Analog simulations of the three-photon Josephson parametric amplifier indicate that the noise rise observed in experimental devices arises from occasional hopping between a mode at the pump frequency ωP and a mode at the half-harmonic ωP/2 . The hopping is induced by thermal noise associated with the shunt resistance.
We are engaged in an experimental effort to generate and detect squeezed vacuum fluctuations at microwave frequencies using a Josephson parametric amplifier. We have demonstrated 42% deamplification of 4.2-K thermal noise at 19.4 GHz. At this frequency the vacuum fluctuation noise is an order of magnitude smaller than 4.2-K thermal noise. We have installed cryogenic HEMT amplifiers in our apparatus, thereby increasing the detector sensitivity by an order of magnitude. Josephson parametric amplifiers have been notorious for exhibiting excess noise whose origin is still controversial. We have performed a systematic study of the noise performance of our device both below and above threshold in a variety of modes of operation. The experiments indicate that the excess noise in our device arises from low-frequency noise (0-20 MHz) propagating down dc bias lines. When an intense coherent oscillation is present in the signal passband, such as the pump when the amplifier is in the four-photon mode or the period doubled oscillations when the amplifier is operated in the three-photon mode above threshold, the low- frequency noise mixes with the coherent oscillation to generate noise sidebands in the amplifier's passband. Nevertheless, in suitable conditions, extremely low noise and high gains were achieved.
We take a new look at an old problem; namely, the observed ‘‘noise rise’’ in superconducting Josephson junction parametric amplifiers. By exploiting recent insights from dynamical systems theory, we show how the interplay or random noise and (nonchaotic) deterministic dynamics can result in a noise rise like that observed in experiments. Our analysis leads to a universal first-order equation which applies to all similar systems in the high-gain regime. We propose several predictions which can be tested experimentally, including that a similar noise rise should occur in modulated semiconductor injection lasers. We also analyze a previously unknown mode of operation—a ‘‘six-photon’’ mode associated with a symmetry breaking bifurcation—and discuss its potential advantages over the previously studied three- and four-photon modes.
We present the results of an experimental effort to generate squeezed microwave radiation using the phase-sensitive gain of a Josephson parametric amplifier. To facilitate the interpretation of the experimental results, we first present a discussion of the theory of microwave squeezing via Josephson parametric amplifiers. This is followed by a detailed description of the device fabricated for our experiment. Experimental results are then presented for the device used in both the doubly degenerate or four-photon mode and for the degenerate or three-photon mode. We have observed parametric deamplification of signals by more than 8 dB. We have demonstrated squeezing of 4.2-K thermal noise. When operated at 0.1 K, the amplifier exhibits an excess noise of 0.28 K when referred to the input. This is smaller than the vacuum fluctuation noise level \ensuremath{\Elzxh}\ensuremath{\omega}/2k=0.47 K. The amplifier is thus quieter than a linear phase-insensitive amplifier in principle can be.
The high-frequency amplification properties of transformer coupled, resistively shunted Josephson tunnel junctions have been investigated. The importance of the shunt loop inductance is stressed. It allows a high cutoff frequency, of significance for good high-frequency performance. The self-pumped parametric amplifier showed none of the excessive noise rise, which has hitherto plagued the development of externally pumped Josephson junction amplifiers. Around 10 GHz, we estimated a noise temperature less than 30 K for an amplifier pumped by a Josephson oscillation with a frequency well above twice the signal frequency. The corresponding gain of 5 dB may be increased in a better impedance matched circuit. The gain was very stable against variations in the bias conditions. A gain-bandwidth product as high as 0.3 was registered. The experimental results agreed well with the established theory for self-pumped parametric Josephson amplifiers. It should be possible to extend the low noise amplification by this device to mm wave frequencies. A relaxation oscillation occurred at a subharmonic of the Josephson frequency when the shunt loop inductance became large. The amplification in this mode followed closely the predictions of a simple model, where the signal modulated the switching of the sawtooth-like (relatively low frequency) relaxation current. Gains of about 15 dB were measured around 10 GHz, but the amplification was sensitive to bias conditions and noisy in this case where the relaxation frequency fell well below the signal frequency. Much improved properties were registered when the inductance was decreased so that the relaxation frequency approached the Josephson frequency and exceeded twice the signal frequency. The behavior then resembled that of a Josephson mode parametric amplifier, but the high content of harmonics of a relaxation oscillation meant that the amplifier became noisier due to converted noise from the many idler frequencies.
We describe a novel noise mechanism which should effect all externally pumped parametric amplifiers. The theory is developed specifically for the four-wave Josephson paramp. We predict a noise temperature rising in direct proportion to the amplifier gain; this prediction agrees perfectly with all previously published data for both the three- and four- wave Josephson amplifiers. An explicit expression for the noise temperature of the four-wave device is derived and compared to previous experiments.
Crossover between thermal and quantum noise in the externally-pumped Josephson-junction parametric amplifiers is theoretically followed. Two different approaches are used for the analysis : i. Josephson junction is replaced with its RSJ model with the equilibrium source of fluctuations; ii. microscopic theory of the tunnel junctions is used, which takes into account not only thermal and quantum but also shot noise. Because of inconvenience of the noise temperature TNfor the amplifier sensitivity characterization in the quantum limit, we express our results in terms of the figure ΘNwhich is essentially the amplifier output noise energy, reduced to its input (in the classical limit,\Theta_{N}=k_{B}T_{N}). For the nondegenerate amplifier, the minimum value of ΘN. equals hω/2 and is due to quantum noise (zero-point oscillations) in the idle-frequency resonator of the amplifier. For the degenerate amplifier, sensitive to only one quadrature component of the input signal, ΘNcan be made much less than the above "quantum limit" even at operation temperatures much higher thanh\omega/k_{B}, if the Josephson junction characteristic frequency ωcis high enough,h\omega_{c}\gsimk_{B}T. Our analysis of the experimental situatlon shows that the values\Theta_{N}<h\omega/2can be achieved using two-dimensional arrays of a large number (N\simeq100) single-tunnel-junction interferometers with low inductances, inductively coupled to a microwave cavity.