Sensors and Actuators A Physical

Design of a superconducting bolometer for low-power standards in the millimetre wave field

Domenico Andreone, L. Brunetti, M. Petrizzelli

Published Apr 1, 1994• 2 citations
Publisher
DOI
10.1016/0924-4247(94)80098-7

Related papers

Superconducting Millimetre-Wavelength Bolometers

J.C. Macfarlane, W. Wright, STEPHEN W. FILIPCZUK +4 more

Asia-Pacific Microwave Conference (APMC)•Aug 24, 2005•0 citations

Continuous-Wave Noise Equivalent Power and Minimum Pulse Power Detectable by a Superconducting Terahertz Bolometer

T. I. Novikova, K. Shein, Sergey V. Seliverstov +2 more

Journal of Infrared Millimeter and Terahertz Waves•Oct 1, 2026•0 citations

The design and instrumentation of a superconducting bolometer

Jerald Ray Hyde

•Jan 1, 2015•0 citations

Gain-Bandwidth Characteristics of High-Tc Superconducting Millimeter-Wave Hot-Electron Bolometer Mixers

Chao-Te Li, Bascom S. Deaver, Robert M. Weikle +3 more

The conversion gain bandwidth characteristics of millimeter-wave mixers using high-Tc superconducting YBa2Cu307 (YBCO) thin films are presented. The YBCO films are patterned into latticecooled hot-electron bolometers (HEB) coupled to an integrated antenna and transmission line. Direct heterodyne and homodyne down-conversion measurements using local-oscillator frequencies of 75 GHz and 585 GHz show overall conversion gains of -35 dB, which includes a -18 dB coupling loss. The gain bandwidth shows a simple Lorentzian roll-off with -3 dB point of 5 to 8 GHz. No second plateau in the gain spectrum has been observed, in contrast to other reports. The effective volume of the HEB is believed to be significantly smaller than the physical dimensions of the device. Gershenzon, et al. 1 first proposed the design of a lattice-cooled superconducting hot-electron bolometer (HEB) for use as a low-power, wide-band-width heterodyne mixer at millimeter and submillimeter-wave frequencies. This idea has been successfully implemented using NbN , which shows a conversion gain as high as -15 dB using 1 1.tW of pump power at a temperature of 4.2 K. The ultimate speed and bandwidth of the lattice-cooled HEB is determined by the electron-phonon scattering rate. For this reason, Gershenzon 3 suggested that the high normal-state resistivity of the high-Tc superconductor YBa2Cu307 (YBCO) could indicate a very fast electron inelastic scattering, rate and so make this material an ideal candidate to produce a very wide instantaneous bandwidth lattice-cooled HEB operating at 77 K. The first reports of such mixers at 1.5 gm (Ref. 4) and 9.6 gm (Ref. 5) wavelengths showed a very low intrinsic conversion gain of -77 dB (excluding coupling losses) using a relatively large 0.3 mW of absorbed LO power. However, the gain bandwidth showed a twoplateau structure. A low frequency plateau near -77 dB rolled off near 1 GHz intermediate frequency (IF) but gave way to a second plateau near -90 dB that extended to at least 18 GHz, the upper limit of the measurement. Karasik, et al., have done extensive calculations on the conversion gain properties of lattice-cooled HEB mixers for different mixer dimensions, using a two-temperature model. They found that the conversion gain increases

•Mar 1, 1998•1 citation

Investigation of the low-frequency noise of a superconducting bolometer

Г. А. Зайцев, I. A. Khrebtov

RaEl•May 1, 1978•0 citations

Low-noise readout of superconducting bolometers based on electrothermal feedback

Jari S Penttilä, Hannu Sipola, P. Helistö +1 more

We have developed a simple room-temperature readout for superconducting bolometers and calorimeters. Due to electro-thermal feedback, the bolometer can be noise-matched with the readout amplifier. The constructed amplifier consists of low-noise field-effect transistors, and voltage bias is actively provided by electrical feedback. According to our measurements on superconducting vacuum-bridge bolometers, the total noise is limited by the bolometer phonon and Johnson noise characterized by a critical temperature of 8.5 K. We show that, with proper sensor design, it is possible to reach the photon noise limit in video-rate submillimetre imaging applications.

Superconductor Science and Technology•Feb 13, 2006•30 citations
The conversion gain bandwidth characteristics of millimeter-wave mixers using high-Tc superconducting YBa2Cu307 (YBCO) thin films are presented. The YBCO films are patterned into latticecooled hot-electron bolometers (HEB) coupled to an integrated antenna and transmission line. Direct heterodyne and homodyne down-conversion measurements using local-oscillator frequencies of 75 GHz and 585 GHz show overall conversion gains of -35 dB, which includes a -18 dB coupling loss. The gain bandwidth shows a simple Lorentzian roll-off with -3 dB point of 5 to 8 GHz. No second plateau in the gain spectrum has been observed, in contrast to other reports. The effective volume of the HEB is believed to be significantly smaller than the physical dimensions of the device. Gershenzon, et al. 1 first proposed the design of a lattice-cooled superconducting hot-electron bolometer (HEB) for use as a low-power, wide-band-width heterodyne mixer at millimeter and submillimeter-wave frequencies. This idea has been successfully implemented using NbN , which shows a conversion gain as high as -15 dB using 1 1.tW of pump power at a temperature of 4.2 K. The ultimate speed and bandwidth of the lattice-cooled HEB is determined by the electron-phonon scattering rate. For this reason, Gershenzon 3 suggested that the high normal-state resistivity of the high-Tc superconductor YBa2Cu307 (YBCO) could indicate a very fast electron inelastic scattering, rate and so make this material an ideal candidate to produce a very wide instantaneous bandwidth lattice-cooled HEB operating at 77 K. The first reports of such mixers at 1.5 gm (Ref. 4) and 9.6 gm (Ref. 5) wavelengths showed a very low intrinsic conversion gain of -77 dB (excluding coupling losses) using a relatively large 0.3 mW of absorbed LO power. However, the gain bandwidth showed a twoplateau structure. A low frequency plateau near -77 dB rolled off near 1 GHz intermediate frequency (IF) but gave way to a second plateau near -90 dB that extended to at least 18 GHz, the upper limit of the measurement. Karasik, et al., have done extensive calculations on the conversion gain properties of lattice-cooled HEB mixers for different mixer dimensions, using a two-temperature model. They found that the conversion gain increases
We have developed a simple room-temperature readout for superconducting bolometers and calorimeters. Due to electro-thermal feedback, the bolometer can be noise-matched with the readout amplifier. The constructed amplifier consists of low-noise field-effect transistors, and voltage bias is actively provided by electrical feedback. According to our measurements on superconducting vacuum-bridge bolometers, the total noise is limited by the bolometer phonon and Johnson noise characterized by a critical temperature of 8.5 K. We show that, with proper sensor design, it is possible to reach the photon noise limit in video-rate submillimetre imaging applications.