Revue de Physique Appliquée

Superconducting tunnel junction bolometers

John L. Clarke, G. I. Hoffer, P. L. Richards

Published Jan 1, 1974• 31 citations
Publisher

Abstract

Two new types of superconducting infrared bolometer are described. In one, the temperature dependent Josephson current in an SNS junction is measured with a SQUID galvanometer. In the other, the temperature-dependent quasiparticle tunneling current in an SIN junction is measured with a conventional fet amplifier. Either type of junction is deposited on a low heat capacity sapphire substrate covered on the reverse side with a thin Bi film to absorb infrared radiation. The best performance achieved thus far is for the SNS bolometer which has an electrical NEP ~ 5 x 10 -15 W/√Hz and D* ~ 1014 cm. W-1. Hz1/2. Some improvement in these values is anticipated.

DOI
10.1051/rphysap:019740090106900

Related papers

Superconductive bolometers for submillimeter wavelengths

John L. Clarke, G. I. Hoffer, P. L. Richards +1 more

Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.

Journal of Applied Physics•Dec 1, 1977•142 citations

Superconducting Bolometers: High-Tc and low-Tc

P L Richards

A description is given of recent work at Berkeley on superconducting detectors and mixers for infrared and millimeter wavelengths. The first report is a review article which summarizes the status of development of superconducting components for infrared and millimeter wave receivers. Next, a report is given on measurements and theoretical modeling of the absorptivity (surface resistance) of high quality epitaxial films of the high-Tc superconductor YBCO from 750 GHz to 21 THz. The next report describes measurements of the thermal boundary resistance between YBCO films and various substrates. This resistance is much larger than expected from the acoustic impedance mismatch model and gives a thermal time constant in the nanosecond range for typical YBCO films. Then, there are reports on the design and experimental performance of two different types of high-Tc bolometric detectors. One is a conventional bolometer with a gold-black absorber. The other is an antenna coupled microbolometer. The properties of a low-Tc microbolometer are also described. The last reports describe accurate measurements and also theoretical modeling of an SIS quasiparticle waveguide mixer for W-band which uses very high quality Ta junctions. The best mixer noise is only 1.3 times the quantum limit. Both the mixer gain and the noise are in quantitative agreement with the quantum theory.

•Jul 22, 2024•0 citations

Superconducting thermo-electric bolometer for cosmology instruments

L. S. Kuzmin

A novel type of the zero-biased thermo-electric bolometer (TEB) is proposed. The bolometer is based on a Charge-to-Voltage Converter (CVC) with a Superconductor- Insulator-Normal (SIN) Tunnel Junction and a superconducting absorber. The absorption of photons in the absorber leads to excitation of quasiparticles with some fraction of charge imbalance, tunneling through the SIN junction and generation of voltage. The thermoelectric voltage is determined by accumulation of tunneling charge in an external capacitance. Conversion efficiency is very high and voltage values comparable with a superconducting gap are easily achieved. The zero-biased CVC-TEB can be effectively used for creation of an array of bolometers.

•Mar 1, 2010•0 citations

Capacitively Coupled Hot-Electron Nanobolometer with SIN Tunnel Junctions

L. S. Kuzmin, M. Yu. Fominsky, Alexei Kalabukhov +2 more

A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 1, 2003•6 citations

Optimal Cold-Electron Bolometer with a Superconductor-Insulator-Normal Tunnel Junction and an Andreev Contact

L. S. Kuzmin

A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.

