Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Heisenberg-limit interferometry with four-wave mixers operating in a nonlinear regime

Christopher C. Gerry

Published Mar 17, 2000• 152 citations
Publisher

Abstract

A model of a four-wave mixer operated in a nonlinear regime, studied by Yurke and Stoler [Phys. Rev. A 35, 4846 (1987)], is reexamined. Yurke and Stoler have shown that this device, under a certain condition, acts as an even-odd filter, switching even-photon-number states from the pump mode to the signal mode. An initial coherent state in the pump is converted into an entanglement of even and odd coherent states with vacuum states in the output signal and pump modes. We point out that under a different condition and with an even-photon-number state initially in the pump and a vacuum in the signal, the device creates a maximally entangled state between the number state and the vacuum. Using the device to replace the first beamsplitter of a Mach-Zehnder interferometer, phase uncertainties at the Heisenberg limit $(\ensuremath{\Delta}\ensuremath{\varphi}=1/n)$ can be obtained. Since number states are difficult to generate, we point out that an even coherent state obtained from the output of one device can be used as input to a second to achieve the phase uncertainties $\ensuremath{\Delta}\ensuremath{\varphi}{=1/n}_{e},$ where ${n}_{e}$ is the average photon number of the even coherent state.

DOI
10.1103/physreva.61.043811

Related papers

Heisenberg-limited interferometry and photolithography with nonlinear four-wave mixing

Christopher C. Gerry, Adil Benmoussa

Maximally entangled photonic states of a two-mode field have applications in Heisenberg-limit interferometry and in photolithography where they may be used to transfer images with resolutions exceeding the Rayleigh diffraction limit. In a recent paper by one of us [C. C. Gerry, Phys. Rev. A 61, 043811 (2000)] it was shown that a nonlinear four-wave mixer could produce the requisite states for input states containing only even photon numbers. For superpositions of even number states the output is just a superposition of maximally entangled even states. In the present paper we extend the earlier work to consider both even coherent states and squeezed vacuum states as inputs and study their applications to interferometry and lithography.

Physical Review A•Feb 26, 2002•36 citations

Nonlinear interferometer as a resource for maximally entangled photonic states: Application to interferometry

Christopher C. Gerry, Adil Benmoussa, Richard A. Campos

Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.

Physical Review A•Jul 11, 2002•106 citations

Quantum behavior of a four-wave mixer operated in a nonlinear regime

Bernard Yurke, David Stoler

A four-wave mixer model is presented for which exact analytic results can be obtained in a regime where the usual perturbation procedures no longer apply. It is shown that under suitable conditions the output of such a four-wave mixer consists of a superposition of macroscopically distinguishable states. Such states can be identified with a homodyne detector which is able to observe the interference between the macroscopically distinguishable components. Further, it is shown that the device can act as an even-odd filter which will switch incoming pump light between two output ports depending on whether there is an even or odd number of pump photons.

Physical Review A•Jun 1, 1987•67 citations

Optical interferometry at the Heisenberg limit with twin Fock states and parity measurements

Richard A. Campos, Christopher C. Gerry, Adil Benmoussa

Holland and Burnett [Phys. Rev. Lett. 71, 1355 (1993)] have argued that twin Fock states of equal photon number $N$ injected at both input ports of a Mach-Zehnder interferometer lead to phase measurements with accuracies approaching the Heisenberg limit $\ensuremath{\Delta}{\ensuremath{\varphi}}_{\mathrm{HL}}=1/(2N).$ However, the method of phase detection suggested by those authors, obtaining the difference of the photocurrents at the output ports of the interferometer, is not sensitive to the phase difference between the two interferometer paths; in fact, the photocurrent vanishes. In this paper we show that the use of parity measurements on just one of the output modes not only is sensitive to the phase difference but that the sensitivity approaches the Heisenberg limit for large $N.$

Physical Review A•Aug 25, 2003•217 citations

Interferometers and minimum-uncertainty states

Mark S. Hillery, Leonard D. Mlodinow

Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.

Physical Review A•Aug 1, 1993•97 citations

Coherent mixed with squeezed vacuum light interferometry: parity detection hits the Heisenberg limit

