Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Observation of Ramsey fringes in nonlinear Faraday rotation

B. Schuh, S. I. Kanorsky, Antoine Weis, Theodor W. Hänsch

Published Jul 1, 1993• 35 citations
Publisher
DOI
10.1016/0030-4018(93)90243-x

Related papers

Nonlinear Faraday rotation in samarium vapor

Lev M Barkov, D. A. Melik-Pashaev, Max S. Zolotorev

Optics Communications•Apr 1, 1989•64 citations

Ramseyfication of the Resonant Nonlinear Faraday Effect

Antoine Weis

Springer eBooks•Jan 1, 2002•1 citation

Observation of Faraday Rotation in Cold Atoms in an Integrating Sphere

Ben-Chang Zheng, Hua-Dong Cheng, Yan-Ling Meng +3 more

The Faraday rotation of weak linearly polarized probe light is observed as it passes through a sample of cold 87 Rb atoms prepared by diffused light in an integrating sphere. The rotation angle of the probe light-polarization as functions of laser intensity, detuning and biased magnetic field is measured. A Ramsey fringe with a linewidth of 35 Hz and contrast up to 92% is demonstrated. This method has potential applications in improving the performance of atomic clocks with cold atoms.

Chinese Physics Letters•Jul 1, 2014•1 citation

Pulsed vapor cell atomic clock with a differential Faraday rotation angle detection

Kemu Wang, Zhijing Du, Yanyan Liu +5 more

Laser intensity noise is one of the main limiting factors in pulsed vapor cell clocks. To reduce the contribution of the laser intensity noise to detection signal in the pulsed optically pumped atomic clock, a scheme based on the differential Faraday rotation angle is proposed. Theoretically, the Ramsey fringes, the sensitivity of clock frequency to laser intensity fluctuation and the signal to noise ratio for absorption, differential, and Faraday rotation angle methods are calculated and compared. Using a Wollaston prism rotated 45°relative to the incident polarization, and two photodetectors, Ramsey fringes of three detection methods are obtained simultaneously. In the proposed scheme, the long-term Faraday rotation angle fluctuation is 0.66% at 30000s, which is much smaller than fluctuation of traditional absorption signal 3.9% at 30000s. And the contribution of laser intensity noise to clock instability is also reduced. Using optimized photodetector with high common mode rejection ratio, a better performance should be expected. This proposed scheme is attractive for the development of high performance vapor clock based on pulsed optically pumped.

Optics Express•Oct 28, 2021•5 citations

Recoil-Induced Optical Faraday Rotation

B. Dubetsky, P. R. Berman

Springer eBooks•Jan 1, 1996•1 citation

Faraday–Ramsey Rotation in Ultrathin Alkali Vapor Cells as an Analogy to Atomic‐Beam Systems

Mark Dikopoltsev, Eliran Talker, Yefim Barash +2 more

ABSTRACT Atomic beams are powerful tools for measuring fundamental physical constants, probing atomic interactions, and developing precision metrology techniques such as atomic clocks and interferometry. However, most atomic‐beam devices are bulky, which limits their miniaturization. Recent efforts toward the miniaturization of atomic beams have been reported (see, Ref. [10]). Here, we demonstrate an alternative approach, showing that micrometer‐scale vapor cells can emulate atomic‐beam behavior through geometry‐dependent velocity filtering. Specifically, in a 5‐µm‐thick rubidium vapor cell, coherence is preserved for atoms moving parallel to the cell walls, enabling observation of the Faraday–Ramsey effect in the absence of buffer gas or anti‐relaxation coatings. Using a spatially displaced pump–probe scheme and magnetic‐field scanning, we observe distinct Ramsey fringes in excellent agreement with the theoretical model. This technique enables compact implementations of Faraday–Ramsey measurements in microfabricated alkali‐vapor cells.

Laser & Photonics Review•Jan 7, 2026•1 citation
Laser intensity noise is one of the main limiting factors in pulsed vapor cell clocks. To reduce the contribution of the laser intensity noise to detection signal in the pulsed optically pumped atomic clock, a scheme based on the differential Faraday rotation angle is proposed. Theoretically, the Ramsey fringes, the sensitivity of clock frequency to laser intensity fluctuation and the signal to noise ratio for absorption, differential, and Faraday rotation angle methods are calculated and compared. Using a Wollaston prism rotated 45°relative to the incident polarization, and two photodetectors, Ramsey fringes of three detection methods are obtained simultaneously. In the proposed scheme, the long-term Faraday rotation angle fluctuation is 0.66% at 30000s, which is much smaller than fluctuation of traditional absorption signal 3.9% at 30000s. And the contribution of laser intensity noise to clock instability is also reduced. Using optimized photodetector with high common mode rejection ratio, a better performance should be expected. This proposed scheme is attractive for the development of high performance vapor clock based on pulsed optically pumped.
ABSTRACT Atomic beams are powerful tools for measuring fundamental physical constants, probing atomic interactions, and developing precision metrology techniques such as atomic clocks and interferometry. However, most atomic‐beam devices are bulky, which limits their miniaturization. Recent efforts toward the miniaturization of atomic beams have been reported (see, Ref. [10]). Here, we demonstrate an alternative approach, showing that micrometer‐scale vapor cells can emulate atomic‐beam behavior through geometry‐dependent velocity filtering. Specifically, in a 5‐µm‐thick rubidium vapor cell, coherence is preserved for atoms moving parallel to the cell walls, enabling observation of the Faraday–Ramsey effect in the absence of buffer gas or anti‐relaxation coatings. Using a spatially displaced pump–probe scheme and magnetic‐field scanning, we observe distinct Ramsey fringes in excellent agreement with the theoretical model. This technique enables compact implementations of Faraday–Ramsey measurements in microfabricated alkali‐vapor cells.