Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

International Journal of Quantum Information

DEVELOPMENT OF SUPERCONDUCTING SINGLE-PHOTON DETECTORS AT I.N.Ri.M.

E. Taralli, M. Rajteri, E. Monticone, Chiara Portesi

Published Feb 1, 2007• 5 citations
Publisher

Abstract

We are developing single-photon detectors employing superconducting-transition-edge sensors (TESs). TESs are fabricated both with Ti and proximity bilayers of Ti / Au and the characterisitcs of the two films are compared. In the visible-near infrared spectral region, the photon absorption occurs directly in the film and the quantum efficiency of the detector is limited by the reflection losses at the film surface, which are around 60%. For many applications, like quantum cryptography, these losses are too high. In a previous paper [Nucl. Instr. Meth. A559(2) (2006) 757–759], we presented a way to reduce the detector reflectance for two projects based on the deposition of a few layers of amorphous silicon-nitrogen alloys. In this paper, we report some experimental data at low temperature relative to those projects. We will also show how to minimize the detector reflectance simultaneously for three telecommunication wavelengths and for a new continuum band.

DOI
10.1142/s0219749907002761

Related papers

Development of Titanium-Based Transition-Edge Single-Photon Detector

Wen Zhang, Yue Geng, Zheng Wang +7 more

Superconducting transition-edge sensors (TESs), working as single-photon detectors with high quantum efficiency, low dark count rate, and photon number resolving capability, have been successfully used in quantum information experiments as well as astronomical transient object observations. Aiming to achieve high count rate, we are developing titanium-based superconducting TES single-photon detectors with a critical temperature of ~300 mK. Ti-based TESs with active area from 10 × 10 μm to 40 × 40 μm are first fabricated on silicon substrate coated with SiOx. The fabricated TES devices show a thermal conductance scaling with the active area and an effective time constant of ~4 μs from pulsed laser diode illumination. In order to get high quantum efficiency, we further design and fabricate a 1550-nm optical cavity based on dielectric mirror and antireflection layer, and study its absorption with an IR spectrometer. Ti TES devices on the dielectric mirror are then fabricated and the superconducting transition is measured.

IEEE Transactions on Applied Superconductivity•Mar 19, 2019•19 citations

Development of High Detection Efficiency Titanium Transition-Edge Sensors for 1550 nm Single-Photon Detection

Xiaolong Xu, Peizhan Li, Carlo Pepe +10 more

Transition-edge sensors (TESs) have shown the capability of both energy resolution and resolving photon numbers. In this work, we present the fabrication and characterization of high detection efficiency Ti optical TESs with the critical temperatureTc= 213 mK and the photon-number resolving capability at telecommunication wavelength 1550 nm. The Ti superconducting film is prepared by a DC magnetron sputtering technique. An optical cavity comprised of 5-layers antireflection and 15-layers high-reflection Ta2O5/SiO2is enclosed with the Ti film by an ion beam assisted deposition method to improve detection efficiency, which brings the absorption of 99.74%. The energy resolution for the Ti TES with sensitive area 20 μm × 20 μm is 0.45 eV and the detection efficiency is 97% ± 1%.

IEEE Transactions on Applied Superconductivity•Jan 12, 2026•2 citations

Superconducting transition-edge sensors optimized for high-efficiency photon-number resolving detectors

Adriana E. Lita, Brice Calkins, Lenson A. Pellouchoud +2 more

Superconducting photon detectors have emerged as a powerful new option for detecting single photons. System detection efficiency that incorporates the quantum efficiency of the device and system losses is one of the most important single-photon detector performance metrics for quantum information applications. Superconducting transition-edge sensors (TESs) are microcalorimeters that have the ability of distinguishing single photons with negligible dark counts. In addition, TESs are capable of directly measuring the photon number in a pulse of light. We have achieved near-unity system detection efficiency with TESs at particular wavelengths in the near-infrared by using multilayer structures that enhance the absorption of light into the active device material. We describe the design of the multilayer structure enabling high detection efficiency TESs including issues and requirements for obtaining detection efficiency values higher than 99 %. We describe the device fabrication and finally, show recent results of devices optimized for high detection efficiency using the multilayer structure.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 20, 2010•51 citations

Counting near-infrared single-photons with 95% efficiency

Adriana E. Lita, Aaron Miller, Sae Woo Nam

Single-photon detectors operating at visible and near-infrared wavelengths with high detection efficiency and low noise are a requirement for many quantum-information applications. Superconducting transition-edge sensors (TESs) are capable of detecting visible and near-infrared light at the single-photon level and are capable of discriminating between one- and two-photon absorption events; however these capabilities place stringent design requirements on the TES heat capacity, thermometry, and optical detection efficiency. We describe the fabrication and evaluation of a fiber-coupled, photon-number-resolving TES detector optimized for absorption at 1550 and 1310 nm wavelengths. The measured system detection efficiency at 1556 nm is 95 % +/- 2 %, which to our knowledge is the highest system detection efficiency reported for a near-infrared single-photon detector.

