Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

One-atom maser: Statistics of detector clicks

Hans‐Jürgen Briegel, Berthold‐Georg Englert, Nicoletta Sterpi, HERBERT WALTHER

Published Apr 1, 1994• 87 citations
Publisher

Abstract

We present a general theory for the calculation of various characteristic properties of the beam of atoms emerging from a resonator in one-atom-maser experiments. The beam is described in terms of the statistics of the detector clicks. The evolution of the state of the maser photons between clicks is governed by a nonlinear master equation. The nonlinearity originates in the necessity to account for the atoms that escape detection. Despite the permanent reductions of the photon state, resulting from the detections, the steady state of the conventional linear master equation determines the statistics of the detector clicks. The whole process is ergodic, in the sense that a single run of the experiment contains all reproducible statistical data, provided the duration of the run is much longer than all relevant correlation times. The nonlinear master equation is used to calculate the distribution of waiting times between detector clicks. Other statistical properties of the clicks that are derived include correlation functions and variances of the counting statistics. The formalism is applied to standard one-atom-maser experiments and to parity measurements on both unpumped and pumped cavities. We find that, for the standard one-atom-maser operation, none of the said statistical properties is a simple immediate indicator for a sub-Poissonian variance of the photon number. For example, the detector clicks may be antibunched although the photon distribution has a super-Poissonian variance.

DOI
10.1103/physreva.49.2962

Related papers

One-atom maser: Phase-sensitive measurements

Berthold‐Georg Englert, Tserensodnom Gantsog, Axel Schenzle +2 more

We reconsider a variant of the one-atom-maser setup in which the emerging atoms are probed for coherent superpositions of the two Rydberg states of the maser transition. The statistical properties of the corresponding detector clicks contain information about the temporal evolution of the phase of the quantized electromagnetic field inside the resonator. We derive analytical expressions for certain statistical quantities, such as the mean number of successive clicks of the same kind, or the atom-atom and the photon-photon correlation functions. The latter are closely related if the photon-number distribution in steady state is dominated by a single narrow peak. \textcopyright{} 1996 The American Physical Society.

Physical Review A•Jun 1, 1996•30 citations

Detection statistics in the micromaser

David B. Johnson, William C. Schieve

We present a general method for the derivation of various statistical quantities describing the detection of a beam of atoms emerging from a micromaser. The use of non-normalized conditioned density operators and a linear master equation for the dynamics between detection events is discussed as are the counting statistics, sequence statistics, and waiting time statistics. In particular, we derive expressions for the mean number of successive detections of atoms in one of any two orthogonal states of the two-level atom. We also derive expressions for the mean waiting times between detections. We show that the mean waiting times between detections of atoms in like states are equivalent to the mean waiting times calculated from the uncorrelated steady state detection rates, although like atoms are indeed correlated. The mean waiting times between detections of atoms in unlike states exhibit correlations. We evaluate the expressions for various detector efficiencies using numerical integration, reporting results for the standard micromaser arrangement in which the cavity is pumped by excited atoms and the excitation levels of the emerging atoms are measured. In addition, the atomic inversion and the Fano-Mandel function for the detection of deexcited atoms are calculated for comparison to the experimental results of Weidinger et al. [Phys. Rev. Lett. 82, 3795 (1999)], who report the observation of trapping states.

arXiv:quant-ph/0008082•Physical Review A•Feb 9, 2001•7 citations

Theory of detection in the micromaser

Rebecca R. McGowan, William C. Schieve

The field in the micromaser cavity, the atoms which both pump and probe the micromaser, and the detectors that determine the outgoing states of the atoms are treated as a single system in order to derive a nonlinear master equation for the field in the micromaser cavity which takes the effect of undetected atoms into account. Analytic solutions for this master equation are found for both phase-insensitive and phase-sensitive detection. These solutions can be used to explicitly show the back-action effects that measurement has on the spectrum of the micromaser. In addition, these solutions are used to find analytic expressions for the mean number of successive detector clicks of the same kind as well as atom-atom and photon-photon correlation functions. In this way, the analytic solutions are linked to experimentally accessible data.

Physical Review A•Jan 1, 1999•6 citations

One-atom maser with a periodic and noisy pump: An application of damping bases

Hans‐Jürgen Briegel, Berthold‐Georg Englert, Christian Ginzel +1 more

We study the one-atom maser with a periodic-pump scheme for the injected atoms. The dynamics of the system is solved also in a regime where the losses of the field cannot be neglected while the atom is inside the cavity, as is the situation in an optical maser. The time development of the maser field is described by a general evolution operator, whose matrix representation in the damping basis is known analytically for zero temperature. The numerical evaluation of this matrix yields the stationary as well as the transient properties of the maser. Noise-producing mechanisms of the pump are included explicitly in the evolution operator for the field. These are a finite efficiency of the pump laser, a velocity spread in the atomic beam, and spontaneous transitions between the atomic levels and to the ground state. We find that features such as trapped states and sub-Poissonian photon statistics also occur in the high-loss regime like in an optical resonator. The observation of such effects will, as in the ordinary micromaser experiments, depend very sensitively on the reduction of the pump noise. For highly regular excitation, we find a pronounced oscillation of the field-correlation function for a wide range of the transit time, which leads to a distinct line splitting in the spectrum of the field. The amount of the splitting is determined by the periodicity of the pump. For less regular excitation, and in particular in the Poissonian limit, these oscillations disappear.

Physical Review A•Jun 1, 1994•29 citations

Micromaser with stationary non-Poissonian pumping

Ulrike Herzog

A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.

