Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Novel superconducting thermometer for bolometric applications

D. G. McDonald

Published Mar 23, 1987• 72 citations
Publisher

Abstract

The temperature dependence of the magnetic penetration depth in a superconductor, in the kinetic inductance limit, is proposed as a basis for a sensitive thermometer. Considered as a bolometer, the noise equivalent power from the sum of the Johnson noise and the preamplifier noise can be reduced to about 7×10−20 W/(Hz)1/2, which is approximately four orders of magnitude below currently realized values.

DOI
10.1063/1.98042

Related papers

Superconducting kinetic inductance bolometer

Joseph E. Sauvageau, Donald G. McDonald

The authors are developing a bolometer with a temperature sensor based on the temperature dependence of the inductance of a superconducting microstrip line. As a first step in exploring this idea experimentally, they have designed experiments to test only the temperature sensor. The experimental devices are all-niobium inductance thermometers fabricated on silicon substrates which have been deeply etched to provide areas of relative thermal isolation. The ground plane superconductor is thin enough so that its kinetic inductance dominates the audio frequency impedance of the stripline near its critical temperature, at 0.9 T/sub c/. This differential thermometer uses a commercial SQUID (superconducting quantum interference device) as the preamplifier. Preliminary results demonstrate a proof-of-principle for the thermometer design. An important quality factor for this type of measurement system is the depth of the null. The authors achieved a high value of 0.4*10/sup -6/, which is satisfying for a first try.>

IEEE Transactions on Magnetics•Mar 1, 1989•26 citations

Model of superconducting alternating current bolometers

M. A. Lindeman, P. Khosropanah, R. A. Hijmering

We present a model of the response of superconducting AC bolometers to signal and noise using parameters and matrix formalism that were previously adopted in modeling DC bolometers and microcalorimeters. The model was developed to investigate novel AC bolometer designs, which have properties not described by previous models. It is applicable to kinetic inductance devices, kinetic inductance thermometers, AC transition edge sensors, and other technologies based on AC read out and frequency mixing. The AC bolometer model includes the temperature and current dependence of both resistive and inductive bolometers and microcalorimeters. The bolometers may be thermal or athermal. The model compactly describes the complex relationships between electrical and thermal signals and it simplifies the associated calculations. This model is useful for characterizing bolometers, predicting the effects of various noise sources on performance and designing new detectors. Additionally, a measurement technique is developed for characterizing these devices.

Journal of Applied Physics•Feb 15, 2013•10 citations

Far-infrared kinetic-inductance detectors

Erich N. Grossman, Donald G. McDonald, Joseph E. Sauvageau

Extremely sensitive far-infrared detectors suitable for both direct detection and heterodyne applications, based on mu m-sized thin films with thickness less than a superconducting penetration depth are possible. The penetration depth of such a film, and therefore its inductance, varies with temperature and with quasiparticle population (described by an effective temperature T*), resulting in both bolometric and nonequilibrium photoinductive responses. Incident radiation is coupled into the small-area kinetic inductor by a lithographic antenna, and the resulting inductance changes are amplified and converted to a voltage signal by an integrated microstrip DC SQUID. The device is sensitive because, unlike junction-based devices with large capacitive reactances, the kinetic inductor is naturally well matched to the antenna impedance at the far-IR frequency ( nu >2 Delta /h) and to the preamplifier (SQUID) impedance at microwave or video frequencies ( nu <<2 Delta /h). The best kinetic inductor materials are those with low electronic mean free path, large penetration depth, and high critical current density. Thus, common magnet alloys such as NbTi are the natural choice for liquid-He temperature operation. A detailed analysis predicts a (phonon-limited) NEP of 4*10/sup -17/ W/ square root Hz for a bolometer with an iridium kinetic inductor operated at 0.1 K. A heterodyne noise temperature of 2250 K (single-sideband) at 3 THz, with a 200-MHz bandwidth, is predicted for a Nb-Ti mixer operated at 4 K.

IEEE Transactions on Magnetics•Mar 1, 1991•39 citations

Ultrasensitive hot-electron kinetic-inductance detectors

A. Sergeev, Boris S. Karasik, I. G. Gogidze +1 more

While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.

