Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Background limited superconducting quantum detector for submillimeter astronomy

Alexei D. Semenov, Andreas Engel, Heinz‐Wilhelm Hübers, Konstantin Il ́in, M. Siegel

Published Feb 1, 2003• 1 citation
Publisher

Abstract

We extend the concept of the superconducting quantum counter in order to develop a new quantum detector for submillimeter astronomy. The detector exploits a cumulative detection mechanism, in which the response appears due to successive formation of the normal spot and a resistive domain in a narrow strip carrying sub-critical supercurrent. The intrinsic recovery time of the counter is partly determined by diffusion of nonequilibrium electrons and, thus, depends on the energy of detected photons. Depending on the superconducting material used and operation conditions, such detector may have cut-off wavelengths for the single-photon regime ranging from terahertz waves to visible light and simultaneously provide a moderate energy resolution. We simulated performance of the background-limited submillimeter direct detector from Ti having the 100-micrometer cut-off wavelength, low dark count rate and intrinsic 10-21 W Hz-1/2 noise equivalent power for 4-K background radiation. We present first results obtained with a detector prototype fabricated from ultra-thin Nb film.

DOI
10.1117/12.459180

Related papers

Ultimate performance of a superconducting quantum detector

Alexei D. Semenov, Andreas Engel, K. Ilin +3 more

We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.

The European Physical Journal Applied Physics•Feb 27, 2003•48 citations

Spectral response of an infrared superconducting quantum detector

Alexei D. Semenov, Andreas Engel, Heinz‐Wilhelm Hübers +2 more

We analyze the spectral performance of recently developed single-photon quantum detector that consists of a narrow, nanometer sized meander-line made from ultra-thin superconducting film. The detector exploits a combined detection mechanism, in which avalanche multiplication of quasiparticles after absorption of a single photon and the bias current jointly produce a normal domain that results in a voltage pulse developing between the meander ends. With either the wavelength increase or the bias current decrease, the single-photon detection regime exhibits a cut-off. The wavelength, at which the cut-off occurs, varies from infrared waves to visible light depending on the superconducting material and operation conditions. Structural and geometrical non-uniformities of the meander line smooth out the otherwise expected sharp drop of the detection efficiency beyond the cut-off. We refine the early detector model and propose a tentative explanation of how superconducting fluctuations may additionally extend the detection efficiency beyond the cut-off wavelength.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 1, 2004•5 citations

A concept for a submillimeter-wave single-photon counter

R. J. Schoelkopf, S. H. Moseley, Carl M. Stahle +2 more

We discuss the design for a submillimeter-wave photometer, using a combination of superconducting and single-electron devices, which would have high quantum efficiency, very low noise-equivalent powers, and eventually even submicrosecond timing resolution. The absorption of above-gap photons occurs in a small strip of superconducting Al, whose normal-state resistance can be matched efficiently to an antenna of a higher gap (Nb) superconductor. The quasiparticles produced by photon absorption are then confined via Andreev reflection, and forced to tunnel through a small SIS tunnel junction. The tunneling time is much shorter than the known (>10 /spl mu/s) quasiparticle recombination time, so collection efficiency will be high. The device sensitivity would be limited by the small subgap current in the high-quality Al/AlO/sub x//Al tunnel junction at temperatures (100 mK) well below T/sub c/. Scaling based on the larger junctions used in X-ray detector applications suggests that the total dark current can be <0.1 pA, or of order 10/sup 5/ electrons/second, corresponding to an NEP of less than 10/sup -19/ W//spl radic/Hz at 500 microns (600 GHz). The photocurrent will be measured using a fast single-electron transistor (RF-SET), which allows a shot-noise-limited performance even for the very small currents delivered from this low capacitance and high impedance SIS junction. Results of initial fabrication and dc characterization of an integrated photodetector are also given.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•69 citations

Superconducting nanostructured detectors capable of single photon counting of mid-infrared optical radiation

