Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Reduced Active Area in Transition-Edge Sensors for Visible-NIR Photon Detection: A Comparison of Experimental Data and Two-Fluid Model

E. Taralli, L. Lolli, Chiara Portesi, E. Monticone, M. Rajteri, T.-S. Wang, J.-K. Chen, Xingxiang Zhou

Published Nov 6, 2014• 5 citations
Publisher

Abstract

Transition-edge sensors (TESs) are very versatile superconducting devices used to detect radiation from gamma-rays to visible and submillimeter. The intrinsic capability to measure the energy of the absorbed photons with very high energy resolution and the related possibility to resolve the number of incident photons distinguish photon-number resolving (PNR) devices from any other photon detectors. PNR detectors are fundamental for the measurement of the photon-number distribution of singlephoton emitters and for the progress of quantum information technology and quantum metrology. By reducing the active area of TESs for visible-NIR light from typical values of 10-10m2toward 10-12m2and by increasing the TES operating temperature, we should be able to combine the high energy resolution permitted by very low heat capacity with fast response time. To support the future design and development of this new type of detector, in this work we compare experimental data with circuit simulation results based on the two-fluid theory.

DOI
10.1109/tasc.2014.2367469

Related papers

Photon-Number Resolving by Superconductive Devices

L. Lolli

Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths

•Jan 1, 2012•0 citations

Single-photon light detection with transition-edge sensors

M. Rajteri, E. Taralli, Chiara Portesi +1 more

Transition-Edge Sensors (TESs) are microcalorimeters that measure the energy of incident single photons by the resistance increase of a superconducting film biased within the superconducting-to-normal transition. TES are able to detect single photons from IR to X-ray with an intrinsic energy resolution and photon-number discrimination capability. Metrology, astronomy and quantum \ncommunication are the fields where these properties can be particularly useful. In this work, we report about characterization of different TESs based on Ti films. Single photons have been detected from 200nm to 800 nm working at transition temperature Tc ∼ 100 mK. Using a pulsed laser at 690nm we have demonstrated the capability to resolve up to five photons.

NCimC•Jul 1, 2008•2 citations

Superconducting transition-edge sensors optimized for high-efficiency photon-number resolving detectors

Adriana E. Lita, Brice Calkins, Lenson A. Pellouchoud +2 more

Superconducting photon detectors have emerged as a powerful new option for detecting single photons. System detection efficiency that incorporates the quantum efficiency of the device and system losses is one of the most important single-photon detector performance metrics for quantum information applications. Superconducting transition-edge sensors (TESs) are microcalorimeters that have the ability of distinguishing single photons with negligible dark counts. In addition, TESs are capable of directly measuring the photon number in a pulse of light. We have achieved near-unity system detection efficiency with TESs at particular wavelengths in the near-infrared by using multilayer structures that enhance the absorption of light into the active device material. We describe the design of the multilayer structure enabling high detection efficiency TESs including issues and requirements for obtaining detection efficiency values higher than 99 %. We describe the device fabrication and finally, show recent results of devices optimized for high detection efficiency using the multilayer structure.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 20, 2010•51 citations

Boosting photon-number-resolved detection rates of transition-edge sensors by machine learning

Zhenghao Li, Matthew J. H. Kendall, Gerard J. Machado +7 more

Transition-edge sensors (TESs) are very effective photon-number-resolving (PNR) detectors that have enabled many photonic quantum technologies. However, their relatively slow thermal recovery time severely limits their operation rate in experimental scenarios compared with leading non-PNR detectors. In this work, we develop an algorithmic approach that enables TESs to detect and accurately classify photon pulses without waiting for a full recovery time between detection events. We propose two machine-learning-based signal processing methods: one supervised learning method and one unsupervised clustering method. By benchmarking against data obtained using coherent states and squeezed states, we show that the methods extend the TES operation rate to 800 kHz, achieving at least a four-fold improvement, whilst maintaining accurate photon-number assignment up to at least five photons. Our algorithms will find utility in applications where high rates of PNR detection are required and in technologies that demand fast active feed-forward of PNR detection outcomes.