Physical Review A•Jul 1, 1995•22 citations

Elements of Micromaser Physics

Berthold‐Georg Englert

The elements of micromaser physics are reviewed in a tutorial way. The emphasis is on the basic theoretical concepts, not on technical details or experimental subtleties. After a brief treatment of the atom-photon interaction according to the Jaynes-Cummings model, the master equation that governs the dynamics of the one-atom maser is derived. Then the more important properties of the steady states of the one-atom maser are discussed, including the trapped states. The approximations, upon which the standard theoretical model of the one-atom maser is based, are exhibited. The methods by which one calculates statistical properties of the emerging atoms are hinted at.

arXiv:quant-ph/0203052•Mar 13, 2002•15 citations
We present a general theory for the calculation of various characteristic properties of the beam of atoms emerging from a resonator in one-atom-maser experiments. The beam is described in terms of the statistics of the detector clicks. The evolution of the state of the maser photons between clicks is governed by a nonlinear master equation. The nonlinearity originates in the necessity to account for the atoms that escape detection. Despite the permanent reductions of the photon state, resulting from the detections, the steady state of the conventional linear master equation determines the statistics of the detector clicks. The whole process is ergodic, in the sense that a single run of the experiment contains all reproducible statistical data, provided the duration of the run is much longer than all relevant correlation times. The nonlinear master equation is used to calculate the distribution of waiting times between detector clicks. Other statistical properties of the clicks that are derived include correlation functions and variances of the counting statistics. The formalism is applied to standard one-atom-maser experiments and to parity measurements on both unpumped and pumped cavities. We find that, for the standard one-atom-maser operation, none of the said statistical properties is a simple immediate indicator for a sub-Poissonian variance of the photon number. For example, the detector clicks may be antibunched although the photon distribution has a super-Poissonian variance.
We reconsider a variant of the one-atom-maser setup in which the emerging atoms are probed for coherent superpositions of the two Rydberg states of the maser transition. The statistical properties of the corresponding detector clicks contain information about the temporal evolution of the phase of the quantized electromagnetic field inside the resonator. We derive analytical expressions for certain statistical quantities, such as the mean number of successive clicks of the same kind, or the atom-atom and the photon-photon correlation functions. The latter are closely related if the photon-number distribution in steady state is dominated by a single narrow peak. \textcopyright{} 1996 The American Physical Society.
We present a general method for the derivation of various statistical quantities describing the detection of a beam of atoms emerging from a micromaser. The use of non-normalized conditioned density operators and a linear master equation for the dynamics between detection events is discussed as are the counting statistics, sequence statistics, and waiting time statistics. In particular, we derive expressions for the mean number of successive detections of atoms in one of any two orthogonal states of the two-level atom. We also derive expressions for the mean waiting times between detections. We show that the mean waiting times between detections of atoms in like states are equivalent to the mean waiting times calculated from the uncorrelated steady state detection rates, although like atoms are indeed correlated. The mean waiting times between detections of atoms in unlike states exhibit correlations. We evaluate the expressions for various detector efficiencies using numerical integration, reporting results for the standard micromaser arrangement in which the cavity is pumped by excited atoms and the excitation levels of the emerging atoms are measured. In addition, the atomic inversion and the Fano-Mandel function for the detection of deexcited atoms are calculated for comparison to the experimental results of Weidinger et al. [Phys. Rev. Lett. 82, 3795 (1999)], who report the observation of trapping states.
The field in the micromaser cavity, the atoms which both pump and probe the micromaser, and the detectors that determine the outgoing states of the atoms are treated as a single system in order to derive a nonlinear master equation for the field in the micromaser cavity which takes the effect of undetected atoms into account. Analytic solutions for this master equation are found for both phase-insensitive and phase-sensitive detection. These solutions can be used to explicitly show the back-action effects that measurement has on the spectrum of the micromaser. In addition, these solutions are used to find analytic expressions for the mean number of successive detector clicks of the same kind as well as atom-atom and photon-photon correlation functions. In this way, the analytic solutions are linked to experimentally accessible data.
We study the one-atom maser with a periodic-pump scheme for the injected atoms. The dynamics of the system is solved also in a regime where the losses of the field cannot be neglected while the atom is inside the cavity, as is the situation in an optical maser. The time development of the maser field is described by a general evolution operator, whose matrix representation in the damping basis is known analytically for zero temperature. The numerical evaluation of this matrix yields the stationary as well as the transient properties of the maser. Noise-producing mechanisms of the pump are included explicitly in the evolution operator for the field. These are a finite efficiency of the pump laser, a velocity spread in the atomic beam, and spontaneous transitions between the atomic levels and to the ground state. We find that features such as trapped states and sub-Poissonian photon statistics also occur in the high-loss regime like in an optical resonator. The observation of such effects will, as in the ordinary micromaser experiments, depend very sensitively on the reduction of the pump noise. For highly regular excitation, we find a pronounced oscillation of the field-correlation function for a wide range of the transit time, which leads to a distinct line splitting in the spectrum of the field. The amount of the splitting is determined by the periodicity of the pump. For less regular excitation, and in particular in the Poissonian limit, these oscillations disappear.
A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.
The elements of micromaser physics are reviewed in a tutorial way. The emphasis is on the basic theoretical concepts, not on technical details or experimental subtleties. After a brief treatment of the atom-photon interaction according to the Jaynes-Cummings model, the master equation that governs the dynamics of the one-atom maser is derived. Then the more important properties of the steady states of the one-atom maser are discussed, including the trapped states. The approximations, upon which the standard theoretical model of the one-atom maser is based, are exhibited. The methods by which one calculates statistical properties of the emerging atoms are hinted at.