I. Milostnaya, Alexander A. Korneev, Olga V. Minaeva +13 more

We report on our progress in research and development of ultrafast superconducting single-photon detectors (SSPDs) based on ultrathin NbN nanostructures. Our SSPDs were made of the 4-nm-thick NbN films with Tc ~11 K, patterned as meander-shaped, 100-nm-wide strips, and covering an area of 10×10 μm2. The detectors exploit a combined detection mechanism, where upon a single-photon absorption, a hotspot of excited electrons and redistribution of the biasing supercurrent, jointly produce a picosecond voltage transient signal across the superconducting nanostripe. The SSPDs are typically operated at 4.2 K, but their sensitivity in the infrared radiation range can be significantly improved by lowering the operating temperature from 4.2 K to 2 K. When operated at 2 K, the SSPD quantum efficiency (QE) for visible light photons reaches 30-40%, which is the saturation value limited by the optical absorption of our 4-nm-thick NbN film. With the wavelength increase of the incident photons,the QE of SSPDs decreases significantly, but even at the wavelength of 6 μm, the detector is able to count single photons and exhibits QE of about 10-2 %. The dark (false) count rate at 2 K is as low as 2x10-4 s,-1 which makes our detector essentially a background-limited sensor. The very low dark-count rate results in a noise equivalent power (NEP) below 10-18 WHz-1/2 for the mid-infrared range (6 μm). Further improvement of the SSPD performance in the mid-infrared range can be obtained by substituting NbN for another, lower-Tc materials with a narrow superconducting gap and low quasiparticles diffusivity. The use of such superconductors should shift the cutoff wavelength below 10 μm.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 16, 2005•2 citations

Ultrafast superconducting single-photon detectors for infrared wavelength quantum communications

A. Verevkin, Aaron J. Pearlman, Wojtek Slysz +11 more

We have developed a new class of superconducting single-photon detectors (SSPDs) for ultrafast counting of infrared (IR) photons for secure quantum communications. The devices are operated on the quantum detection mechanism, based on the photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-wide superconducting stripe. The detectors are fabricated from 3.5-nm-thick NbN films and they operate at 4.2 K inside a closed-cycle refrigerator or liquid helium cryostat. Various continuous and pulsed laser sources have been used in our experiments, enabling us to determine the detector experimental quantum efficiency (QE) in the photon-counting mode, response time, time jitter, and dark counts. Our 3.5-nm-thick SSPDs reached QE above 15% for visible light photons and 5% at 1.3 - 1.5 μm infrared range. The measured real-time counting rate was above 2 GHz and was limited by the read-out electronics (intrinsic response time is <30 ps). The measured jitter was <18 ps, and the dark counting rate was <0.01 per second. The measured noise equivalent power (NEP) is 2 x 10-18 W/Hz1/2 at λ = 1.3 μm. In near-infrared range, in terms of the counting rate, jitter, dark counts, and overall sensitivity, the NbN SSPDs significantly outperform their semiconductor counterparts. An ultrafast quantum cryptography communication technology based on SSPDs is proposed and discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 5, 2003•1 citation