•May 1, 2006•3 citations

Superconducting bolometers: high-Tc and low-Tc

Paul L. Richards

A description is given of recent work at Berkeley on superconducting detectors and mixers for infrared and millimeter wavelengths. The first report is a review article which summarizes the status of development of superconducting components for infrared and millimeter wave receivers. Next, a report is given on measurements and theoretical modeling of the absorptivity (surface resistance) of high quality epitaxial films of the high-Tc superconductor YBCO from 750 GHz to 21 THz. The next report describes measurements of the thermal boundary resistance between YBCO films and various substrates. This resistance is much larger than expected from the acoustic impedance mismatch model and gives a thermal time constant in the nanosecond range for typical YBCO films. Reports are also included on the design and experimental performance of two different types of high-Tc bolometric detectors. One is a conventional bolometer with a gold-black absorber. The other is an antenna coupled microbolometer. The properties of a low-Tc microbolometer are also described. The last reports describe accurate measurements and also theoretical modeling of an SIS quasi-particle waveguide mixer for W-band which uses very high quality Ta junctions. The best mixer noise is only 1.3 times the quantum limit. Both the mixer gain and the noise are in quantitative agreement with the quantum theory.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 1, 1991•3 citations
Two new types of superconducting infrared bolometer are described. In one, the temperature dependent Josephson current in an SNS junction is measured with a SQUID galvanometer. In the other, the temperature-dependent quasiparticle tunneling current in an SIN junction is measured with a conventional fet amplifier. Either type of junction is deposited on a low heat capacity sapphire substrate covered on the reverse side with a thin Bi film to absorb infrared radiation. The best performance achieved thus far is for the SNS bolometer which has an electrical NEP ~ 5 x 10 -15 W/√Hz and D* ~ 1014 cm. W-1. Hz1/2. Some improvement in these values is anticipated.
Three types of composite superconductive bolometers are described in which the temperature-sensitive element is a superconducting film at the transition temperature, a superconductor–normal metal–superconductor Josephson junction, or a superconductor–insulator–normal metal quasiparticle tunneling junction. The temperature-sensitive element is evaporated onto a sapphire substrate on the reverse side of which is a bismuth film to absorb the submillimeter radiation. The noise limitations of each type of bolometer are calculated. The fabrication and measured performance of the transition-edge bolometer and the Josephson-junction bolometer are described. The best electrical (noise-equivalent power) NEP obtained with a transition-edge bolometer fabricated on a 4×4×0.005-mm sapphire substrate is (1.7±0.1) ×10−15 W Hz−1/2 at 2 Hz at an operating temperature of 1.27 K. This NEP is within a factor of 2 of the thermal noise limit. The effective absorptivity of the bismuth film is measured to be 0.47±0.05, and the corresponding detectivity D* is calculated to be (1.1±0.1) ×1014 cm W−1 Hz1/2. Suggestions are made for further improvements in sensitivity.
A description is given of recent work at Berkeley on superconducting detectors and mixers for infrared and millimeter wavelengths. The first report is a review article which summarizes the status of development of superconducting components for infrared and millimeter wave receivers. Next, a report is given on measurements and theoretical modeling of the absorptivity (surface resistance) of high quality epitaxial films of the high-Tc superconductor YBCO from 750 GHz to 21 THz. The next report describes measurements of the thermal boundary resistance between YBCO films and various substrates. This resistance is much larger than expected from the acoustic impedance mismatch model and gives a thermal time constant in the nanosecond range for typical YBCO films. Then, there are reports on the design and experimental performance of two different types of high-Tc bolometric detectors. One is a conventional bolometer with a gold-black absorber. The other is an antenna coupled microbolometer. The properties of a low-Tc microbolometer are also described. The last reports describe accurate measurements and also theoretical modeling of an SIS quasiparticle waveguide mixer for W-band which uses very high quality Ta junctions. The best mixer noise is only 1.3 times the quantum limit. Both the mixer gain and the noise are in quantitative agreement with the quantum theory.
A novel type of the zero-biased thermo-electric bolometer (TEB) is proposed. The bolometer is based on a Charge-to-Voltage Converter (CVC) with a Superconductor- Insulator-Normal (SIN) Tunnel Junction and a superconducting absorber. The absorption of photons in the absorber leads to excitation of quasiparticles with some fraction of charge imbalance, tunneling through the SIN junction and generation of voltage. The thermoelectric voltage is determined by accumulation of tunneling charge in an external capacitance. Conversion efficiency is very high and voltage values comparable with a superconducting gap are easily achieved. The zero-biased CVC-TEB can be effectively used for creation of an array of bolometers.