Kaushik Parasuram Seshadreesan, Petr M. Anisimov, Hwang Lee +1 more

Mach-Zehnder interferometry based on mixing the coherent and the squeezed vacuum states of light has Heisenberg limited capabilities for phase estimation. This is also, because the quantum Cramer-Rao bound on sensitivity of phase estimation with the above interferometric scheme reaches the Heisenberg limit when the inputs are mixed in hear equal proportions. We show that a detection strategy based on the measurement of parity of photon number in one of the output modes of the interferometer saturates the quantum Cramer-Rao bound of the interferometric scheme, and therefore- as a consequence- hits the Heisenberg limit when the inputs are mixed in equal intensities.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 9, 2012•1 citation
A model of a four-wave mixer operated in a nonlinear regime, studied by Yurke and Stoler [Phys. Rev. A 35, 4846 (1987)], is reexamined. Yurke and Stoler have shown that this device, under a certain condition, acts as an even-odd filter, switching even-photon-number states from the pump mode to the signal mode. An initial coherent state in the pump is converted into an entanglement of even and odd coherent states with vacuum states in the output signal and pump modes. We point out that under a different condition and with an even-photon-number state initially in the pump and a vacuum in the signal, the device creates a maximally entangled state between the number state and the vacuum. Using the device to replace the first beamsplitter of a Mach-Zehnder interferometer, phase uncertainties at the Heisenberg limit (\ensuremathΔ\ensuremathφ=1/n)(\ensuremath{\Delta}\ensuremath{\varphi}=1/n)(\ensuremathΔ\ensuremathφ=1/n) can be obtained. Since number states are difficult to generate, we point out that an even coherent state obtained from the output of one device can be used as input to a second to achieve the phase uncertainties \ensuremathΔ\ensuremathφ=1/ne,\ensuremath{\Delta}\ensuremath{\varphi}{=1/n}_{e},\ensuremathΔ\ensuremathφ=1/ne​, where ne{n}_{e}ne​ is the average photon number of the even coherent state.
Maximally entangled photonic states of a two-mode field have applications in Heisenberg-limit interferometry and in photolithography where they may be used to transfer images with resolutions exceeding the Rayleigh diffraction limit. In a recent paper by one of us [C. C. Gerry, Phys. Rev. A 61, 043811 (2000)] it was shown that a nonlinear four-wave mixer could produce the requisite states for input states containing only even photon numbers. For superpositions of even number states the output is just a superposition of maximally entangled even states. In the present paper we extend the earlier work to consider both even coherent states and squeezed vacuum states as inputs and study their applications to interferometry and lithography.
Nonlinear interferometers are Mach-Zehnder interferometers with Kerr media in either one or both arms. We refer to these devices, respectively, as the asymmetric and symmetric nonlinear interferometers. In the asymmetric case, with one input mode in the vacuum, it is possible to generate maximally entangled photonic states or superpositions of such states. We consider the device as a resource of entangled states for applications to Heisenberg-limited interferometry. Interferometry with the maximally entangled states cannot be performed by simply subtracting the output photocounts as in standard interferometry. Instead, one must perform parity measurements on only one of the output beams. We show that the symmetric nonlinear interferometer, with one input mode in the vacuum, may be used to perform such parity measurements. The same device is shown to produce, with an input coherent state and upon projective measurements, even or odd coherent states, examples of the Schr\"odinger-cat states.
A four-wave mixer model is presented for which exact analytic results can be obtained in a regime where the usual perturbation procedures no longer apply. It is shown that under suitable conditions the output of such a four-wave mixer consists of a superposition of macroscopically distinguishable states. Such states can be identified with a homodyne detector which is able to observe the interference between the macroscopically distinguishable components. Further, it is shown that the device can act as an even-odd filter which will switch incoming pump light between two output ports depending on whether there is an even or odd number of pump photons.
Holland and Burnett [Phys. Rev. Lett. 71, 1355 (1993)] have argued that twin Fock states of equal photon number NNN injected at both input ports of a Mach-Zehnder interferometer lead to phase measurements with accuracies approaching the Heisenberg limit $\ensuremath{\Delta}{\ensuremath{\varphi}}_{\mathrm{HL}}=1/(2N).$ However, the method of phase detection suggested by those authors, obtaining the difference of the photocurrents at the output ports of the interferometer, is not sensitive to the phase difference between the two interferometer paths; in fact, the photocurrent vanishes. In this paper we show that the use of parity measurements on just one of the output modes not only is sensitive to the phase difference but that the sensitivity approaches the Heisenberg limit for large N.N.N.
Minimum-uncertainty states in variables which are quadratic in mode creation and annihilation operators can be used to increase the accuracy of interferometric measurements. For a general interferometer we show how to find the relevant uncertainty relation. We consider two specific examples, a Mach-Zehnder interferometer and a Mach-Zehnder interferometer in which the first beam splitter has been replaced by a four-wave mixer. For both devices su(2) squeezed minimum-uncertainty states can be used to achieve phase-measurement accuracies of 1/N, where N is the total photon number at the input. We also describe a method of producing approximate versions of these states.
Mach-Zehnder interferometry based on mixing the coherent and the squeezed vacuum states of light has Heisenberg limited capabilities for phase estimation. This is also, because the quantum Cramer-Rao bound on sensitivity of phase estimation with the above interferometric scheme reaches the Heisenberg limit when the inputs are mixed in hear equal proportions. We show that a detection strategy based on the measurement of parity of photon number in one of the output modes of the interferometer saturates the quantum Cramer-Rao bound of the interferometric scheme, and therefore- as a consequence- hits the Heisenberg limit when the inputs are mixed in equal intensities.