Optics Express•Jan 1, 2008•733 citations

Photon-Number Resolving by Superconductive Devices

L. Lolli

Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths

•Jan 1, 2012•0 citations

Investigation of Ti/Pd Bilayer for Single Photon Detection

E. Taralli, Chiara Portesi, Roberto Rocci +2 more

Transition-edge sensor (TES) microcalorimeters are promising for application in the field of quantum information and quantum computation thanks to their outstanding single photon detection capabilities. Good energy resolution and photon number discrimination at visible and near-infrared wavelengths make them extensively used as single photon detectors. In this work we report details on the fabrication of Pd/Ti TESs deposited by e-beam evaporation on silicon nitride substrates. We use Pd as alternative to Au layer thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. The transition temperatures Tcof the devices range from 83 to 110 mK with a transition width DeltaTc=0.5 mK. Thermal and electric characteristics of Pd/Ti TESs at different temperatures and its capability as single photon sensor are reported.

IEEE Transactions on Applied Superconductivity•Jun 1, 2009•16 citations
We are developing single-photon detectors employing superconducting-transition-edge sensors (TESs). TESs are fabricated both with Ti and proximity bilayers of Ti / Au and the characterisitcs of the two films are compared. In the visible-near infrared spectral region, the photon absorption occurs directly in the film and the quantum efficiency of the detector is limited by the reflection losses at the film surface, which are around 60%. For many applications, like quantum cryptography, these losses are too high. In a previous paper [Nucl. Instr. Meth. A559(2) (2006) 757–759], we presented a way to reduce the detector reflectance for two projects based on the deposition of a few layers of amorphous silicon-nitrogen alloys. In this paper, we report some experimental data at low temperature relative to those projects. We will also show how to minimize the detector reflectance simultaneously for three telecommunication wavelengths and for a new continuum band.
Superconducting transition-edge sensors (TESs), working as single-photon detectors with high quantum efficiency, low dark count rate, and photon number resolving capability, have been successfully used in quantum information experiments as well as astronomical transient object observations. Aiming to achieve high count rate, we are developing titanium-based superconducting TES single-photon detectors with a critical temperature of ~300 mK. Ti-based TESs with active area from 10 × 10 μm to 40 × 40 μm are first fabricated on silicon substrate coated with SiOx. The fabricated TES devices show a thermal conductance scaling with the active area and an effective time constant of ~4 μs from pulsed laser diode illumination. In order to get high quantum efficiency, we further design and fabricate a 1550-nm optical cavity based on dielectric mirror and antireflection layer, and study its absorption with an IR spectrometer. Ti TES devices on the dielectric mirror are then fabricated and the superconducting transition is measured.
Transition-edge sensors (TESs) have shown the capability of both energy resolution and resolving photon numbers. In this work, we present the fabrication and characterization of high detection efficiency Ti optical TESs with the critical temperatureTc= 213 mK and the photon-number resolving capability at telecommunication wavelength 1550 nm. The Ti superconducting film is prepared by a DC magnetron sputtering technique. An optical cavity comprised of 5-layers antireflection and 15-layers high-reflection Ta2O5/SiO2is enclosed with the Ti film by an ion beam assisted deposition method to improve detection efficiency, which brings the absorption of 99.74%. The energy resolution for the Ti TES with sensitive area 20 μm × 20 μm is 0.45 eV and the detection efficiency is 97% ± 1%.
Superconducting photon detectors have emerged as a powerful new option for detecting single photons. System detection efficiency that incorporates the quantum efficiency of the device and system losses is one of the most important single-photon detector performance metrics for quantum information applications. Superconducting transition-edge sensors (TESs) are microcalorimeters that have the ability of distinguishing single photons with negligible dark counts. In addition, TESs are capable of directly measuring the photon number in a pulse of light. We have achieved near-unity system detection efficiency with TESs at particular wavelengths in the near-infrared by using multilayer structures that enhance the absorption of light into the active device material. We describe the design of the multilayer structure enabling high detection efficiency TESs including issues and requirements for obtaining detection efficiency values higher than 99 %. We describe the device fabrication and finally, show recent results of devices optimized for high detection efficiency using the multilayer structure.
Single-photon detectors operating at visible and near-infrared wavelengths with high detection efficiency and low noise are a requirement for many quantum-information applications. Superconducting transition-edge sensors (TESs) are capable of detecting visible and near-infrared light at the single-photon level and are capable of discriminating between one- and two-photon absorption events; however these capabilities place stringent design requirements on the TES heat capacity, thermometry, and optical detection efficiency. We describe the fabrication and evaluation of a fiber-coupled, photon-number-resolving TES detector optimized for absorption at 1550 and 1310 nm wavelengths. The measured system detection efficiency at 1556 nm is 95 % +/- 2 %, which to our knowledge is the highest system detection efficiency reported for a near-infrared single-photon detector.
Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths
Transition-edge sensor (TES) microcalorimeters are promising for application in the field of quantum information and quantum computation thanks to their outstanding single photon detection capabilities. Good energy resolution and photon number discrimination at visible and near-infrared wavelengths make them extensively used as single photon detectors. In this work we report details on the fabrication of Pd/Ti TESs deposited by e-beam evaporation on silicon nitride substrates. We use Pd as alternative to Au layer thanks to its stronger influence on the Ti layer, that allows to obtain the same temperature reduction with thinner layers. The transition temperatures Tcof the devices range from 83 to 110 mK with a transition width DeltaTc=0.5 mK. Thermal and electric characteristics of Pd/Ti TESs at different temperatures and its capability as single photon sensor are reported.