AIP conference proceedings•Jan 1, 2002•3 citations

Cryogenic Thermometry Based on Superconducting Microwave Resonators

André Chatel

Cryogenic systems are essential to many modern scientific and technological applications, including MRI superconducting magnets, particle accelerators, astrophysical detectors and quantum computing platforms, all of which operate at temperatures well below 120 K. In this framework, accurate temperature monitoring is, therefore, critical. However, conventional Resistance Temperature Detectors (RTDs) suffer from significant limitations in cryogenic environments, such as wiring complexity, power dissipation, limited low-temperature operation and large footprint, which restrict their integration in increasingly complex cryogenic infrastructures. Superconducting devices offer a promising alternative due to their high sensitivity at low temperatures, low power dissipation and compatibility with integrated quantum technologies. Inspired by Microwave Kinetic Inductance Detectors (MKIDs), this work investigates superconducting microwave resonators as minimally invasive, frequency-multiplexed cryogenic thermometers operating below 12 K. In particular, strategies to tune and enhance temperature sensitivity are explored by studying the effects of the superconducting thin-film thickness and surface nanostructuring. The first part of the study examines NbTi(N) planar resonators with thicknesses ranging from 20 nm to 150 nm, where temperature sensing is based on the temperature dependence of the kinetic inductance. S-shaped split-ring resonators resonating near 1.1 GHz are inductively coupled to a coplanar transmission line and characterized under cryogenic conditions. A clear trade-off between temperature sensitivity and quality factor is observed: thinner films achieve higher sensitivity, up to approximately 19 MHz/K for 20 nm thick devices, while the quality factor, typically exceeding 10^4, is found to degrade when the thickness is reduced. This trade-off leads to an optimal temperature resolution, with sub-microkelvin noise-equivalent temperature (NET) values. In particular, a minimum NET of (0.53±0.09) µK/Hz^(1/2) at 4.2 K is achieved for a 100 nm thick resonator, which is also exploited to study low-frequency temperature fluctuations in liquid helium. In the second part, a possible approach to enhance the temperature sensitivity, through surface nanostructuring, is investigated. Arrays of nanogaps are patterned in high-current regions of a 1.3 GHz resonator, in order to locally suppress superconductivity, reduce the critical temperature of the film and, therefore, accentuate the slope of the temperature-sensitive curve. These weak-links are realized by partially etching a 100 nm NbTi film, to leave 20-30 nm thick remaining nanogaps. Measurements reveal a significant increase in temperature sensitivity, reaching values as high as up to (62±1) MHz/K, which correspond to one order-of-magnitude improvement over non-nanostructured devices. Although this enhancement comes with increased noise-equivalent temperature, the results demonstrate the feasibility of engineering superconducting weak links to improve RF cryogenic thermometry and provide a solid foundation for future optimization. In reason of the achieved results, such an approach could find successful applications for a sub-µK high-resolution cryogenic temperature monitoring, specifically for integrated quantum architectures, further benefiting from the frequency-multiplexing that naturally arises from the multiple allocation of different superconducting microwave resonators.

•Jan 1, 2026•0 citations

A superconducting bolometer with strong electrothermal feedback

Adrian Tae-Jin Lee, Paul L. Richards, Sae Woo Nam +2 more

We present a theoretical analysis and experimental evaluation of a transition-edge superconducting bolometer for detecting infrared and millimeter waves. The superconducting film is voltage biased and the current is read by a superconducting quantum interference device ammeter. Strong electrothermal feedback maintains the sensor temperature within the transition, gives a current responsivity that is simply the inverse of the bias voltage, and reduces the response time by several orders of magnitude below the intrinsic time constant C/G. We evaluated a voltage-biased bolometer that operates on the Tc∼95 mK transition of a tungsten film with a thermal conductance of G∼1.2×10−9 W/K. As expected, the electrical noise equivalent power of 3.3×10−17/W√Hz is close to the thermal fluctuation noise limit and is lower than that of other technologies for these values of G and temperature. The measured time constant of 10 μs is ∼100 times faster than the intrinsic time constant.