Ultrafast superconducting single-photon optical detectors

Roman Sobolewski, J. Zhang, Wojciech Słysz +12 more

We present a new class of single-photon devices for counting of both visible and infrared photons. Our superconducting single-photon detectors (SSPDs) are characterized by the intrinsic quantum efficiency (QE) reaching up to 100%, above 10 GHz counting rate, and negligible dark counts. The detection mechanism is based on the photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-wide superconducting stripe. The devices are fabricated from 3.5-nm-thick NbN films and operate at 4.2 K, well below the NbN superconducting transition temperature. Various continuous and pulsed laser sources in the wavelength range from 0.4 μm up to >3 μm were implemented in our experiments, enabling us to determine the detector QE in the photon-counting mode, response time, and jitter. For our best 3.5-nm-thick, 10×10 μm2-area devices, QE was found to reach almost 100% for any wavelength shorter than about 800 nm. For longer-wavelength (infrared) radiation, QE decreased exponentially with the photon wavelength increase. Time-resolved measurements of our SSPDs showed that the system-limited detector response pulse width was below 150 ps. The system jitter was measured to be 35 ps. In terms of the counting rate, jitter, and dark counts, the NbN SSPDs significantly outperform their semiconductor counterparts. Already identifeid and implemented applications of our devices range from noninvasive testing of semiconductor VLSI circuits to free-space quantum communications and quantum cryptography.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 8, 2003•3 citations
We extend the concept of the superconducting quantum counter in order to develop a new quantum detector for submillimeter astronomy. The detector exploits a cumulative detection mechanism, in which the response appears due to successive formation of the normal spot and a resistive domain in a narrow strip carrying sub-critical supercurrent. The intrinsic recovery time of the counter is partly determined by diffusion of nonequilibrium electrons and, thus, depends on the energy of detected photons. Depending on the superconducting material used and operation conditions, such detector may have cut-off wavelengths for the single-photon regime ranging from terahertz waves to visible light and simultaneously provide a moderate energy resolution. We simulated performance of the background-limited submillimeter direct detector from Ti having the 100-micrometer cut-off wavelength, low dark count rate and intrinsic 10-21 W Hz-1/2 noise equivalent power for 4-K background radiation. We present first results obtained with a detector prototype fabricated from ultra-thin Nb film.
We analyze the ultimate performance of a superconducting quantum detector in order to meet requirements for applications in near-infrared astronomy and X-ray spectroscopy. The detector exploits a combined detection mechanism, in which avalanche quasiparticle multiplication and the supercurrent jointly produce a voltage response to a single absorbed photon via successive formation of a photon-induced and a current-induced normal hotspot in a narrow superconducting strip. The response time of the detector should increase with the photon energy providing energy resolution. Depending on the superconducting material and operation conditions, the cut-off wavelength for the single-photon detection regime varies from infrared waves to visible light. We simulated the performance of the background-limited infrared direct detector and X-ray photon counter utilizing the above mechanism. Low dark count rate and intrinsic low-frequency cut-off allow for realizing a background limited noise equivalent power of 10−20 W Hz−1/2 for a far-infrared direct detector exposed to 4-K background radiation. At low temperatures, the intrinsic response time of the counter is rather determined by diffusion of nonequilibrium electrons than by the rate of energy transfer to phonons. Therefore, thermal fluctuations do not hamper energy resolution of the X-ray photon counter that should be better than 10−3 for 6-keV photons. Comparison of new data obtained with a Nb based detector and previously reported results on NbN quantum detectors support our estimates of ultimate detector performance.
We analyze the spectral performance of recently developed single-photon quantum detector that consists of a narrow, nanometer sized meander-line made from ultra-thin superconducting film. The detector exploits a combined detection mechanism, in which avalanche multiplication of quasiparticles after absorption of a single photon and the bias current jointly produce a normal domain that results in a voltage pulse developing between the meander ends. With either the wavelength increase or the bias current decrease, the single-photon detection regime exhibits a cut-off. The wavelength, at which the cut-off occurs, varies from infrared waves to visible light depending on the superconducting material and operation conditions. Structural and geometrical non-uniformities of the meander line smooth out the otherwise expected sharp drop of the detection efficiency beyond the cut-off. We refine the early detector model and propose a tentative explanation of how superconducting fluctuations may additionally extend the detection efficiency beyond the cut-off wavelength.
