Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics A

Trapped ion density distribution in the presence of He-buffer gas

H. W. Schaaf, U. Schmeling, Günther Werth

Published Jul 1, 1981• 105 citations
Publisher
DOI
10.1007/bf00902978

Related papers

Buffer gas cooling of a trapped ion to the quantum regime

Michał Tomza, Thomas Feldker, Henning A. Fürst +5 more

Bulletin of the American Physical Society•Jun 5, 2020•0 citations

Buffer gas cooling of a trapped ion to the quantum regime

Thomas Feldker, Henning A. Fürst, Henrik Hirzler +5 more

arXiv:1907.10926•Nature Physics•Feb 3, 2020•91 citations

Simulations for Ion Traps Buffer Gas Cooling

S. Schwarz

Lecture notes in physics•Jan 1, 2008•11 citations

Determination of Characteristics of Yb+ Ion Cloud Trapped in a RF Trap with He Buffer Gas

潤 依田, 和彦 杉山

計量研究所報告•Jan 1, 1993•0 citations

Determination of Characteristics of Yb+ Ion Cloud Trapped in a RF Trap with He Buffer Gas

Jun Yoda, Kazuhiko Sugiyama

Characteristics of the Yb+ ion cloud trapped in a rf trap in the presence of He buffer gas were determined by fluorescence detection as well as the rf resonance method. Combining the results obtained by the two methods, we determined the spatial ion density distribution and found that the trapped ions were thermalized by collisions with the He buffer gas. It was confirmed by both methods that the harmonic motion of the trapped ions was excited by the trapping field leaked to the rf resonance detection circuit (subharmonic oscillation), and moreover, by the fluorescence detection method, that the probing rf field used for the rf resonance method was indispensable as “the initial push” for exciting the amplitude.

Japanese Journal of Applied Physics•Nov 1, 1992•2 citations

The energy distribution of an ion in a radiofrequency trap interacting with a nonuniform neutral buffer gas

Ian Rouse, Stefan Willitsch

An ion in a radiofrequency (rf) trap sympathetically cooled by a simultaneously trapped neutral buffer gas exhibits deviations from thermal statistics caused by collision-induced coupling of the rf field to the ion motion. For a uniform density distribution of the buffer gas, the energy distribution of the ion can be described by Tsallis statistics. Moreover, runaway heating of the ion occurs if the buffer gas particles are sufficiently heavy relative to the ion. In typical experiments, however, ultracold buffer gases are confined in traps resulting in localised, non-uniform density distributions. Using a superstatistical approach, we develop an analytical model for an ion interacting with a localised buffer gas. We demonstrate theoretically that limiting collisions to the centre of the ion trap enables cooling at far greater mass ratios than achievable using a uniform buffer gas, but that an upper limit to the usable mass ratio exists even in this case. Furthermore, we analytically derive the functional form of the energy distribution for an ion interacting with a buffer gas held in a harmonic potential. The analytical distribution obtained is found to be in excellent agreement with the results of numerical simulations.

arXiv:1811.12134•Molecular Physics•Mar 14, 2019•3 citations
Characteristics of the Yb+ ion cloud trapped in a rf trap in the presence of He buffer gas were determined by fluorescence detection as well as the rf resonance method. Combining the results obtained by the two methods, we determined the spatial ion density distribution and found that the trapped ions were thermalized by collisions with the He buffer gas. It was confirmed by both methods that the harmonic motion of the trapped ions was excited by the trapping field leaked to the rf resonance detection circuit (subharmonic oscillation), and moreover, by the fluorescence detection method, that the probing rf field used for the rf resonance method was indispensable as “the initial push” for exciting the amplitude.
An ion in a radiofrequency (rf) trap sympathetically cooled by a simultaneously trapped neutral buffer gas exhibits deviations from thermal statistics caused by collision-induced coupling of the rf field to the ion motion. For a uniform density distribution of the buffer gas, the energy distribution of the ion can be described by Tsallis statistics. Moreover, runaway heating of the ion occurs if the buffer gas particles are sufficiently heavy relative to the ion. In typical experiments, however, ultracold buffer gases are confined in traps resulting in localised, non-uniform density distributions. Using a superstatistical approach, we develop an analytical model for an ion interacting with a localised buffer gas. We demonstrate theoretically that limiting collisions to the centre of the ion trap enables cooling at far greater mass ratios than achievable using a uniform buffer gas, but that an upper limit to the usable mass ratio exists even in this case. Furthermore, we analytically derive the functional form of the energy distribution for an ion interacting with a buffer gas held in a harmonic potential. The analytical distribution obtained is found to be in excellent agreement with the results of numerical simulations.