Applied Physics Letters•Sep 16, 1996•200 citations
The temperature dependence of the magnetic penetration depth in a superconductor, in the kinetic inductance limit, is proposed as a basis for a sensitive thermometer. Considered as a bolometer, the noise equivalent power from the sum of the Johnson noise and the preamplifier noise can be reduced to about 7×10−20 W/(Hz)1/2, which is approximately four orders of magnitude below currently realized values.
The authors are developing a bolometer with a temperature sensor based on the temperature dependence of the inductance of a superconducting microstrip line. As a first step in exploring this idea experimentally, they have designed experiments to test only the temperature sensor. The experimental devices are all-niobium inductance thermometers fabricated on silicon substrates which have been deeply etched to provide areas of relative thermal isolation. The ground plane superconductor is thin enough so that its kinetic inductance dominates the audio frequency impedance of the stripline near its critical temperature, at 0.9 T/sub c/. This differential thermometer uses a commercial SQUID (superconducting quantum interference device) as the preamplifier. Preliminary results demonstrate a proof-of-principle for the thermometer design. An important quality factor for this type of measurement system is the depth of the null. The authors achieved a high value of 0.4*10/sup -6/, which is satisfying for a first try.>
We present a model of the response of superconducting AC bolometers to signal and noise using parameters and matrix formalism that were previously adopted in modeling DC bolometers and microcalorimeters. The model was developed to investigate novel AC bolometer designs, which have properties not described by previous models. It is applicable to kinetic inductance devices, kinetic inductance thermometers, AC transition edge sensors, and other technologies based on AC read out and frequency mixing. The AC bolometer model includes the temperature and current dependence of both resistive and inductive bolometers and microcalorimeters. The bolometers may be thermal or athermal. The model compactly describes the complex relationships between electrical and thermal signals and it simplifies the associated calculations. This model is useful for characterizing bolometers, predicting the effects of various noise sources on performance and designing new detectors. Additionally, a measurement technique is developed for characterizing these devices.
Extremely sensitive far-infrared detectors suitable for both direct detection and heterodyne applications, based on mu m-sized thin films with thickness less than a superconducting penetration depth are possible. The penetration depth of such a film, and therefore its inductance, varies with temperature and with quasiparticle population (described by an effective temperature T*), resulting in both bolometric and nonequilibrium photoinductive responses. Incident radiation is coupled into the small-area kinetic inductor by a lithographic antenna, and the resulting inductance changes are amplified and converted to a voltage signal by an integrated microstrip DC SQUID. The device is sensitive because, unlike junction-based devices with large capacitive reactances, the kinetic inductor is naturally well matched to the antenna impedance at the far-IR frequency ( nu >2 Delta /h) and to the preamplifier (SQUID) impedance at microwave or video frequencies ( nu <<2 Delta /h). The best kinetic inductor materials are those with low electronic mean free path, large penetration depth, and high critical current density. Thus, common magnet alloys such as NbTi are the natural choice for liquid-He temperature operation. A detailed analysis predicts a (phonon-limited) NEP of 4*10/sup -17/ W/ square root Hz for a bolometer with an iridium kinetic inductor operated at 0.1 K. A heterodyne noise temperature of 2250 K (single-sideband) at 3 THz, with a 200-MHz bandwidth, is predicted for a Nb-Ti mixer operated at 4 K.
While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.
Cryogenic systems are essential to many modern scientific and technological applications, including MRI superconducting magnets, particle accelerators, astrophysical detectors and quantum computing platforms, all of which operate at temperatures well below 120 K. In this framework, accurate temperature monitoring is, therefore, critical. However, conventional Resistance Temperature Detectors (RTDs) suffer from significant limitations in cryogenic environments, such as wiring complexity, power dissipation, limited low-temperature operation and large footprint, which restrict their integration in increasingly complex cryogenic infrastructures. Superconducting devices offer a promising alternative due to their high sensitivity at low temperatures, low power dissipation and compatibility with integrated quantum technologies. Inspired by Microwave Kinetic Inductance Detectors (MKIDs), this work investigates superconducting microwave resonators as minimally invasive, frequency-multiplexed cryogenic thermometers operating below 12 K. In particular, strategies to tune and enhance temperature sensitivity are explored by studying the effects of the superconducting thin-film thickness and surface nanostructuring. The first part of the study examines NbTi(N) planar resonators with thicknesses ranging from 20 nm to 150 nm, where temperature sensing is based on the temperature dependence of the kinetic inductance. S-shaped split-ring resonators resonating near 1.1 GHz are inductively coupled to a coplanar transmission line and characterized under cryogenic conditions. A clear trade-off between temperature sensitivity and quality factor is observed: thinner films achieve higher sensitivity, up to approximately 19 MHz/K for 20 nm thick devices, while the quality factor, typically exceeding 10^4, is found to degrade when the thickness is reduced. This trade-off leads to an optimal temperature resolution, with sub-microkelvin noise-equivalent temperature (NET) values. In particular, a minimum NET of (0.53±0.09) µK/Hz^(1/2) at 4.2 K is achieved for a 100 nm thick resonator, which is also exploited to study low-frequency temperature fluctuations in liquid helium. In the second part, a possible approach to enhance the temperature sensitivity, through surface nanostructuring, is investigated. Arrays of nanogaps are patterned in high-current regions of a 1.3 GHz resonator, in order to locally suppress superconductivity, reduce the critical temperature of the film and, therefore, accentuate the slope of the temperature-sensitive curve. These weak-links are realized by partially etching a 100 nm NbTi film, to leave 20-30 nm thick remaining nanogaps. Measurements reveal a significant increase in temperature sensitivity, reaching values as high as up to (62±1) MHz/K, which correspond to one order-of-magnitude improvement over non-nanostructured devices. Although this enhancement comes with increased noise-equivalent temperature, the results demonstrate the feasibility of engineering superconducting weak links to improve RF cryogenic thermometry and provide a solid foundation for future optimization. In reason of the achieved results, such an approach could find successful applications for a sub-µK high-resolution cryogenic temperature monitoring, specifically for integrated quantum architectures, further benefiting from the frequency-multiplexing that naturally arises from the multiple allocation of different superconducting microwave resonators.
We present a theoretical analysis and experimental evaluation of a transition-edge superconducting bolometer for detecting infrared and millimeter waves. The superconducting film is voltage biased and the current is read by a superconducting quantum interference device ammeter. Strong electrothermal feedback maintains the sensor temperature within the transition, gives a current responsivity that is simply the inverse of the bias voltage, and reduces the response time by several orders of magnitude below the intrinsic time constant C/G. We evaluated a voltage-biased bolometer that operates on the Tc∼95 mK transition of a tungsten film with a thermal conductance of G∼1.2×10−9 W/K. As expected, the electrical noise equivalent power of 3.3×10−17/W√Hz is close to the thermal fluctuation noise limit and is lower than that of other technologies for these values of G and temperature. The measured time constant of 10 μs is ∼100 times faster than the intrinsic time constant.