Physical Review A
Parametric amplification and squeezing of a mode-locked pulse train: A comparison of MgO:LiNbO3 with bulk periodically poled LiNbO3
E. M. Daly, A. I. Ferguson
Abstract
We report on an initial squeezing of 3.3 dB below the shot noise level, generated in bulk, quasi-phase-matched lithium niobate. This squeezing was generated by degenerate parametric amplification, at 1047 nm, of a mode-locked pulse train. We present a detailed comparison of the process performed in both the quasi-phase-matched material and in ${\mathrm{M}\mathrm{g}\mathrm{O}:\mathrm{L}\mathrm{i}\mathrm{N}\mathrm{b}\mathrm{O}}_{3},$ which was phase matched using conventional birefringent methods. The single-pass gain measured was 2.5 from ${\mathrm{M}\mathrm{g}\mathrm{O}:\mathrm{L}\mathrm{i}\mathrm{N}\mathrm{b}\mathrm{O}}_{3}$ and 3.9 from periodically poled lithium niobate (PPLN), although the former was affected by photorefractive damage. We directly recorded $11%$ of noise reduction in the vacuum using the PPLN parametric amplifier, purely because the detection efficiency was so low in our experiment. The experimental data was fitted to a model which includes the initial squeezing level and the homodyne detector efficiency as free parameters. The observed squeezing agrees well with the a total detection efficiency of just $16%$ and an initial squeezing level of 3.3 dB (53%) in PPLN.