Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Zeitschrift für Physik D Atoms Molecules and Clusters

Lifetime Measurement of the 33 P state of helium

H A Silim, Ali H. El-Farrash, Hans Kleinpoppen

Published Mar 1, 1987• 8 citations
Publisher
DOI
10.1007/bf01436575

Related papers

Effects of impurity molecules on the lifetime of antiprotonic helium atoms

Bertalan Juhász, J. A. Eades, R. Hayano +7 more

Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms•Jul 31, 2003•1 citation

The Temperature Dependence and Pressure Dependence of the Lifetime of Singlet Metastable Helium.

John Clement Hungerman

•Jan 1, 1972•0 citations

Radiative Lifetime of the Metastable 2S01 State of Helium

Robert S. Van Dyck, C. E. Johnson, Howard A. Shugart

Two fixed, spatially separated detectors are used to measure the decay in flight of a cooled, thermal beam of pulsed metastable helium atoms. The preliminary value obtained for the radiative lifetime of the metastable $2^{1}S_{0}$ state of helium is 20 \ifmmode\pm\else\textpm\fi{} 2 msec.

Physical Review Letters•Nov 16, 1970•38 citations

Long-Range Interaction between Metastable Helium and Ground State Helium

G. A. Victor, Kenneth M. Sando

The Journal of Chemical Physics•Dec 1, 1971•25 citations

Half-Life of Metastable Helium Atoms.

Jesse Truett Matthews

•Jan 1, 1960•0 citations

Laser spectroscopic studies of state-dependent collisional quenching of the lifetimes of metastable antiprotonic helium atoms

M. Hori, H. A. Torii, R. Hayano +16 more

A laser spectroscopic method was developed to directly observe the lifetimes of individual states in metastable antiprotonic helium atoms $(\overline{p}{}^{4}{\mathrm{He}}^{+}).$ Collisional effects with surrounding helium atoms were studied in cryogenic gas targets at pressures between 0.1 and 9.0 bars and at temperatures between 5.5 and 7.0 K. The metastable state $(n,\mathcal{l})=(39,35)$ showed a lifetime of 1.5 $\ensuremath{\mu}\mathrm{s}$, regardless of density, whereas the lifetime of the energetically lower-lying state $(37,34)$ was found to shorten from 1.3 to 0.1 $\ensuremath{\mu}$s with increasing density. The lifetimes of the states $(38,34)$ and $(36,33)$ were determined to be 10 ns and 5 ns, respectively, showing the effects of the internal Auger process. When extrapolated to zero density, the measured lifetimes agreed with the results of calculations for the radiative and Auger widths. Using the fact that the state $(37,34)$ becomes short lived at high density, the resonance $(38,35)\ensuremath{\rightarrow}(37,34)$ at 529.62 nm was detected.

Physical Review A•Mar 1, 1998•43 citations
Two fixed, spatially separated detectors are used to measure the decay in flight of a cooled, thermal beam of pulsed metastable helium atoms. The preliminary value obtained for the radiative lifetime of the metastable 21S02^{1}S_{0}21S0​ state of helium is 20 \ifmmode\pm\else\textpm\fi{} 2 msec.
A laser spectroscopic method was developed to directly observe the lifetimes of individual states in metastable antiprotonic helium atoms (p‾4He+).(\overline{p}{}^{4}{\mathrm{He}}^{+}).(p​4He+). Collisional effects with surrounding helium atoms were studied in cryogenic gas targets at pressures between 0.1 and 9.0 bars and at temperatures between 5.5 and 7.0 K. The metastable state (n,l)=(39,35)(n,\mathcal{l})=(39,35)(n,l)=(39,35) showed a lifetime of 1.5 $\ensuremath{\mu}\mathrm{s}$, regardless of density, whereas the lifetime of the energetically lower-lying state (37,34)(37,34)(37,34) was found to shorten from 1.3 to 0.1 $\ensuremath{\mu}$s with increasing density. The lifetimes of the states (38,34)(38,34)(38,34) and (36,33)(36,33)(36,33) were determined to be 10 ns and 5 ns, respectively, showing the effects of the internal Auger process. When extrapolated to zero density, the measured lifetimes agreed with the results of calculations for the radiative and Auger widths. Using the fact that the state (37,34)(37,34)(37,34) becomes short lived at high density, the resonance $(38,35)\ensuremath{\rightarrow}(37,34)$ at 529.62 nm was detected.