We discuss the design for a submillimeter-wave photometer, using a combination of superconducting and single-electron devices, which would have high quantum efficiency, very low noise-equivalent powers, and eventually even submicrosecond timing resolution. The absorption of above-gap photons occurs in a small strip of superconducting Al, whose normal-state resistance can be matched efficiently to an antenna of a higher gap (Nb) superconductor. The quasiparticles produced by photon absorption are then confined via Andreev reflection, and forced to tunnel through a small SIS tunnel junction. The tunneling time is much shorter than the known (>10 /spl mu/s) quasiparticle recombination time, so collection efficiency will be high. The device sensitivity would be limited by the small subgap current in the high-quality Al/AlO/sub x//Al tunnel junction at temperatures (100 mK) well below T/sub c/. Scaling based on the larger junctions used in X-ray detector applications suggests that the total dark current can be <0.1 pA, or of order 10/sup 5/ electrons/second, corresponding to an NEP of less than 10/sup -19/ W//spl radic/Hz at 500 microns (600 GHz). The photocurrent will be measured using a fast single-electron transistor (RF-SET), which allows a shot-noise-limited performance even for the very small currents delivered from this low capacitance and high impedance SIS junction. Results of initial fabrication and dc characterization of an integrated photodetector are also given.
We report on our progress in research and development of ultrafast superconducting single-photon detectors (SSPDs) based on ultrathin NbN nanostructures. Our SSPDs were made of the 4-nm-thick NbN films with Tc ~11 K, patterned as meander-shaped, 100-nm-wide strips, and covering an area of 10×10 μm2. The detectors exploit a combined detection mechanism, where upon a single-photon absorption, a hotspot of excited electrons and redistribution of the biasing supercurrent, jointly produce a picosecond voltage transient signal across the superconducting nanostripe. The SSPDs are typically operated at 4.2 K, but their sensitivity in the infrared radiation range can be significantly improved by lowering the operating temperature from 4.2 K to 2 K. When operated at 2 K, the SSPD quantum efficiency (QE) for visible light photons reaches 30-40%, which is the saturation value limited by the optical absorption of our 4-nm-thick NbN film. With the wavelength increase of the incident photons,the QE of SSPDs decreases significantly, but even at the wavelength of 6 μm, the detector is able to count single photons and exhibits QE of about 10-2 %. The dark (false) count rate at 2 K is as low as 2x10-4 s,-1 which makes our detector essentially a background-limited sensor. The very low dark-count rate results in a noise equivalent power (NEP) below 10-18 WHz-1/2 for the mid-infrared range (6 μm). Further improvement of the SSPD performance in the mid-infrared range can be obtained by substituting NbN for another, lower-Tc materials with a narrow superconducting gap and low quasiparticles diffusivity. The use of such superconductors should shift the cutoff wavelength below 10 μm.
We have developed a new class of superconducting single-photon detectors (SSPDs) for ultrafast counting of infrared (IR) photons for secure quantum communications. The devices are operated on the quantum detection mechanism, based on the photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-wide superconducting stripe. The detectors are fabricated from 3.5-nm-thick NbN films and they operate at 4.2 K inside a closed-cycle refrigerator or liquid helium cryostat. Various continuous and pulsed laser sources have been used in our experiments, enabling us to determine the detector experimental quantum efficiency (QE) in the photon-counting mode, response time, time jitter, and dark counts. Our 3.5-nm-thick SSPDs reached QE above 15% for visible light photons and 5% at 1.3 - 1.5 μm infrared range. The measured real-time counting rate was above 2 GHz and was limited by the read-out electronics (intrinsic response time is <30 ps). The measured jitter was <18 ps, and the dark counting rate was <0.01 per second. The measured noise equivalent power (NEP) is 2 x 10-18 W/Hz1/2 at λ = 1.3 μm. In near-infrared range, in terms of the counting rate, jitter, dark counts, and overall sensitivity, the NbN SSPDs significantly outperform their semiconductor counterparts. An ultrafast quantum cryptography communication technology based on SSPDs is proposed and discussed.
We present a new class of single-photon devices for counting of both visible and infrared photons. Our superconducting single-photon detectors (SSPDs) are characterized by the intrinsic quantum efficiency (QE) reaching up to 100%, above 10 GHz counting rate, and negligible dark counts. The detection mechanism is based on the photon-induced hotspot formation and subsequent appearance of a transient resistive barrier across an ultrathin and submicron-wide superconducting stripe. The devices are fabricated from 3.5-nm-thick NbN films and operate at 4.2 K, well below the NbN superconducting transition temperature. Various continuous and pulsed laser sources in the wavelength range from 0.4 μm up to >3 μm were implemented in our experiments, enabling us to determine the detector QE in the photon-counting mode, response time, and jitter. For our best 3.5-nm-thick, 10×10 μm2-area devices, QE was found to reach almost 100% for any wavelength shorter than about 800 nm. For longer-wavelength (infrared) radiation, QE decreased exponentially with the photon wavelength increase. Time-resolved measurements of our SSPDs showed that the system-limited detector response pulse width was below 150 ps. The system jitter was measured to be 35 ps. In terms of the counting rate, jitter, and dark counts, the NbN SSPDs significantly outperform their semiconductor counterparts. Already identifeid and implemented applications of our devices range from noninvasive testing of semiconductor VLSI circuits to free-space quantum communications and quantum cryptography.