Journal of Physics B Atomic Molecular and Optical Physics

Detection of atoms in a beam: filtering of the atomic shot noise and velocity dispersion contribution

N. Dimarcq, C. Audoin

Published Jun 14, 1995• 5 citations
Publisher

Abstract

We calculate the contribution of the atomic shot noise in the detection of the laser-induced fluorescence signal emitted by atoms in a beam. We point out a filtering of such a contribution which is the consequence of the finite transit time of the atoms through the laser beam. Moreover, we demonstrate that the distribution of the atomic velocities in the beam induces an extra noise which degrades the measured signal-to-noise ratio and modifies the observed statistics of the fluorescence photons emitted by the whole interaction zone.

DOI
10.1088/0953-4075/28/11/008

Related papers

Assessment of a time-of-flight detection technique for measuring small velocities of cold atoms

Henrik Hagman, Peder Sjölund, S.J.H. Petra +4 more

A low noise time-of-flight detection system for laser cooled atoms has been constructed and incrementally optimized. Here, a thorough description of the construction is presented along with an analysis of the capabilities of the system. The quality of the detection (the resolution, the reproducibility, the sensitivity, etc.) is crucial for, e.g., the ability to see details in the velocity distribution profile, which is of interest for fundamental studies of statistical physics and of the laser cooling processes, and for detection of small initial velocities of an atomic cloud, important, e.g., when studying small drifts induced by Brownian motors and ratchets. We estimate the signal-to-noise ratio of our signal to be better than 1000:1 for a typical single shot, and we discuss the effect of the initial atomic cloud size, the probe size, and the effects of the wave packet spread during the fall time on the measured quantities. We show that the shape of the velocity distribution is well conserved during the mapping done in the detection, i.e., in the convolution with the probe beam, and that velocities as small as a few percent of the single photon recoil velocity can be resolved.

Journal of Applied Physics•Apr 15, 2009•10 citations

Imaging an atomic beam using fluorescence

何明, 王谨, 詹明生

A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed by a commercial CCD-camera, which is corresponding to the atomic state and velocity distribution. The detection scheme has a great utilization in the experiments of cold atoms and atomic optics.

Chinese Optics Letters•Jan 1, 2003•0 citations

Imaging an atomic beam using fluorescence

Ming He, Jin Wang, Mingsheng Zhan

A fluorescence detection scheme is applied to image an atomic beam. Using two laser diodes as the sources of detection light and pumping light respectively, the fluorescence image of the atomic beam is then observed by a commercial CCD-camera, which is corresponding to the atomic state and velocity distribution. The detection scheme has a great utilization in the experiments of cold atoms and atomic optics.

Chinese Optics Letters•Sep 20, 2003•3 citations

Detection and transit time measurements of individual sodium atoms diffusing in a helium flow by the laser resonance fluorescence correlation technique

Ci‐Ling Pan, She, C. Y.

This thesis describes the laser resonance fluorescence correlation technique for single-atom velocity measurement. Using this technique, we have detected individual sodium atoms diffusing through a laser beam in a slow helium flow. From the width of the fluorescence bursts detected, the transit time for the diffusing atom is determined. This is the first measurement of the motion of a single atom in a buffer gas. A probability analysis was developed which allowed us to estimate the average burst size of emitted fluorescence photons by an atom traversing the laser beam. All these results were in general agreement with the theoretical predictions. With improvements, we will be able to measure the velocity of a single-atom either in a flow or in a vacuum. By averaging over many sodium atoms, the diffusion coefficients of sodium atoms in helium and argon buffer gases were investigated using this technique. The measured diffusion coefficients were found to be in reasonable agreement with theoretical predictions and previous experimental results. To our knowledge, this is the first application of resonance fluorescence correlation technique to the measurement of diffusion coefficient of fast moving atoms in gases.

•Jan 1, 1979•0 citations

Laser-induced noise contribution due to imperfect atomic state preparation in an optically pumped caesium beam resonator

Gaëlle Lucas-Leclin, P. Cérez, N. Dimarcq

Imperfect atomic state preparation in an optically pumped beam resonator results in over-Poissonian fluctuations of the fluorescence emission of residual unpumped atoms. This excess noise is induced by the frequency noise of the pump laser. We evaluate it theoretically for a three-level atomic system interacting with a noisy laser field, and show that it is predominant within a large range of pumping efficiencies and laser linewidths for usual atomic fluxes. Experimentally, extra noise is detected from ratios of unpumped atoms as low as 0.01% of the atomic flux equal to . This noise source debases the short-term stability of an atomic clock in a flop-in configuration if the proportion of unpumped atoms exceeds 1% of the global atomic flux. In a flop-out configuration this excess noise would decrease the clock stability from a proportion of unpumped atoms of 0.01%.