A capacitively coupled hot-electron nanobolometer (CC-HEB) is the simplest and most effective antenna-coupled bolometer. The bolometer consists of a small absorber connected to the superconducting antenna by tunnel junctions. The tunnel junctions used for high-frequency coupling also give perfect thermal isolation of hot electrons in the small volume of the absorber. The same tunnel junctions are used for temperature measurements and electron cooling. This bolometer does not suffer from the frequency limitations in the submillimeter range due to the high potential barrier of the tunnel junctions as does the microbolometer with Andreev mirrors (A-HEB), which is limited by the superconducting gap. Theoretical analyses show that the two-junction configuration more than doubles the sensitivity of the bolometer in current-biased mode compared to the single-junction configuration used for A-HEB. Another important advantage of CC-HEB is its simple two-layer technology for sample fabrication. Samples were fabricated with an absorber made of a bilayer of Cr and Al to match the impedance of the antenna. Electrodes were made of Al and tunnel junctions were formed over the Al oxide layer. The coupling capacitances of the tunnel junctions, C ≈ 20 fF, in combination with the inductance of the 10 μm absorber create a bandpass filter with a central frequency around 300 GHz. Bolometers are integrated with log-periodic and double-dipole planar antennas made of Au. The temperature response of bolometer structures was measured at temperatures down to 256 mK. In our experiment we observed dV/dT=1.3 mV/K, corresponding to responsivity S=0.2.109 V/W. For amplifier noise Vna=3nV/Hz1/2 at 1 kHz the estimated total noise equivalent power is NEP=1.5.10-17 W/Hz1/2. The intrinsic bolometer self noise Vnbol=0.5 nV/Hz1/2 corresponds to NEP=3.10-18 W/Hz1/2. For microwave evaluation of bolometer sensitivity we used a black body radiation source comprising a thin NiCr stimulator placed on the cold plate of cryostat in front of a CC-HEB attached to an extended hemisphere sapphire lens. This measurements were consistent with estimates based on the dc responsivity of the bolometer.
A novel concept of the optimal Cold-Electron Bolometer (CEB) with a Superconductor-Insulator-Normal (SIN) Tunnel Junction and Andreev SN contact has been proposed. This concept has been developed to improve noise properties of the CEB by increasing current responsivity for SQUID readout (in voltage-biased mode) in comparison with classical CEB concept comprising two SIN tunnel junctions. In this configuration the power of incoming signal is not split between two series junctions and the current response of a single junction is twice larger in comparison with double junction structure. The signal is concentrated from antenna to an absorber through capacitance of the tunnel junction from one side and Andreev contact from another side. HF matching is realized by resistance of a normal metal absorber that is independent on tunnel junction parameters. The volume of a normal metal is partly squeezed due to proximity effect of a superconducting electrode from the Andreev contact that also increases efficiency of the electron cooling. The concept is based on direct electron cooling of the absorber by SIN tunnel junction that serves as negative electrothermal feedback for the signal. Noise properties are considerably improved by decreasing the electron temperature. Ultimate performance of the CEB is determined by optical load converted to shot noise of the signal readout. The goal is to achieve noise-equivalent power (NEP) of the CEB with standard SQUID readout less than photon noise. Ultimate NEP better than photon noise can be achieved practically in wide range of power loads from 0.1 fW (SPICA) to 30 pW (OLIMPO, CLOVER, PILOT). Applicability of the CEB to post-Herschel space missions looks very promising.
A description is given of recent work at Berkeley on superconducting detectors and mixers for infrared and millimeter wavelengths. The first report is a review article which summarizes the status of development of superconducting components for infrared and millimeter wave receivers. Next, a report is given on measurements and theoretical modeling of the absorptivity (surface resistance) of high quality epitaxial films of the high-Tc superconductor YBCO from 750 GHz to 21 THz. The next report describes measurements of the thermal boundary resistance between YBCO films and various substrates. This resistance is much larger than expected from the acoustic impedance mismatch model and gives a thermal time constant in the nanosecond range for typical YBCO films. Reports are also included on the design and experimental performance of two different types of high-Tc bolometric detectors. One is a conventional bolometer with a gold-black absorber. The other is an antenna coupled microbolometer. The properties of a low-Tc microbolometer are also described. The last reports describe accurate measurements and also theoretical modeling of an SIS quasi-particle waveguide mixer for W-band which uses very high quality Ta junctions. The best mixer noise is only 1.3 times the quantum limit. Both the mixer gain and the noise are in quantitative agreement with the quantum theory.