Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Micromaser and separated-oscillatory-field measurements

Robert J. Brecha, Achim Peters, Christian Wagner, HERBERT WALTHER

Published Jul 1, 1992• 30 citations
Publisher

Abstract

The connection between proposed experiments involving a micromaser and the Ramsey technique of separated oscillatory fields is explored, specifically with regard to possible experiments to measure the phase-diffusion linewidth of the maser. A method of detecting the trapping states and a setup to identify the two-level system as being a true spin-1/2 system are presented. In addition, a pictorial view of the time evolution of the atomic Bloch vector is given.

DOI
10.1103/physreva.46.567

Related papers

Phase diffusion, entangled states, and quantum measurements in the micromaser

Christian Wagner, Robert J. Brecha, Axel Schenzle +1 more

In this paper we show how different measurement schemes for a micromaser system may be used to investigate different aspects of the maser dynamics. The features which are investigated include a measurement of the phase diffusion in steady-state, transient states with several orders of coherence, and an interesting connection to questions of the Einstein-Podolsky-Rosen paradox. In addition, it is shown rigorously that different measurement schemes acting only on the atomic part of the system after the cavity have no influence on the ensemble properties of the cavity field.

Physical Review A•Jun 1, 1993•47 citations

Experiments with the One-atom-maser

Linas Urbonas

There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.

•Jan 1, 2009•0 citations

Micromaser spectrum

Marlan O. Scully, HERBERT WALTHER, G. S. Agarwal +2 more

We calculate the spectrum of the micromaser for a wide range of pump parameters and propose a multiple microwave field method similar to the Ramsey fringe technique to measure this spectrum. Thus it becomes possible to investigate the phase diffusion in a fundamental system such as the micromaser.

Physical Review A•Nov 1, 1991•98 citations

Micromaser spectrum and phase diffusion dynamics

Federico Casagrande, Alessandro Ferraro, ALFREDO LULLI +3 more

We discuss a scheme to relate the phase diffusion dynamics of the micromaser field to the measured atomic population statistics. This can allow us to measure the linewidth of the micromaser spectrum and to solve a relevant decoherence problem in cavity quantum electrodynamics. The main steps are (i) a suitable preparation of the cavity field state to generate coherences, (ii) the transfer of information on the dynamics of field coherences to probe atoms by the action of an external resonant coherent field and (iii) the derivation of the phase diffusion rate, hence the micromaser linewidth, from the measured population statistics of the probe atoms. The method can be applied even in the presence of trapping states, where peculiar linewidth oscillations are expected for increasing pump rate, due to the quantum nature of the micromaser field.

Journal of Optics B Quantum and Semiclassical Optics•Aug 1, 2003•3 citations

How to measure the micromaser spectrum in the trapping state regime

Federico Casagrande, Alessandro Ferraro, ALFREDO LULLI +3 more

We show how our recently proposed scheme for the measurement of the micromaser linewidth, which relates the phase diffusion dynamics of the cavity field to the population statistics of probe atoms, can be applied in the presence of trapping states, where the phase diffusion approximation does not strictly hold. This should allow the observation of the peculiar linewidth oscillations versus atomic pumping which are expected in this regime, and whose origin lies in the quantum nature of the cavity field.

Journal of Modern Optics•Apr 1, 2004•0 citations

How to Measure the Phase Diffusion Dynamics in the Micromaser

Federico Casagrande, Alessandro Ferraro, ALFREDO LULLI +3 more

We propose a realistic scheme for measuring the micromaser linewidth by monitoring the phase diffusion dynamics of the cavity field. Our strategy consists of exciting an initial coherent state with the same photon number distribution as the micromaser steady-state field, singling out a purely diffusive process in the system dynamics. After the injection of a counterfield, measurements of the population statistics of a probe atom allow us to derive the micromaser linewidth in all ranges of the relevant parameters, establishing experimentally the distinctive features of the micromaser spectrum due to the discreteness of the electromagnetic field.

arXiv:quant-ph/0208027•Physical Review Letters•May 5, 2003•20 citations
The connection between proposed experiments involving a micromaser and the Ramsey technique of separated oscillatory fields is explored, specifically with regard to possible experiments to measure the phase-diffusion linewidth of the maser. A method of detecting the trapping states and a setup to identify the two-level system as being a true spin-1/2 system are presented. In addition, a pictorial view of the time evolution of the atomic Bloch vector is given.
In this paper we show how different measurement schemes for a micromaser system may be used to investigate different aspects of the maser dynamics. The features which are investigated include a measurement of the phase diffusion in steady-state, transient states with several orders of coherence, and an interesting connection to questions of the Einstein-Podolsky-Rosen paradox. In addition, it is shown rigorously that different measurement schemes acting only on the atomic part of the system after the cavity have no influence on the ensemble properties of the cavity field.
There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.
We discuss a scheme to relate the phase diffusion dynamics of the micromaser field to the measured atomic population statistics. This can allow us to measure the linewidth of the micromaser spectrum and to solve a relevant decoherence problem in cavity quantum electrodynamics. The main steps are (i) a suitable preparation of the cavity field state to generate coherences, (ii) the transfer of information on the dynamics of field coherences to probe atoms by the action of an external resonant coherent field and (iii) the derivation of the phase diffusion rate, hence the micromaser linewidth, from the measured population statistics of the probe atoms. The method can be applied even in the presence of trapping states, where peculiar linewidth oscillations are expected for increasing pump rate, due to the quantum nature of the micromaser field.
We show how our recently proposed scheme for the measurement of the micromaser linewidth, which relates the phase diffusion dynamics of the cavity field to the population statistics of probe atoms, can be applied in the presence of trapping states, where the phase diffusion approximation does not strictly hold. This should allow the observation of the peculiar linewidth oscillations versus atomic pumping which are expected in this regime, and whose origin lies in the quantum nature of the cavity field.
We propose a realistic scheme for measuring the micromaser linewidth by monitoring the phase diffusion dynamics of the cavity field. Our strategy consists of exciting an initial coherent state with the same photon number distribution as the micromaser steady-state field, singling out a purely diffusive process in the system dynamics. After the injection of a counterfield, measurements of the population statistics of a probe atom allow us to derive the micromaser linewidth in all ranges of the relevant parameters, establishing experimentally the distinctive features of the micromaser spectrum due to the discreteness of the electromagnetic field.