Journal of Physics B Atomic Molecular and Optical Physics•Jan 1, 1999•12 citations

Observation of optical pumping effects in collinear atomic beam - laser beam(s) interaction

N. Bendali, H. T. Duong, J.M. Saint Jalm +1 more

The detection of optical resonances by observation of the fluorescence light emitted from a fast atomic beam of Na interacting with a collinear laser beam is limited in sensitivity by optical pumping processes. In the experiment reported here, we take advantage of the optical pumping by using a second collinear laser beam, achieving then a gain in fluorescence signal. The effects of the lasers power and polarization on line shapes have been studied in the single laser excitation case as well as in the two laser beams one.

Journal de physique•Jan 1, 1983•7 citations
We calculate the contribution of the atomic shot noise in the detection of the laser-induced fluorescence signal emitted by atoms in a beam. We point out a filtering of such a contribution which is the consequence of the finite transit time of the atoms through the laser beam. Moreover, we demonstrate that the distribution of the atomic velocities in the beam induces an extra noise which degrades the measured signal-to-noise ratio and modifies the observed statistics of the fluorescence photons emitted by the whole interaction zone.
A low noise time-of-flight detection system for laser cooled atoms has been constructed and incrementally optimized. Here, a thorough description of the construction is presented along with an analysis of the capabilities of the system. The quality of the detection (the resolution, the reproducibility, the sensitivity, etc.) is crucial for, e.g., the ability to see details in the velocity distribution profile, which is of interest for fundamental studies of statistical physics and of the laser cooling processes, and for detection of small initial velocities of an atomic cloud, important, e.g., when studying small drifts induced by Brownian motors and ratchets. We estimate the signal-to-noise ratio of our signal to be better than 1000:1 for a typical single shot, and we discuss the effect of the initial atomic cloud size, the probe size, and the effects of the wave packet spread during the fall time on the measured quantities. We show that the shape of the velocity distribution is well conserved during the mapping done in the detection, i.e., in the convolution with the probe beam, and that velocities as small as a few percent of the single photon recoil velocity can be resolved.
This thesis describes the laser resonance fluorescence correlation technique for single-atom velocity measurement. Using this technique, we have detected individual sodium atoms diffusing through a laser beam in a slow helium flow. From the width of the fluorescence bursts detected, the transit time for the diffusing atom is determined. This is the first measurement of the motion of a single atom in a buffer gas. A probability analysis was developed which allowed us to estimate the average burst size of emitted fluorescence photons by an atom traversing the laser beam. All these results were in general agreement with the theoretical predictions. With improvements, we will be able to measure the velocity of a single-atom either in a flow or in a vacuum. By averaging over many sodium atoms, the diffusion coefficients of sodium atoms in helium and argon buffer gases were investigated using this technique. The measured diffusion coefficients were found to be in reasonable agreement with theoretical predictions and previous experimental results. To our knowledge, this is the first application of resonance fluorescence correlation technique to the measurement of diffusion coefficient of fast moving atoms in gases.
Imperfect atomic state preparation in an optically pumped beam resonator results in over-Poissonian fluctuations of the fluorescence emission of residual unpumped atoms. This excess noise is induced by the frequency noise of the pump laser. We evaluate it theoretically for a three-level atomic system interacting with a noisy laser field, and show that it is predominant within a large range of pumping efficiencies and laser linewidths for usual atomic fluxes. Experimentally, extra noise is detected from ratios of unpumped atoms as low as 0.01% of the atomic flux equal to . This noise source debases the short-term stability of an atomic clock in a flop-in configuration if the proportion of unpumped atoms exceeds 1% of the global atomic flux. In a flop-out configuration this excess noise would decrease the clock stability from a proportion of unpumped atoms of 0.01%.
The detection of optical resonances by observation of the fluorescence light emitted from a fast atomic beam of Na interacting with a collinear laser beam is limited in sensitivity by optical pumping processes. In the experiment reported here, we take advantage of the optical pumping by using a second collinear laser beam, achieving then a gain in fluorescence signal. The effects of the lasers power and polarization on line shapes have been studied in the single laser excitation case as well as in the two laser beams one.