resistive behavior arises. We have measured a threshold resolution of 6.9mΦ0 at 4.2 K, and this value corresponds to the thermodynamic limit of the SQUID. The detector has been accurately characterized: An improved and more sensitive version might prove useful for quantum mechanics and quantum computation experiments, for example, in detecting the state of flux qubits.
The properties of an YBa2Cu3O7−d superconducting quantum interference device (SQUID) have been evaluated magneto-optically and electrically. It was found that the operating characteristics of the SQUID observed by means of the magneto-optical (MO) method show a good consistency with those measured by the electrical method. Furthermore, we have succeeded in the MO detection of local magnetic signals corresponding to the single flux quantum pulses generated in the SQUID loop applied with an external pulsed magnetic field. These results indicate that the MO probe has the potential to be applied to an optical output interface for superconducting magnetic flux devices.