Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Measurement of the differential polarizability of the 698 nm clock transition of strontium for evaluation of optical lattice clocks

Thomas Middelmann, Stephan Falke, Christian Lisdat, Uwe Sterr

Published Jul 1, 2012• 0 citations
Publisher

Abstract

A modification to a successfull technique to measure static differential polarizabilities of ultracold atoms and molecules is presented. Ultracold atoms are trapped in a magic wavelength optical lattice and transported into the field of a precision capacitor. The change of the transition frequency induced by the applied field, which is controlled to better than 10-4, is measured. For atomic clocks, the difference of the static polarizabilies of ground and excited state is closely related to their response to a blackbody radiation field, which is a significant contribution to the uncertainty budget of many atomic clocks.

DOI
10.1109/cpem.2012.6251081

Related papers

Bestimmung des Einflusses thermischer Strahlung auf eine optische Strontium-Gitteruhr

Thomas Middelmann

Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time.This corresponds to a fractional uncertainty of the clock frequency on the level of 10 -18 and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for.In strontium optical lattice clocks an ensemble of ultracold strontium atoms is conned in an optical lattice, to allow for spectroscopy of the reference transition 5s 2 1 S 0 5s5p 3 P 0 in the Lamb-Dicke regime.The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR).The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 × 10 -16 .In this thesis for the rst time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation.At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz.The achieved uncertainty contributes with 5 × 10 -18 to the fractional systematic uncertainty of the clock frequency.The determination is based on a precision measurement of the dierence of static polarizabilities of the two clock states ∆α dc = α(5s5p 3 P 0 ) -α(5s 2 1 S 0 ) = 4.078 73(11) × 10 -39 Cm 2 /V.For this the dc Stark shift of the clock transition has been measured in the accurately known electric eld of a precision plate capacitor, which has been developed in this work.The attained static polarizability dierence ∆α dc corresponds to the rst term of a power series of the sensitivity to BBR.Higher orders are accumulated as dynamic part of the BBR shift.Which has been modelled using ∆α dc and experimental data for other atomic properties.To interrogate the ultracold atoms in the electric eld a novel transport technique has been developed, which uses the magic wavelength (813 nm) optical lattice to convey the atoms.For this, the interference pattern is translated together with the foci of the far-detuned lattice beams, by simultaneous translation of the lattice optics.In this way ultracold atoms have been transported within 250 ms over 5 cm, or several Rayleigh ranges respectively without signicant atom loss or heating.In the course of this work the rst frequency measurement with the strontium lattice clock of Physikalisch-Technischen Bundesanstalt (PTB) has been performed.The frequency of the 87 Sr clock transition was measured to be 429 228 004 229 872.9(5)Hz.The strontium lattice clock itself contributed with 1.5 × 10 -16 to the overall fractional uncertainty.Furthermore the thermal radiation eld in a cryogenic blackbody environment was modelled and a draft of a corresponding environment of the atoms was designed, which is suitable to be implemented in the strontium lattice clock of PTB.

•Jan 1, 2013•0 citations

High-Accuracy Measurement of Atomic Polarizability in an Optical Lattice Clock

Jeff A. Sherman, N. Lemke, N. Hinkley +4 more

Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels ${\ensuremath{\alpha}}_{\mathrm{clock}}=36.2612(7)\text{ }\text{ }\mathrm{kHz}\text{ }(\mathrm{kV}/\mathrm{cm}{)}^{\ensuremath{-}2}$. The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$.

arXiv:1112.2766•Physical Review Letters•Apr 13, 2012•131 citations

Scheme for Quantum-Logic Based Transfer of Accuracy in Polarizability Measurement for Trapped Ions Using a Moving Optical Lattice

Fabian Wolf

Optical atomic clocks based on trapped ions suffer from systematic frequency shifts of the clock transition due to interaction with blackbody radiation from the environment. These shifts can be compensated if the blackbody radiation spectrum and the differential dynamic polarizability is known to a sufficient precision. Here, we present a new measurement scheme, based on quantum logic that allows a direct transfer of precision for polarizability measurements from one species to the other. This measurement circumvents the necessity of calibrating laser power below the percent level, which is the limitation for state-of-the-art polarizability measurements in trapped ions. Furthermore, the presented technique allows one to reference the polarizability transfer to hydrogenlike ions for which the polarizability can be calculated with high precision.

