Japanese Journal of Applied Physics

30-km-long optical fiber link at 1397 nm for frequency comparison between distant strontium optical lattice clocks

Tomoya Akatsuka, Hitomi Ono, Keitaro Hayashida, Kuniya Araki, Masao Takamoto, T. Takano, Hidetoshi Katori

Published Feb 5, 2014• 30 citations
Publisher

Abstract

We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at RIKEN and the University of Tokyo. We use a transfer laser at 1397 nm, which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1 × 10−17 for an averaging time of τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with a stability of 1 × 10−17(τ/s)−1/2 by synchronously operating two distant clocks.

DOI
10.7567/jjap.53.032801

Related papers

A 30-km-long optical fiber link for frequency comparison between distant strontium optical lattice clocks

Tomoya Akatsuka, Hitomi Ono, Keitaro Hayashida +4 more

We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at Riken and the University of Tokyo. We use a transfer laser at 1397 nm which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1×1017for an averaging time τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with stability of 10 (τ/s) by synchronously operating the two distant clocks.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•1 citation

Remote Comparison of Two Sr Optical Lattice Clocks through a 58 km Fiber Link

Tang-Yin 堂银 Liao 廖, Hao 豪 Liu 刘, Fei Meng +9 more

Abstract Two 87Sr optical lattice clocks (OLCs) are being developed and operated at the National Institute of Metrology (NIM), located on different campuses that are 40 km apart. In order to compare the optical frequencies of these two Sr OLCs, a 58-km noise canceled fiber link is built to transfer both a 1542-nm transfer laser and a microwave reference from Changping campus to Hepingli campus. Two commercial optical frequency combs (OFCs) with adapted single-branch 698/1542 nm outputs coherently unite the two 698-nm clock lasers and the 1542-nm transfer laser. The fractional instability of the comparison yields 3.1 × 10−17 at 10000 s averaging time. The measured fractional frequency difference between these two Sr OLCs was evaluated to be 1.9(3.2) × 10−17, which is within their claimed uncertainties. This result demonstrates the consistency of their frequencies when they serve as optical frequency standards. Our remote comparison demonstrates the feasibility of optical clock comparison through a long-distance fiber link and contributes to the progress of redefinition of the SI second.

Chinese Physics Letters•Feb 17, 2025•3 citations

All-optical link for direct comparison of distant optical clocks

Miho Fujieda, Motohiro Kumagai, Shigeo Nagano +3 more

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

arXiv:1108.2775•Optics Express•Aug 11, 2011•93 citations

Measuring the frequency of a Sr optical lattice clock using a 120 km coherent optical transfer

Feng-Lei Hong, M. Musha, Masao Takamoto +11 more

We demonstrate a precision frequency measurement using a phase-stabilized 120 km optical fiber link over a physical distance of 50 km. The transition frequency of the (87)Sr optical lattice clock at the University of Tokyo is measured to be 429228004229874.1(2.4) Hz referenced to international atomic time. The results demonstrate the excellent functions of the intercity optical fiber link and the great potential of optical lattice clocks for use in the redefinition of the second.

arXiv:0811.1816•Optics Letters•Feb 25, 2009•113 citations

A clock network for geodesy and fundamental science

Christian Lisdat, Gesine Grosche, Nicolas Quintin +32 more

Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

arXiv:1511.07735•Nature Communications•Aug 9, 2016•460 citations

Optical direct comparison of87Sr optical lattice clocks using a >50 km telecommunication fiber link

Hidekazu Hachisu, Atsushi Yamaguchi, Miho Fujieda +7 more

An 87Sr-based-optical lattice clock in NICT is compared to that of The University of Tokyo using a >50 km fiber link. In this work, we have demonstrated for the first time that two distant Sr lattice clocks generate the same frequency with systematic uncertainty of 0.31 Hz (7.3 × 10-16 fractionally) for the 429 THz clock frequency.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 8, 2011•1 citation
We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at RIKEN and the University of Tokyo. We use a transfer laser at 1397 nm, which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1 × 10−17 for an averaging time of τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with a stability of 1 × 10−17(τ/s)−1/2 by synchronously operating two distant clocks.
We demonstrate a 30-km-long optical fiber link for frequency comparison between two strontium optical lattice clocks being developed at Riken and the University of Tokyo. We use a transfer laser at 1397 nm which is twice the wavelength of the clock transition of strontium clocks. The link stability is estimated to be 1×1017for an averaging time τ = 1 s, which is in good agreement with the theoretical limit calculated from the fiber noise spectrum. We discuss a remote clock comparison with stability of 10 (τ/s) by synchronously operating the two distant clocks.
Abstract Two 87Sr optical lattice clocks (OLCs) are being developed and operated at the National Institute of Metrology (NIM), located on different campuses that are 40 km apart. In order to compare the optical frequencies of these two Sr OLCs, a 58-km noise canceled fiber link is built to transfer both a 1542-nm transfer laser and a microwave reference from Changping campus to Hepingli campus. Two commercial optical frequency combs (OFCs) with adapted single-branch 698/1542 nm outputs coherently unite the two 698-nm clock lasers and the 1542-nm transfer laser. The fractional instability of the comparison yields 3.1 × 10−17 at 10000 s averaging time. The measured fractional frequency difference between these two Sr OLCs was evaluated to be 1.9(3.2) × 10−17, which is within their claimed uncertainties. This result demonstrates the consistency of their frequencies when they serve as optical frequency standards. Our remote comparison demonstrates the feasibility of optical clock comparison through a long-distance fiber link and contributes to the progress of redefinition of the SI second.
We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.
Leveraging the unrivalled performance of optical clocks as key tools for geo-science, for astronomy and for fundamental physics beyond the standard model requires comparing the frequency of distant optical clocks faithfully. Here, we report on the comparison and agreement of two strontium optical clocks at an uncertainty of 5 × 10(-17) via a newly established phase-coherent frequency link connecting Paris and Braunschweig using 1,415 km of telecom fibre. The remote comparison is limited only by the instability and uncertainty of the strontium lattice clocks themselves, with negligible contributions from the optical frequency transfer. A fractional precision of 3 × 10(-17) is reached after only 1,000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than any previous long-distance clock comparison. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.