arXiv:2411.15360•Optica Quantum•May 13, 2025•6 citations

Counting near-infrared single-photons with 95% efficiency

Adriana E. Lita, Aaron Miller, Sae Woo Nam

Single-photon detectors operating at visible and near-infrared wavelengths with high detection efficiency and low noise are a requirement for many quantum-information applications. Superconducting transition-edge sensors (TESs) are capable of detecting visible and near-infrared light at the single-photon level and are capable of discriminating between one- and two-photon absorption events; however these capabilities place stringent design requirements on the TES heat capacity, thermometry, and optical detection efficiency. We describe the fabrication and evaluation of a fiber-coupled, photon-number-resolving TES detector optimized for absorption at 1550 and 1310 nm wavelengths. The measured system detection efficiency at 1556 nm is 95 % +/- 2 %, which to our knowledge is the highest system detection efficiency reported for a near-infrared single-photon detector.

Optics Express•Jan 1, 2008•733 citations

Development of Titanium-Based Transition-Edge Single-Photon Detector

Wen Zhang, Yue Geng, Zheng Wang +7 more

Superconducting transition-edge sensors (TESs), working as single-photon detectors with high quantum efficiency, low dark count rate, and photon number resolving capability, have been successfully used in quantum information experiments as well as astronomical transient object observations. Aiming to achieve high count rate, we are developing titanium-based superconducting TES single-photon detectors with a critical temperature of ~300 mK. Ti-based TESs with active area from 10 × 10 μm to 40 × 40 μm are first fabricated on silicon substrate coated with SiOx. The fabricated TES devices show a thermal conductance scaling with the active area and an effective time constant of ~4 μs from pulsed laser diode illumination. In order to get high quantum efficiency, we further design and fabricate a 1550-nm optical cavity based on dielectric mirror and antireflection layer, and study its absorption with an IR spectrometer. Ti TES devices on the dielectric mirror are then fabricated and the superconducting transition is measured.

