Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Pacific Rim (CLEO-PR)

High-resolution quantum optical coherence tomography by broadband parametric fluorescence

Masayuki Okano, Ryo Okamoto, Akira Tanaka, Shutaro Ishida, Norihiko Nishizawa, Shigeki Takeuchi

Published Jun 1, 2013• 1 citation
Publisher

Abstract

Quantum optical coherence tomography (QOCT) can achieve high-resolution imaging with dispersion tolerance by virtue of quantum entanglement. We demonstrate advantages of high-resolution QOCT by comparison with classical optical coherence tomography.
DOI
10.1109/cleopr.2013.6600600

Related papers

Ultrabroadband spontaneous parametric fluorescence in 800 nm region toward ultrahigh-resolution quantum optical coherence tomography

Masayuki Okano, Hwan Hong Lim, Ryo Okamoto +5 more

Quantum optical coherence tomography can realize high-resolution imaging with dispersion tolerance by virtue of quantum entanglement. We generate ultrabroadband spontaneous parametric fluorescence from chirped quasi-phase matching devices to achieve the ultrahigh-resolution imaging.

Frontiers in Optics•Jan 1, 2014•1 citation

High-depth-resolution imaging of dispersive samples using quantum optical coherence tomography

Kyohei Hayama, Bo Cao, Ryo Okamoto +3 more

Quantum optical coherence tomography (QOCT) is a promising approach to overcome the degradation of the resolution in optical coherence tomography (OCT) due to dispersion. Here, we report on an experimental demonstration of QOCT imaging in the high-resolution regime. We achieved a depth resolution of 2.5 μ m, which is the highest value for QOCT imaging, to the best of our knowledge. We show that the QOCT image of a dispersive material remains clear whereas the OCT image is drastically degraded.

Optics Letters•Aug 29, 2022•24 citations

Broadband spontaneous parametric fluorescence toward high-resolution quantum optical coherence tomography

Masayuki Okano, Ryo Okamoto, Akira Tanaka +4 more

To realize high-resolution quantum optical coherence tomography, we have generated broadband spontaneous parametric fluorescence from two nonlinear crystals. Measured bandwidth (~170 nm) can lead to sub-micron axial resolution. For comparison, we have demonstrated optical coherence tomography using the super luminescence diode with the bandwidth of 77 nm and measured axial resolution was approximately 5 μm.

International Conference on Quantum Information•Jan 1, 2011•0 citations

Cross-correlation scheme for quantum optical coherence tomography based on Michelson interferometer

Anna Romanova, Vadim Rodimin, Konstantin Katamadze

Quantum optical coherence tomography (QOCT) offers a simple way to cancel dispersion broadening in a sample while also providing twice the resolution compared to classical OCT. However, to achieve these advantages, a bright and broadband source of entangled photon pairs is required. A simple implementation uses collinear spontaneous parametric down-conversion in a Michelson interferometer (MI), yet this autocorrelation scheme suffers from parasitic terms and sensitivity to phase noise. Here, we introduce a cross-correlation MI-based QOCT that overcomes these drawbacks, significantly advancing QOCT toward practical applications.

arXiv:2505.08095•Physical Review Applied•Nov 24, 2025•1 citation

Multi-reflection quantum-optical coherence tomography and experimental mimic with the classical optical field

Qian Li, Yifan Sun, Ling‐Jun Kong +1 more

Quantum optical coherence tomography (QOCT) is the non-classical counterpart of optical coherence tomography (OCT), by which quantum interference of entangled photon pairs is used to show some advantages over classical OCT. Currently, almost all research on the QOCT focuses on the case with two photons and a twofold improvement in axial resolution has been demonstrated. Here, we introduce the multiple reflections strategy into the QOCT scheme, referencing the multi-pass strategy of the sequential scheme in quantum metrology, and provide a theoretical framework for multi-reflection quantum-optical coherence tomography (MQOCT). According to such a scheme, when the incident light interacts with the sample N times, the axial resolution of MQOCT is theoretically enhanced by a factor of N compared to that of QOCT under the same spectral bandwidth while preserving the dispersion cancellation capability of QOCT. Furthermore, we present a classical optical analogy of MQOCT using P -beam correlated multi-mode broadband beams and experimentally validate it. The classical optical analogy of MQOCT theoretically has the same resolution enhancement capability and dispersion cancellation capability as MQOCT while avoiding the fragility issues associated with the quantum light source which is used in MQOCT.

