Quantum Information Processing

Variations on the theme of quantum optical coherence tomography: a review

Malvin Carl Teich, Bahaa E. A. Saleh, Franco N. C. Wong, Jeffrey H. Shapiro

Published Aug 2, 2011• 51 citations
Publisher
DOI
10.1007/s11128-011-0266-6

Related papers

Polarization-sensitive optical coherence tomography: a review of classical and quantum perspectives

Renu Tripathi

Quantum Information Processing•Oct 11, 2011•3 citations

Spectral-domain optical coherence tomography based on nonlinear interferometers

Arturo Rojas-Santana, Gerard J. Machado, Maria V. Chekhova +2 more

Optical coherence tomography (OCT) is a 3D imaging technique that was introduced in 1991 [Science 254, 1178 (1991); Applied Optics 31, 919 (1992)]. Since 2018 there has been growing interest in a new type of OCT scheme based on the use of so-called nonlinear interferometers, interferometers that contain optical parametric amplifiers. Some of these OCT schemes are based on the idea of induced coherence [Physical Review A 97, 023824 (2018)], while others make use of an SU(1,1) interferometer [Quantum Science and Technology 3 025008 (2018)]. What are the differences and similarities between the output signals measured in standard OCT and in these new OCT schemes? Are there any differences between OCT schemes based on induced coherence and on an SU(1,1) interferometer? Differences can unveil potential advantages of OCT based on nonlinear interferometers when compared with conventional OCT schemes. Similarities might benefit the schemes based on nonlinear interferometers from the wealth of research and technology related to conventional OCT schemes. In all cases we will consider the scheme where the optical sectioning of the sample is obtained by measuring the output signal spectrum (spectral, or Fourier-domain OCT), since it shows better performance in terms of speed and sensitivity than its counterpart time-domain OCT.

arXiv:2108.05998•Aug 12, 2021•0 citations

Quantum optical coherence tomography

Magued B. Nasr

•Jan 1, 2005•0 citations

Quantum optical coherence tomography of a biological sample

Magued B. Nasr, Darryl P. Goode, Nam Nguyen +5 more

arXiv:0809.4721•Optics Communications•Dec 10, 2008•85 citations

Polarization-sensitive quantum optical coherence tomography: Experiment

Mark C. Booth, Bahaa E. A. Saleh, Malvin Carl Teich

arXiv:1011.4338•Optics Communications•Feb 15, 2011•22 citations

Theoretical framework for real time sub-micron depth monitoring using quantum inline coherent imaging

Alexander A. C. Wainwright, Khaled Madhoun

Inline Coherent Imaging (ICI) is a reliable method for real-time monitoring of various laser processes, including keyhole welding, additive manufacturing, and micromachining. However, the axial resolution is limited to greater than 2 μm making ICI unsuitable for monitoring submicron processes. Advancements in Quantum Optical Coherence Tomography (QOCT), which uses a Hong-Ou-Mandel (HOM) interferometer, has the potential to address this issue by achieving better than 1 μm depth resolution. While time-resolved QOCT is slow, Fourier domain QOCT (FD-QOCT) overcomes this limitation, enabling submicron scale real-time process monitoring. Here we review the fundamentals of FD-QOCT and QOCT and propose a Quantum Inline Coherent Imaging system based on FD-QOCT. Using frequency entangled sources available today the system has a theoretical resolution of 0.17 microns, making it suitable for submicron real-time process monitoring.

arXiv:2309.09325•Sep 17, 2023•0 citations
Optical coherence tomography (OCT) is a 3D imaging technique that was introduced in 1991 [Science 254, 1178 (1991); Applied Optics 31, 919 (1992)]. Since 2018 there has been growing interest in a new type of OCT scheme based on the use of so-called nonlinear interferometers, interferometers that contain optical parametric amplifiers. Some of these OCT schemes are based on the idea of induced coherence [Physical Review A 97, 023824 (2018)], while others make use of an SU(1,1) interferometer [Quantum Science and Technology 3 025008 (2018)]. What are the differences and similarities between the output signals measured in standard OCT and in these new OCT schemes? Are there any differences between OCT schemes based on induced coherence and on an SU(1,1) interferometer? Differences can unveil potential advantages of OCT based on nonlinear interferometers when compared with conventional OCT schemes. Similarities might benefit the schemes based on nonlinear interferometers from the wealth of research and technology related to conventional OCT schemes. In all cases we will consider the scheme where the optical sectioning of the sample is obtained by measuring the output signal spectrum (spectral, or Fourier-domain OCT), since it shows better performance in terms of speed and sensitivity than its counterpart time-domain OCT.
Inline Coherent Imaging (ICI) is a reliable method for real-time monitoring of various laser processes, including keyhole welding, additive manufacturing, and micromachining. However, the axial resolution is limited to greater than 2 μm making ICI unsuitable for monitoring submicron processes. Advancements in Quantum Optical Coherence Tomography (QOCT), which uses a Hong-Ou-Mandel (HOM) interferometer, has the potential to address this issue by achieving better than 1 μm depth resolution. While time-resolved QOCT is slow, Fourier domain QOCT (FD-QOCT) overcomes this limitation, enabling submicron scale real-time process monitoring. Here we review the fundamentals of FD-QOCT and QOCT and propose a Quantum Inline Coherent Imaging system based on FD-QOCT. Using frequency entangled sources available today the system has a theoretical resolution of 0.17 microns, making it suitable for submicron real-time process monitoring.