Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Quantum Theory of Optical Homodyne and Heterodyne Detection

Matthew J. Collett, R. Loudon, Crispin W. Gardiner

Published Jun 1, 1987• 171 citations
Publisher

Abstract

The theory of balanced homodyne and heterodyne detection is developed for inputs in which the signal field is in an arbitrary quantum state and the local-oscillator field is in a highly excited coherent state. Exact expressions are derived for the photocount moment-generating functions in the special case of a coherent signal. For more general signals, the first two moments of the photocount probability distribution are determined. The moments are evaluated for the examples of a coherent signal with a chaotic noise component, and for squeezed light derived from a degenerate and from a non-degenerate parametric amplifier. The corresponding moments for direct detection are obtained so that comparisons can be made. The Kelley-Kleiner photocount distribution formula is adapted to balanced detection schemes. Light beams are characterized throughout by their energy fluxes, and the theory accordingly describes steady-state experiments.

DOI
10.1080/09500348714550811

Related papers

Noise in homodyne and heterodyne detection

Horace P. Yuen, Vincent W. S. Chan

Quantum-mechanical calculations of the mean-square fluctuation spectra in optical homodyning and heterodyning are made for arbitrary input and local-oscillator quantum states. In addition to the unavoidable quantum fluctuations, it is shown that excess noise from the local oscillator always affects homodyning and, when it is broadband, also heterodyning. Both the quantum and the excess noise of the local oscillator can be eliminated by coherent subtraction of the two outputs of a 50-50 beam splitter. This result also demonstrates the fact that the basic quantum noise in homodyning and heterodyning is signal quantum fluctuation, not local-oscillator shot noise.

Optics Letters•Mar 1, 1983•741 citations

Experimental study of balanced optical homodyne and heterodyne detection by controlling sideband modulation

Li We

We experimentally study optical homodyne and heterodyne detections with the same setup, which is flexible to manipulate the signal sideband modulation. When the modulation only generates a single signal sideband, the light field measurement by mixing the single sideband at ω0 ±? with a strong local oscillator at the carrier frequency ω0on a beam splitter becomes balanced heterodyne detection. When two signal sidebands at ω0 ±? are generated and the relative phase of the two sidebands is locked, this measurement corresponds to optical balanced homodyne detection. With this setup, we may confirm directly that the signal-to-noise ratio with heterodyne detection is two-fold worse than that with homodyne detection. This work will have important applications in quantum state measurement and quantum information.

Science in China. Series G, Physics, mechanics & astronomy/Science in China. Series G, Physics, Mechanics & Astronomy•Jan 1, 2015•0 citations

Direct detection of Gaussian state light

Jeffrey H. Shapiro, Ke-Xun Sun

The quantum theory of photodetection is applied to the direct detection of multi-mode Gaussian-state light, with particular attention to the mean photocurrent and the photocurrent noise spectrum. Gaussian-state light comprises squeezed-state light plus additional classical Gaussian noise. By extending the familiar Gaussian moment-factoring formula of classical statistics to the antinormally ordered characteristic function of Gaussian-state light, the first and second moment photocurrent statistics for such illumination are shown to be completely characterized by knowledge of the mean function, the phase-sensitive correlation function, and the normally ordered correlation of the input light. The theory delineates the condition under which the strong-mean-field approximation is applicable to direct detection of such beams, i.e., it tells us when a direct detector yields the same noise spectrum as that of an in-phase homodyne detector. Numerical results are presented for the noise spectra of a squeezed amplifier, i.e., an optical parametric amplifier with signal-injection-induced gain saturation.

Annual Meeting Optical Society of America•Jan 1, 1992•0 citations

Noise in homodyne and heterodyne detection

Horace P. Yuen, Vincent W. S. Chan

Quantum noise in optical heterodyning and homodyning, usually analyzed under the assumption that the photodetector output is conditionally Poisson,1,2 is frequently supposed to arise from local oscillator (LO) shot noise. However, a fully quantum mechanical analysis from Yuen and Shapiro3 has shown that it actually arises from the signal quantum fluctuation; in particular homodyning and heterodyning are realizations of abstract quantum measurements of the field quadratures. We analyze the effect of LO noise, both quantum and excess noise, on homodyne and heterodyne detection. For conventional input light, i.e., fields in coherent states or their random superpositions, we demonstrate how a conditionally Poisson calculation would yield the correct answer but incorrect interpretation for the detection quantum noise.