arXiv:2308.07671•Physical Review Letters•Feb 22, 2024•6 citations

Turquoise magic wavelength of the 87 Sr clock transition

Grady Kestler, R. J. Sedlik, Elias C. Trapp +2 more

Optical lattice clocks of fermionic strontium offer a versatile platform for probing fundamental physics and developing quantum technologies. The bivalent electronic structure of strontium gives rise to a doubly forbidden atomic transition that is accessible due to hyperfine mixing in fermionic strontium-87, thus resulting in a submillihertz natural linewidth. Currently, the most accurate optical lattice clocks operate on this narrow transition by tightly trapping strontium-87 atoms in a optical lattice at 813 nm. Magic wavelengths occur where the Stark shifts of both the ground and excited states are equal, thus eliminating any position- and intensity-dependent broadening of the corresponding transition. Theoretical calculations of the electronic structure of strontium-87 have also predicted another magic wavelength of the clock transition at 497.01(57) nm. In this work, we experimentally measure the magic wavelength to be 497.4364(4) nm. Compared to the 813-nm magic wavelength, 497 nm is closer to the strong 461-nm dipolar transition of strontium, resulting in an order-of-magnitude increase in atomic polarizability and deeper traps with less optical power. The proximity to the 461-nm transition also leads to an enhanced sensitivity of 334(10) Hz/(nm E R ) at the magic wavelength.

arXiv:2506.18958•Physical Review Applied•Dec 22, 2025•0 citations

Magic Wavelength Measurement of the 87 Sr Optical Lattice Clock at NIM

Qiang Wang, Yige Lin, Fei Meng +5 more

We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.