Optics Express•Feb 13, 2025•0 citations

Generation of broadband spontaneous parametric fluorescence and its application to quantum optical coherence tomography

Masayuki Okano, Ryo Okamoto, Akira Tanaka +4 more

Optical coherence tomography (OCT) based on Michelson interferometer has widely been utilized in biology and medicine as a type of optical biopsy and quantum optical coherence tomography (QOCT) based on Hong-Ou-Mandel interferometer has recently been demonstrated. By use of quantum entangled photon pairs generated via spontaneous parametric down conversion (SPDC) process, axial resolution of QOCT can be better than that of OCT in principle for a source of same bandwidth and group velocity dispersion (GVD) effect for QOCT can be automatically cancelled thanks to the frequency correlation of entangled photon pairs. To realize high-resolution QOCT, we need a broadband quantum entangled photon pair source. Then we proposed a novel conventional method to generate broadband spontaneous parametric fluorescence via SPDC by using multiple nonlinear crystals pumped by a CW laser. Our method has controllability to tune the center frequency of generated photons and scalability to extend the number of crystals. This conventional method can enable us to achieve sub-micron axial resolution of QOCT.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 1, 2011•0 citations
Quantum optical coherence tomography (QOCT) offers a simple way to cancel dispersion broadening in a sample while also providing twice the resolution compared to classical OCT. However, to achieve these advantages, a bright and broadband source of entangled photon pairs is required. A simple implementation uses collinear spontaneous parametric down-conversion in a Michelson interferometer (MI), yet this autocorrelation scheme suffers from parasitic terms and sensitivity to phase noise. Here, we introduce a cross-correlation MI-based QOCT that overcomes these drawbacks, significantly advancing QOCT toward practical applications.
Quantum optical coherence tomography (QOCT) is the non-classical counterpart of optical coherence tomography (OCT), by which quantum interference of entangled photon pairs is used to show some advantages over classical OCT. Currently, almost all research on the QOCT focuses on the case with two photons and a twofold improvement in axial resolution has been demonstrated. Here, we introduce the multiple reflections strategy into the QOCT scheme, referencing the multi-pass strategy of the sequential scheme in quantum metrology, and provide a theoretical framework for multi-reflection quantum-optical coherence tomography (MQOCT). According to such a scheme, when the incident light interacts with the sample N times, the axial resolution of MQOCT is theoretically enhanced by a factor of N compared to that of QOCT under the same spectral bandwidth while preserving the dispersion cancellation capability of QOCT. Furthermore, we present a classical optical analogy of MQOCT using P -beam correlated multi-mode broadband beams and experimentally validate it. The classical optical analogy of MQOCT theoretically has the same resolution enhancement capability and dispersion cancellation capability as MQOCT while avoiding the fragility issues associated with the quantum light source which is used in MQOCT.
Optical coherence tomography (OCT) based on Michelson interferometer has widely been utilized in biology and medicine as a type of optical biopsy and quantum optical coherence tomography (QOCT) based on Hong-Ou-Mandel interferometer has recently been demonstrated. By use of quantum entangled photon pairs generated via spontaneous parametric down conversion (SPDC) process, axial resolution of QOCT can be better than that of OCT in principle for a source of same bandwidth and group velocity dispersion (GVD) effect for QOCT can be automatically cancelled thanks to the frequency correlation of entangled photon pairs. To realize high-resolution QOCT, we need a broadband quantum entangled photon pair source. Then we proposed a novel conventional method to generate broadband spontaneous parametric fluorescence via SPDC by using multiple nonlinear crystals pumped by a CW laser. Our method has controllability to tune the center frequency of generated photons and scalability to extend the number of crystals. This conventional method can enable us to achieve sub-micron axial resolution of QOCT.