Conference on Lasers and Electro-Optics•Jan 1, 1983•13 citations

Homodyne and heterodyne statistics of squeezed light from parametric oscillators

Reeta Vyas

We discuss homodyne and heterodyne statistics when squeezed light from a parametric oscillator is mixed with coherent light from a local oscillator. We also consider the case where the fields or the intensities of the two nondegenerate beams from a parametric oscillator are combined. By using a dynamic model of these beams we discuss photon sequences underlying these beams in terms of photoelectric pulse sequences recorded by a detector. Analytic expressions for quantities directly measurable in photon counting experiments are derived, using the method developed in our earlier investigations.1

Annual Meeting Optical Society of America•Jan 1, 1991•0 citations

Homodyne-like detection scheme based on photon-number-resolving detectors

Alessia Allevi, Matteo Bina, Stefano Olivares +1 more

Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.

International Journal of Quantum Information•Dec 1, 2017•13 citations
The theory of balanced homodyne and heterodyne detection is developed for inputs in which the signal field is in an arbitrary quantum state and the local-oscillator field is in a highly excited coherent state. Exact expressions are derived for the photocount moment-generating functions in the special case of a coherent signal. For more general signals, the first two moments of the photocount probability distribution are determined. The moments are evaluated for the examples of a coherent signal with a chaotic noise component, and for squeezed light derived from a degenerate and from a non-degenerate parametric amplifier. The corresponding moments for direct detection are obtained so that comparisons can be made. The Kelley-Kleiner photocount distribution formula is adapted to balanced detection schemes. Light beams are characterized throughout by their energy fluxes, and the theory accordingly describes steady-state experiments.
Quantum-mechanical calculations of the mean-square fluctuation spectra in optical homodyning and heterodyning are made for arbitrary input and local-oscillator quantum states. In addition to the unavoidable quantum fluctuations, it is shown that excess noise from the local oscillator always affects homodyning and, when it is broadband, also heterodyning. Both the quantum and the excess noise of the local oscillator can be eliminated by coherent subtraction of the two outputs of a 50-50 beam splitter. This result also demonstrates the fact that the basic quantum noise in homodyning and heterodyning is signal quantum fluctuation, not local-oscillator shot noise.
We experimentally study optical homodyne and heterodyne detections with the same setup, which is flexible to manipulate the signal sideband modulation. When the modulation only generates a single signal sideband, the light field measurement by mixing the single sideband at ω0 ±? with a strong local oscillator at the carrier frequency ω0on a beam splitter becomes balanced heterodyne detection. When two signal sidebands at ω0 ±? are generated and the relative phase of the two sidebands is locked, this measurement corresponds to optical balanced homodyne detection. With this setup, we may confirm directly that the signal-to-noise ratio with heterodyne detection is two-fold worse than that with homodyne detection. This work will have important applications in quantum state measurement and quantum information.
The quantum theory of photodetection is applied to the direct detection of multi-mode Gaussian-state light, with particular attention to the mean photocurrent and the photocurrent noise spectrum. Gaussian-state light comprises squeezed-state light plus additional classical Gaussian noise. By extending the familiar Gaussian moment-factoring formula of classical statistics to the antinormally ordered characteristic function of Gaussian-state light, the first and second moment photocurrent statistics for such illumination are shown to be completely characterized by knowledge of the mean function, the phase-sensitive correlation function, and the normally ordered correlation of the input light. The theory delineates the condition under which the strong-mean-field approximation is applicable to direct detection of such beams, i.e., it tells us when a direct detector yields the same noise spectrum as that of an in-phase homodyne detector. Numerical results are presented for the noise spectra of a squeezed amplifier, i.e., an optical parametric amplifier with signal-injection-induced gain saturation.
Quantum noise in optical heterodyning and homodyning, usually analyzed under the assumption that the photodetector output is conditionally Poisson,1,2 is frequently supposed to arise from local oscillator (LO) shot noise. However, a fully quantum mechanical analysis from Yuen and Shapiro3 has shown that it actually arises from the signal quantum fluctuation; in particular homodyning and heterodyning are realizations of abstract quantum measurements of the field quadratures. We analyze the effect of LO noise, both quantum and excess noise, on homodyne and heterodyne detection. For conventional input light, i.e., fields in coherent states or their random superpositions, we demonstrate how a conditionally Poisson calculation would yield the correct answer but incorrect interpretation for the detection quantum noise.
We discuss homodyne and heterodyne statistics when squeezed light from a parametric oscillator is mixed with coherent light from a local oscillator. We also consider the case where the fields or the intensities of the two nondegenerate beams from a parametric oscillator are combined. By using a dynamic model of these beams we discuss photon sequences underlying these beams in terms of photoelectric pulse sequences recorded by a detector. Analytic expressions for quantities directly measurable in photon counting experiments are derived, using the method developed in our earlier investigations.1
Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.