Chinese Physics Letters•Oct 1, 2016•9 citations

Optical lattice clock on bosonic Strontium atoms

N. Poli, Marco G. Tarallo, M. Schioppo +4 more

We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•1 citation
A modification to a successfull technique to measure static differential polarizabilities of ultracold atoms and molecules is presented. Ultracold atoms are trapped in a magic wavelength optical lattice and transported into the field of a precision capacitor. The change of the transition frequency induced by the applied field, which is controlled to better than 10-4, is measured. For atomic clocks, the difference of the static polarizabilies of ground and excited state is closely related to their response to a blackbody radiation field, which is a significant contribution to the uncertainty budget of many atomic clocks.
Optical clocks have the potential to be 100 times more accurate than current best cesium atomic clocks within a fraction of the averaging time.This corresponds to a fractional uncertainty of the clock frequency on the level of 10 -18 and requires highaccuracy knowledge of systematic frequency shifts, such that they can be avoided or corrected for.In strontium optical lattice clocks an ensemble of ultracold strontium atoms is conned in an optical lattice, to allow for spectroscopy of the reference transition 5s 2 1 S 0 5s5p 3 P 0 in the Lamb-Dicke regime.The by far largest systematic frequency shift of the strontium clock transition is caused by its high sensitivity to blackbody radiation (BBR).The knowledge of the resulting frequency shift limited the achievable clock uncertainty to about 1 × 10 -16 .In this thesis for the rst time an experimental approach was followed, to determine the sensitivity of the strontium clock transition to blackbody radiation.At an environmental temperature of 300 K the resulting frequency shift corresponds to 2.277 8(23) Hz.The achieved uncertainty contributes with 5 × 10 -18 to the fractional systematic uncertainty of the clock frequency.The determination is based on a precision measurement of the dierence of static polarizabilities of the two clock states ∆α dc = α(5s5p 3 P 0 ) -α(5s 2 1 S 0 ) = 4.078 73(11) × 10 -39 Cm 2 /V.For this the dc Stark shift of the clock transition has been measured in the accurately known electric eld of a precision plate capacitor, which has been developed in this work.The attained static polarizability dierence ∆α dc corresponds to the rst term of a power series of the sensitivity to BBR.Higher orders are accumulated as dynamic part of the BBR shift.Which has been modelled using ∆α dc and experimental data for other atomic properties.To interrogate the ultracold atoms in the electric eld a novel transport technique has been developed, which uses the magic wavelength (813 nm) optical lattice to convey the atoms.For this, the interference pattern is translated together with the foci of the far-detuned lattice beams, by simultaneous translation of the lattice optics.In this way ultracold atoms have been transported within 250 ms over 5 cm, or several Rayleigh ranges respectively without signicant atom loss or heating.In the course of this work the rst frequency measurement with the strontium lattice clock of Physikalisch-Technischen Bundesanstalt (PTB) has been performed.The frequency of the 87 Sr clock transition was measured to be 429 228 004 229 872.9(5)Hz.The strontium lattice clock itself contributed with 1.5 × 10 -16 to the overall fractional uncertainty.Furthermore the thermal radiation eld in a cryogenic blackbody environment was modelled and a draft of a corresponding environment of the atoms was designed, which is suitable to be implemented in the strontium lattice clock of PTB.
Presently, the Stark effect contributes the largest source of uncertainty in a ytterbium optical atomic clock through blackbody radiation. By employing an ultracold, trapped atomic ensemble and high stability optical clock, we characterize the quadratic Stark effect with unprecedented precision. We report the ytterbium optical clock's sensitivity to electric fields (such as blackbody radiation) as the differential static polarizability of the ground and excited clock levels ${\ensuremath{\alpha}}_{\mathrm{clock}}=36.2612(7)\text{ }\text{ }\mathrm{kHz}\text{ }(\mathrm{kV}/\mathrm{cm}{)}^{\ensuremath{-}2}$. The clock's uncertainty due to room temperature blackbody radiation is reduced by an order of magnitude to $3\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$.
Optical atomic clocks based on trapped ions suffer from systematic frequency shifts of the clock transition due to interaction with blackbody radiation from the environment. These shifts can be compensated if the blackbody radiation spectrum and the differential dynamic polarizability is known to a sufficient precision. Here, we present a new measurement scheme, based on quantum logic that allows a direct transfer of precision for polarizability measurements from one species to the other. This measurement circumvents the necessity of calibrating laser power below the percent level, which is the limitation for state-of-the-art polarizability measurements in trapped ions. Furthermore, the presented technique allows one to reference the polarizability transfer to hydrogenlike ions for which the polarizability can be calculated with high precision.
Optical lattice clocks of fermionic strontium offer a versatile platform for probing fundamental physics and developing quantum technologies. The bivalent electronic structure of strontium gives rise to a doubly forbidden atomic transition that is accessible due to hyperfine mixing in fermionic strontium-87, thus resulting in a submillihertz natural linewidth. Currently, the most accurate optical lattice clocks operate on this narrow transition by tightly trapping strontium-87 atoms in a optical lattice at 813 nm. Magic wavelengths occur where the Stark shifts of both the ground and excited states are equal, thus eliminating any position- and intensity-dependent broadening of the corresponding transition. Theoretical calculations of the electronic structure of strontium-87 have also predicted another magic wavelength of the clock transition at 497.01(57) nm. In this work, we experimentally measure the magic wavelength to be 497.4364(4) nm. Compared to the 813-nm magic wavelength, 497 nm is closer to the strong 461-nm dipolar transition of strontium, resulting in an order-of-magnitude increase in atomic polarizability and deeper traps with less optical power. The proximity to the 461-nm transition also leads to an enhanced sensitivity of 334(10) Hz/(nm E R ) at the magic wavelength.
We report on the magic wavelength measurement of our optical lattice clock based on fermion strontium atoms at the National Institute of Metrology (NIM). A Ti:sapphire solid state laser locked to a reference cavity inside a temperature-stabilized vacuum chamber is employed to generate the optical lattice. The laser frequency is measured by an erbium fiber frequency comb. The trap depth is modulated by varying the lattice laser power via an acousto-optic modulator. We obtain the frequency shift coefficient at this lattice wavelength by measuring the differential frequency shift of the clock transition of the strontium atoms at different trap depths, and the frequency shift coefficient at this lattice wavelength is obtained. We measure the frequency shift coefficients at different lattice frequencies around the magic wavelength and linearly fit the measurement data, and the magic wavelength is calculated to be 368554672(44) MHz.
We report on recent realization of an optical lattice clock operating on the1S0-3P0transition in88Sr, at LENS laboratories. The clock transition is excited with the technique of magnetic field-induced spectroscopy. New experimental techniques has also been developed in order to simplifies the clock spectroscopy in Sr atoms. The first new method helps in the first search of the clock transition without the use of extensive frequency metrology hardware and in particular optical frequency combs. This technique exploits a near coincidence in the atomic wavelengths of the1S0-3P0clock and1S0-3P1second stage cooling transitions in Sr, which are only 5 THz far apart. This coincidence enables the use of an optical (transfer) cavity to reference the frequency of the clock transition relative to that of the much stronger cooling transition. Secondly we reduce the complexity of the experimental setup by using only semiconductor laser sources in the apparatus. With this setup, about 10488Sr atoms are trapped in a 1D lattice formed by 200 mW of radiation tuned near the magic wavelength at 813 nm. We will present a first uncertainty budget for our optical lattice clock based on88Sr with particular attention to density dependent collisions, which led to an unexpectedly high signal contrast for long interaction times. In view of an absolute frequency measurement of clock transition we'll also present recent experimental results on optimization of an home made Ti:Sa optical frequency comb. Additionally, we anticipate that the simplification of the experimental setup presented will help address a wider range of applications including those requiring transportable devices. Along these lines we will report progress on the realization of the first transportable Sr optical lattice clock.