Journal of Physics E Scientific Instruments

Polarisation measurement of a He(23Si1) atomic beam

J Giroux, Robby Lapointe, R.J. Slobodrian

Published Nov 1, 1984• 1 citation
Publisher

Abstract

An atomic beam of He in the metastable 2 3 S 1 state can be atomic-spin-polarised by Stern-Gerlach selection using a sextupole magnet. The authors report the first measurements of the polarisation obtained by this method. The authors have determined the metastable beam velocity distribution from a time-of-flight measurement. The distribution was found to be in the range of thermal velocities. The selection efficiency of the sextupole magnet was studied using a Stern-Gerlach deflection with an inhomogeneous dipole field. The experimental results give a vector polarisation close to 95%. Thus, the technique can be useful for many applications.

DOI
10.1088/0022-3735/17/11/013

Related papers

Atom interferometer using two Stern-Gerlach magnets

Kenneth H. Rubin, M. Eminyan, F Perales +8 more

An atom interferometer using two Stern-Gerlach magnets as polariser and analyser is described. The interferometer was first operated with a thermal beam of ground state potassium atoms. In that case the beam splitters are two radio-frequency zones within a transverse homogeneous magnetic field building a coherent superposition of Zeeman states. Ramsey fringes are obtained by scanning the RF-frequency through the resonance profile. Pulsing the RF power allows to get the time-of-flight distribution of the beam. Atomic interference fringes (``Stern-Gerlach fringes'') are observed when the magnitude of an inhomogeneous magnetic field located in between the beam splitters is scanned. When the inhomogeneous field is also pulsed, the scalar Bohm-Aharonov effect is observed. The use of metastable helium atoms (He*23S) in place of potassium atoms is proposed. In addition to the usual advantages provided by metastable atoms of high internal energy, this atom offers the specific advantage to behave as an ideal spin-one particle. This allows us to greatly simplify the polarisation scheme of the interferometer. Possible applications involving transversally inhomogeneous magnetic fields are given and limitations due to the finite source size and angular aperture are discussed.

Laser Physics Letters•Mar 9, 2004•12 citations

A spin flipper for reversal of polarisation in a thermal atomic beam

W Schroder, G. Baum

By using the method of diabatic passage, the authors have developed a spin flipper which allows a rapid and convenient reversal of the atomic spins. The spin flipper was tested with a polarised lithium atomic beam by analysing the atomic beam polarisation with the help of a second spin-flip region and a sextupole magnet. The reversal efficiency was measured to be 0.98 which is in agreement with the calculation. The flipper is especially useful in low-energy electron-atom crossed-beam collision studies. The experimental arrangement used also allows a precise determination of the atomic beam polarisation.

Journal of Physics E Scientific Instruments•Jan 1, 1983•28 citations

Dipole polarizability of 2S13 and 2S01 metastable helium measured by the electric deflection time-of-flight method

David A. Crosby, Jens C. Zorn

The static dipole polarizability of helium atoms in the metastable $2^{3}S_{1}$ and $2^{1}S_{0}$ states has been determined by measuring the deflection of a beam of excited helium atoms that is caused by an inhomogeneous electric field of known properties. The necessary velocity distribution information is obtained from time-of-flight measurements, and a resonance quenching technique made it possible to distinguish the singlet and triplet components of the beam. The results, $\ensuremath{\alpha}(2^{3}S_{1})=(44.6\ifmmode\pm\else\textpm\fi{}3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ ${\mathrm{cm}}^{3}$ and $\ensuremath{\alpha}(2^{1}S_{0})=(108\ifmmode\pm\else\textpm\fi{}13)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ ${\mathrm{cm}}^{3}$, agree with the theoretical value that has been used to calibrate earlier polarizability measurements of the alkali metals and the heavier noble gases.

Physical Review A•Aug 1, 1977•25 citations

Use of hexapole magnet and spin flipper combined with time-of-flight analysis to characterize state-selected paramagnetic atomic/molecular beams

Mitsunori Kurahashi

In the past, the Stern–Gerlach experiment has been used as a standard method for analyzing the population of magnetic substates contained in spin-polarized and/or state-selected atomic/molecular beams. However, this experiment is quite demanding due to its low signal intensity and difficulty in beam alignment. The present study shows that the use of a hexapole magnet and a spin flipper, together with the time-of-flight analysis, allows us to conduct an almost equivalent analysis while greatly improving the signal intensity. Applications to the analysis of spin-polarized triplet excited helium and state-selected O2( 3 Σg−) beams are presented.

Review of Scientific Instruments•Jan 1, 2021•7 citations

Focusing and spin polarization of atomic hydrogen beam

Y. Nagaya, H. Nakatsu, Shohei Ogura +4 more

We have developed a spin-polarized-hydrogen beam with a hexapole magnet. By combining the beam chopper and pulsed laser ionization detection, the time-of-flight of the hydrogen beam was measured, and the dependence of the beam profile on the velocity was acquired, which was consistent with the beam trajectory simulations. The spin polarization of the beam was analyzed by using the Stern-Gerlach-type magnet in combination with the spatial scan of the detection laser. The spin polarization was about 95% at a focusing condition due to the hexapole magnet. The polarization was, on the other hand, reduced to about 70% for the beam at higher velocities, which is consistent with simulation results.

