Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Radio frequency SQUIDs operating at 77 K with 1 GHz lumped-element tank circuits

Donghao He, Xian-Lin Zeng, Hans‐Joachim Krause, Helmut Soltner, F. Rüders, Y. Zhang

Published Feb 23, 1998• 36 citations
Publisher

Abstract

We have developed a matching scheme for the operation of a rf superconducting quantum interference device (SQUID) with a lumped-element tank circuit at pumping frequencies up to 1 GHz. This conventional LC resonant circuit is inductively coupled to a matching coil, which is connected to the 50 Ω transmission line. We characterized the flux noise of high-temperature rf SQUIDs at resonant frequencies between 221 and 950 MHz. At about 900 MHz, we obtained the white flux noise of about 14.6 μφ0/Hz with a SQUID inductance LS=150 pH and 20 μφ0/Hz with LS=260 pH. Several of such tank circuits can be driven in parallel or in series with only one cable.

DOI
10.1063/1.120611

Related papers

Operation of high-sensitivity radio frequency superconducting quantum interference device magnetometers with superconducting coplanar resonators at 77 K

Y. Zhang, W. Zander, Jürgen Schubert +6 more

We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.

Applied Physics Letters•Aug 4, 1997•54 citations

Radio frequency bias current scheme for dc superconducting quantum interference device

Y. Zhang, Dongfeng He, N. Wolters +7 more

We have developed a radio frequency bias current scheme with reversal frequency up to 50 MHz for dc superconducting quantum interference devices (SQUIDs). The SQUID and the readout electronics, were connected via a quarter wavelength (/spl lambda//4) transmission line. This transmission line not only transported the SQUID signal, but also served as the resonant matching circuit. For a dc SQUID of inductance 115 pH (loop size 75/spl times/75 /spl mu/m/sup 2/), we measured a flux noise of 33 /spl mu//spl phi//sub 0///spl radic/Hz at 77 K in the flux locked loop configuration. The corner frequency of 1/f noise was less than 0.5 Hz.

IEEE Transactions on Applied Superconductivity•Jun 1, 1999•0 citations

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

Review of Scientific Instruments•Jun 1, 2006•0 citations

Operation of high-temperature rf SQUID magnetometers using dielectric SrTiO3 resonators

Y. Zhang, M. Gottschlich, Helmut Soltner +4 more

The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.

Applied Physics Letters•Nov 20, 1995•16 citations

Characterization of the low-frequency noise in high-temperature radio frequency superconducting quantum interference devices cooled in static magnetic fields

J. Borgmann, P. David, Raphael Otto +2 more

We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.

Applied Physics Letters•Feb 15, 1999•1 citation

Low-noise YBa2Cu3O7 rf SQUID magnetometer

Yi Zhang, H.-M. Mück, Klaus Dieter Herrmann +4 more

A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.

Applied Physics Letters•Feb 3, 1992•81 citations
We have developed a matching scheme for the operation of a rf superconducting quantum interference device (SQUID) with a lumped-element tank circuit at pumping frequencies up to 1 GHz. This conventional LC resonant circuit is inductively coupled to a matching coil, which is connected to the 50 Ω transmission line. We characterized the flux noise of high-temperature rf SQUIDs at resonant frequencies between 221 and 950 MHz. At about 900 MHz, we obtained the white flux noise of about 14.6 μφ0/Hz with a SQUID inductance LS=150 pH and 20 μφ0/Hz with LS=260 pH. Several of such tank circuits can be driven in parallel or in series with only one cable.
We have developed a novel coplanar resonator serving as a tank circuit for radio frequency washer superconducting quantum interference devices (SQUIDs). Two coplanar lines surrounded the circular flux concentrator washer, 13.4 mm in diameter. The SQUID, 3.5 mm in diameter, was coupled to the concentrator in the flip-chip configuration. All parts were fabricated from single-layer epitaxial YBa2Cu3O7 films on LaAlO3 substrates. In this layout, the resonant frequency could be set between 600 and 850 MHz. With SQUID loops of 100×100 μm2 (SQUID) inductance Ls=150 pH or 10×500 μm2 (Ls=260 pH), we determined at 77 K white flux noise levels Sφ1/2 of 1.0×10−5 and 1.5×10−5φ0/Hz, respectively. Both figures corresponded to the field resolution of about 30 fT/Hz.
We have developed a radio frequency bias current scheme with reversal frequency up to 50 MHz for dc superconducting quantum interference devices (SQUIDs). The SQUID and the readout electronics, were connected via a quarter wavelength (/spl lambda//4) transmission line. This transmission line not only transported the SQUID signal, but also served as the resonant matching circuit. For a dc SQUID of inductance 115 pH (loop size 75/spl times/75 /spl mu/m/sup 2/), we measured a flux noise of 33 /spl mu//spl phi//sub 0///spl radic/Hz at 77 K in the flux locked loop configuration. The corner frequency of 1/f noise was less than 0.5 Hz.
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
The operation of YBa2Cu3O7 rf superconducting quantum interference devices (SQUIDs) using a dielectric SrTiO3 resonator as tank circuit was tested. At 77 K, we attained for such resonators unloaded quality factors Q0 up to 7000 at resonant frequencies near 1 GHz, when measuring without electromagnetic shielding. For a washer SQUID with an area of 4×4 mm2 and an inductance of ≂100 pH, which was properly coupled to the resonator, we measured an approximately 60 μV peak-to-peak SQUID signal and a white flux noise spectral density of SΦ1/2=1×10−5Φ0/√Hz, corresponding to a field sensitivity of BN=105 fT/√Hz. With an additional single-layer flux transformer with a diameter of the pickup loop of 22 mm in flip-chip arrangement, the field sensitivity was improved to 30 fT/√Hz.
We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.
A superconducting quantum interferometer device (SQUID) electronics with tank frequencies near 150 MHz was constructed to enhance the rf SQUID sensitivity. By these means we characterized our YBa2Cu3O7 thin-film rf SQUIDs with step-edge junctions immersed in liquid N2. We obtained transfer function values of over 40 μV/Φ0, at a 50 Ω input impedance, for both hysteretic and dispersive mode of rf SQUID operation. The rms white and 1/f flux noise levels were significantly lower than at the tank frequency of 20 MHz. The best magnetic field sensitivity at 77 K was 0.9 pT/Hz1/2, and the energy resolution 1.4×10−28 J/Hz, down to 0.3 Hz.