Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Journal of Quantum Electronics

Josephson junctions as radiation detectors from milli Hz to tera Hz frequencies

Donald McDonald

Published Sep 1, 1974• 0 citations
Publisher
DOI
10.1109/jqe.1974.1068351

Related papers

Millimeter wave radiation detectors of Josephson junctions.

Hiroshi Ohta

•Jan 1, 1982•1 citation

Chapter 6 The Josephson Junction as a Detector of Microwave and Far-Infrared Radiation

P. L. Richards

Semiconductors and semimetals•Jan 1, 1977•21 citations

Josephson junction millimeter microwave source and homodyne detector

B. T. Ulrich, E.O. Kluth

A millimeter and submillimeter microwave source is described in which a point-contact Josephson junction is used as both the emitter and as a homodyne detector of the microwave radiation. The microwave radiation is conveyed from the Josephson junction to the room-temperature environment outside the Dewar of liquid helium by an oversize waveguide. A room-temperature Fabry-Perot resonator refocuses the radiation on the oversize waveguide which returns the radiation to the emitting junction which also serves as a coherent detector with sensitivity 10-15W/√Hz. The detector is sufficiently sensitive that the emitted power of 10-12W can be detected with high signal-to-noise ratio. Power required by the junction is of the order 10-6W from the bias supply. For the experiments reported, the wavelength of the emission could be varied over discrete wavelengths between 1.1 and 2.6 mm by varying the voltage bias across the junction. These wavelengths corresponded to the resonant frequencies of a cavity tightly coupled to the Josephson junction, and the frequencies can be changed by modifying the geometry of the cavity.

Proceedings of the IEEE•Jan 1, 1973•18 citations

The Josephson junction as a detector of microwave and far infrared radiation

P. L. Richards

This document was prepared as an account of

Unknown eBooks•Jun 1, 1969•8 citations

Radiation power and linewidth of a semifluxon-based Josephson oscillator

M. Paramonov, M. Yu. Fominsky, V. P. Koshelets +4 more

We demonstrate a high-frequency generator operating at ∼200 GHz based on flipping a semifluxon in a Josephson junction of moderate normalized length. The semifluxon spontaneously appears at the π discontinuity of the Josephson phase artificially created by means of two tiny current injectors. The radiation is detected by an on-chip detector (tunnel junction). The estimated radiation power (at the detector) is ∼8 nW and should be compared with the dc power of ∼100 nW consumed by the generator. The measured radiation linewidth, as low as 1.1 MHz, is typical for geometrical (Fiske) resonances, although we tried to suppress such resonances by placing well-matched microwave transformers at its both ends. Making use of a phase-locking feedback loop, we are able to reduce the radiation linewidth to less than 1 Hz measured relative to the reference oscillator and defined just by the resolution of our measurement setup.

arXiv:1311.5922•Applied Physics Letters•Feb 10, 2014•2 citations

“Non-Josephson” radiation from Josephson tunnel junctions

D. N. Langenberg, William H. Parker, Barry N. Taylor

Physics Letters•Aug 1, 1966•12 citations
A millimeter and submillimeter microwave source is described in which a point-contact Josephson junction is used as both the emitter and as a homodyne detector of the microwave radiation. The microwave radiation is conveyed from the Josephson junction to the room-temperature environment outside the Dewar of liquid helium by an oversize waveguide. A room-temperature Fabry-Perot resonator refocuses the radiation on the oversize waveguide which returns the radiation to the emitting junction which also serves as a coherent detector with sensitivity 10-15W/√Hz. The detector is sufficiently sensitive that the emitted power of 10-12W can be detected with high signal-to-noise ratio. Power required by the junction is of the order 10-6W from the bias supply. For the experiments reported, the wavelength of the emission could be varied over discrete wavelengths between 1.1 and 2.6 mm by varying the voltage bias across the junction. These wavelengths corresponded to the resonant frequencies of a cavity tightly coupled to the Josephson junction, and the frequencies can be changed by modifying the geometry of the cavity.
We demonstrate a high-frequency generator operating at ∼200 GHz based on flipping a semifluxon in a Josephson junction of moderate normalized length. The semifluxon spontaneously appears at the π discontinuity of the Josephson phase artificially created by means of two tiny current injectors. The radiation is detected by an on-chip detector (tunnel junction). The estimated radiation power (at the detector) is ∼8 nW and should be compared with the dc power of ∼100 nW consumed by the generator. The measured radiation linewidth, as low as 1.1 MHz, is typical for geometrical (Fiske) resonances, although we tried to suppress such resonances by placing well-matched microwave transformers at its both ends. Making use of a phase-locking feedback loop, we are able to reduce the radiation linewidth to less than 1 Hz measured relative to the reference oscillator and defined just by the resolution of our measurement setup.