The Journal of Chemical Physics•Nov 2, 2021•3 citations

A Method for Measuring the Weak Value of Spin for Metastable Atoms

R. Flack, Vincenzo Monachello, Basil J. Hiley +1 more

A method for measuring the weak value of spin for atoms is proposed using a variant of the original Stern-Gerlach apparatus. A full simulation of an experiment for observing the real part of the weak value using the impulsive approximation has been carried out. Our predictions show a displacement of the beam of helium atoms in the metastable 23S1 state, Δw, that is within the resolution of conventional microchannel plate detectors indicating that this type of experiment is feasible. Our analysis also determines the experimental parameters that will give an accurate determination of the weak value of spin. Preliminary experimental results are shown for helium, neon and argon in the 23S1 and 3P2 metastable states, respectively.

Entropy•Jul 30, 2018•4 citations
An atomic beam of He in the metastable 2 3 S 1 state can be atomic-spin-polarised by Stern-Gerlach selection using a sextupole magnet. The authors report the first measurements of the polarisation obtained by this method. The authors have determined the metastable beam velocity distribution from a time-of-flight measurement. The distribution was found to be in the range of thermal velocities. The selection efficiency of the sextupole magnet was studied using a Stern-Gerlach deflection with an inhomogeneous dipole field. The experimental results give a vector polarisation close to 95%. Thus, the technique can be useful for many applications.
An atom interferometer using two Stern-Gerlach magnets as polariser and analyser is described. The interferometer was first operated with a thermal beam of ground state potassium atoms. In that case the beam splitters are two radio-frequency zones within a transverse homogeneous magnetic field building a coherent superposition of Zeeman states. Ramsey fringes are obtained by scanning the RF-frequency through the resonance profile. Pulsing the RF power allows to get the time-of-flight distribution of the beam. Atomic interference fringes (``Stern-Gerlach fringes'') are observed when the magnitude of an inhomogeneous magnetic field located in between the beam splitters is scanned. When the inhomogeneous field is also pulsed, the scalar Bohm-Aharonov effect is observed. The use of metastable helium atoms (He*23S) in place of potassium atoms is proposed. In addition to the usual advantages provided by metastable atoms of high internal energy, this atom offers the specific advantage to behave as an ideal spin-one particle. This allows us to greatly simplify the polarisation scheme of the interferometer. Possible applications involving transversally inhomogeneous magnetic fields are given and limitations due to the finite source size and angular aperture are discussed.
By using the method of diabatic passage, the authors have developed a spin flipper which allows a rapid and convenient reversal of the atomic spins. The spin flipper was tested with a polarised lithium atomic beam by analysing the atomic beam polarisation with the help of a second spin-flip region and a sextupole magnet. The reversal efficiency was measured to be 0.98 which is in agreement with the calculation. The flipper is especially useful in low-energy electron-atom crossed-beam collision studies. The experimental arrangement used also allows a precise determination of the atomic beam polarisation.
The static dipole polarizability of helium atoms in the metastable 23S12^{3}S_{1}23S1​ and 21S02^{1}S_{0}21S0​ states has been determined by measuring the deflection of a beam of excited helium atoms that is caused by an inhomogeneous electric field of known properties. The necessary velocity distribution information is obtained from time-of-flight measurements, and a resonance quenching technique made it possible to distinguish the singlet and triplet components of the beam. The results, $\ensuremath{\alpha}(2^{3}S_{1})=(44.6\ifmmode\pm\else\textpm\fi{}3)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ cm3{\mathrm{cm}}^{3}cm3 and $\ensuremath{\alpha}(2^{1}S_{0})=(108\ifmmode\pm\else\textpm\fi{}13)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}24}$ cm3{\mathrm{cm}}^{3}cm3, agree with the theoretical value that has been used to calibrate earlier polarizability measurements of the alkali metals and the heavier noble gases.
In the past, the Stern–Gerlach experiment has been used as a standard method for analyzing the population of magnetic substates contained in spin-polarized and/or state-selected atomic/molecular beams. However, this experiment is quite demanding due to its low signal intensity and difficulty in beam alignment. The present study shows that the use of a hexapole magnet and a spin flipper, together with the time-of-flight analysis, allows us to conduct an almost equivalent analysis while greatly improving the signal intensity. Applications to the analysis of spin-polarized triplet excited helium and state-selected O2( 3 Σg−) beams are presented.
We have developed a spin-polarized-hydrogen beam with a hexapole magnet. By combining the beam chopper and pulsed laser ionization detection, the time-of-flight of the hydrogen beam was measured, and the dependence of the beam profile on the velocity was acquired, which was consistent with the beam trajectory simulations. The spin polarization of the beam was analyzed by using the Stern-Gerlach-type magnet in combination with the spatial scan of the detection laser. The spin polarization was about 95% at a focusing condition due to the hexapole magnet. The polarization was, on the other hand, reduced to about 70% for the beam at higher velocities, which is consistent with simulation results.
A method for measuring the weak value of spin for atoms is proposed using a variant of the original Stern-Gerlach apparatus. A full simulation of an experiment for observing the real part of the weak value using the impulsive approximation has been carried out. Our predictions show a displacement of the beam of helium atoms in the metastable 23S1 state, Δw, that is within the resolution of conventional microchannel plate detectors indicating that this type of experiment is feasible. Our analysis also determines the experimental parameters that will give an accurate determination of the weak value of spin. Preliminary experimental results are shown for helium, neon and argon in the 23S1 and 3P2 metastable states, respectively.