Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Luminescence

Spectral hole burning and Raman heterodyne signals associated with an avoided crossing in the NV centre in diamond

J. P. D. Martin, Neil B. Manson, David C. Doetschman, Matthew J. Sellars, Rudolf Neuhaus, E. Wilson

Published Apr 1, 2000• 14 citations
Publisher
DOI
10.1016/s0022-2313(00)00179-4

Related papers

Hole burning—EIT studies of the NV centre in diamond

Neil B. Manson, Lachlan J. Rogers, E.A. Wilson +1 more

Journal of Luminescence•Mar 11, 2010•13 citations

Two-laser spectral hole burning in a colour centre in diamond

N. R. S. Reddy, N. B. Manson, Elmars Krausz

Journal of Luminescence•Dec 1, 1987•159 citations

Raman heterodyne studies of the nitrogen-vacancy centre in diamond

Neil B. Manson, Xing-Fei He, Peter Fisk

Journal of Luminescence•Jul 1, 1992•15 citations

NV centers in diamond: spin-selective photokinetics, optical ground-state spin alignment and hole burning

Alexander P. Nizovtsev, S. Ya. Kilin, Fedor Jelezko +3 more

Physica B Condensed Matter•Dec 1, 2003•35 citations

Removing inhomogeneous broadening in cross-relaxation spectra via hole burning

Fei Kong, Zhehua Huang, Zhengze Zhao +4 more

Quantum relaxometry based on nitrogen-vacancy (NV) centers in diamond is an easy-to-use technique that detects magnetic noise by measuring the longitudinal relaxation of NV centers. It is favored in chemical and biological applications due to the robustness against imperfect spin control. By tuning the energy level, NV relaxometry can detect magnetic noise generated by other spins and obtain magnetic resonance spectra through cross relaxation. However, the inhomogeneous broadening of NV centers greatly limits the spectral resolution of cross-relaxation spectra. Here we demonstrate a hole-burning technique to remove the inhomogeneous broadening. We utilize a weak pump field to deplete specific NV centers during the relaxation measurement, which contribute a reverse signal in the cross-relaxation spectra with a much narrower linewidth. Our method retains the convenience and sensitivity of NV relaxometry, opening up new avenues for high-resolution magnetic resonance spectroscopy in complex scenarios.

quant-pharXiv:2607.16839•Jul 21, 2026

Transient hole burning in N-V centre in diamond

Neil B. Manson, C. Wei

Journal of Luminescence•Jan 1, 1994•20 citations
Quantum relaxometry based on nitrogen-vacancy (NV) centers in diamond is an easy-to-use technique that detects magnetic noise by measuring the longitudinal relaxation of NV centers. It is favored in chemical and biological applications due to the robustness against imperfect spin control. By tuning the energy level, NV relaxometry can detect magnetic noise generated by other spins and obtain magnetic resonance spectra through cross relaxation. However, the inhomogeneous broadening of NV centers greatly limits the spectral resolution of cross-relaxation spectra. Here we demonstrate a hole-burning technique to remove the inhomogeneous broadening. We utilize a weak pump field to deplete specific NV centers during the relaxation measurement, which contribute a reverse signal in the cross-relaxation spectra with a much narrower linewidth. Our method retains the convenience and sensitivity of NV relaxometry, opening up new avenues for high-resolution magnetic resonance spectroscopy in complex scenarios.