IEEE Transactions on Applied Superconductivity•Mar 19, 2019•19 citations
Transition-edge sensors (TESs) are very versatile superconducting devices used to detect radiation from gamma-rays to visible and submillimeter. The intrinsic capability to measure the energy of the absorbed photons with very high energy resolution and the related possibility to resolve the number of incident photons distinguish photon-number resolving (PNR) devices from any other photon detectors. PNR detectors are fundamental for the measurement of the photon-number distribution of singlephoton emitters and for the progress of quantum information technology and quantum metrology. By reducing the active area of TESs for visible-NIR light from typical values of 10-10m2toward 10-12m2and by increasing the TES operating temperature, we should be able to combine the high energy resolution permitted by very low heat capacity with fast response time. To support the future design and development of this new type of detector, in this work we compare experimental data with circuit simulation results based on the two-fluid theory.
Strong interests on optical quantum based metrology, quantum information and particularly in quantum cryptography are continuously growing. The main limitations to the developments in these fields are due to non-ideal devices: both single photon sources and single photon detectors. In these field of applications, detectors require to be able to resolve the number of photons in a light pulse. Presently state of the art indicates that classical semiconductor light detectors (i.e. avalanche photodiode or single photon avalanche diode) are not able to discriminate the number of photon arriving at the same time. In the meanwhile, superconducting devices have shown the possibility to resolve single photon pulses. One of the most promising superconducting detectors is the Transition-Edge Sensor (TES): a microcalorimeter that takes advantage of the sharp transition (few millikelvin) from the superconducting to the normal phase; for this reason it is sometimes called Superconductive Phase Thermometer (SPT). In the ultraviolet (UV) to infrared (IR) wavelength range, the photons are absorbed directly by the superconductive thin film and the absorbed energy induces an increase of the TES resistance. Thanks to the applied bias voltage, which maintains the device in the transition region the photon absorption induces a decrease of the TES current, measured by a dc-SQUID amplifier, and the pulse integral of the bias power reduction corresponds to the absorbed energy. This means that TESs have the very interesting properties to be able to detect single photons with an intrinsic energy resolution, without filters or gratings, that limit the quantum efficiency. By contrary of classical detectors, if monochromatic light irradiates TESs, as usually happens in communication systems, they show the photon-number resolving (PNR) capability and due to the good signal to noise ratio TESs are almost free from dark counts. Moreover, in the superconducting detector family, TESs are the only true photon-number resolving detectors operating in the VIS-NIR range. Together with quantum information science, the PNR property results useful even for optical radiometry too. In the optical community, the candela - the International System (SI) unit for the luminous intensity - has not a common consensus whether its present definition fully satisfies the current and future needs of growing associated technology. Furthermore, actually there are substantial efforts directed toward a new definitions of four base SI units: the proposal wants to link the SI units to fundamental constants, leaving f.i. material artifact. Considering the recent advances in optical radiometry and in quantum technologies, for the candela world it means redefine its unit linking to the Planck constant and consequently expressing the luminous intensity unit in terms of photon number rather than optical power. This challenge has been accepted by several national metrology institutes to demonstrate the feasibility of redefining the candela. Inside this research project called `qu-candela', the TES PNR capability has been considered to build the bridge between the quantum and classical world of radiometry: i.e. the detector possibility to measure optical powers from one single photon per second to the lower limits of cryogenic radiometry, 104 photons per second. The theme of this work of thesis is to investigate both optical and electrical characterization of different kind of TESs based on a titanium/gold multilayer film, produced and developed at the National Institute of Metrological Research (INRIM) of Torino. Thanks to the proximity effect, the multilayer allows to lower with continuity the critical temperature from that of the Ti bulk (Tc ~ 390 mK) to those of interest: ~ 300 mK and ~ 100 mK. Detectors with higher Tc have shown a faster response pulse with a relaxing time constant of the order of 200 ns, while for the lower Tc sensors, the time constant is about 10 µs. By contrary to the response time, the detector intrinsic energy resolution is proportional to its film critical temperature. Our sensors work to discriminate incident photon from UV wavelengths to those typical of the telecommunications, 1310 nm and 1550 nm. Irradiating a TES with an active area of 10x10 µm^2 by incident photons of 0.79 eV (corresponds to a wavelength 1570 nm), the best energy resolution obtained has been 0.18 eV. Detectors with higher active area 20x20 µm^2 have a worse energy resolution, because it is also proportional to the material film heat capacity. In the meanwhile due to the same reason these kind of sensors present a bigger saturation energy. This has allowed to investigate on the TES capability to discriminate up to 29 incident photons simultaneously. Until now, such count represents the bigger amount of photons discriminated by single photon detectors, without reaching the device saturation, with a linear behaviour. From this count it has been estimated 12 photons on average, per pulse, at 9 kHz repetition rate; this results in a photon flux of about 105 photons/s, demonstrating the possibility of having a detector able to work from low flux regime to 1 photon/s to flux measurable by conventional semiconductor device (f.i. single photon avalanche detector SPAD). An innovative absolute calibration technique for PNR detector has been demonstrated. The absolute technique is based on the Klyshko's efficient solution to measure detection efficiency in photon counting rate and well know for common click-no-click detector. In fact, exploiting the recent developments in quantum state world, it is possible to work with quasi single photon state, by using a parametric down conversion heralded single photon source, and calibrate PNR detectors without requiring reference standards. The best detection efficiency, of ca. 50%, has been reached by coupling the smaller active area detectors with a 9 µm core optical fiber, single mode at telecom wavelengths
Transition-Edge Sensors (TESs) are microcalorimeters that measure the energy of incident single photons by the resistance increase of a superconducting film biased within the superconducting-to-normal transition. TES are able to detect single photons from IR to X-ray with an intrinsic energy resolution and photon-number discrimination capability. Metrology, astronomy and quantum \ncommunication are the fields where these properties can be particularly useful. In this work, we report about characterization of different TESs based on Ti films. Single photons have been detected from 200nm to 800 nm working at transition temperature Tc ∼ 100 mK. Using a pulsed laser at 690nm we have demonstrated the capability to resolve up to five photons.
Superconducting photon detectors have emerged as a powerful new option for detecting single photons. System detection efficiency that incorporates the quantum efficiency of the device and system losses is one of the most important single-photon detector performance metrics for quantum information applications. Superconducting transition-edge sensors (TESs) are microcalorimeters that have the ability of distinguishing single photons with negligible dark counts. In addition, TESs are capable of directly measuring the photon number in a pulse of light. We have achieved near-unity system detection efficiency with TESs at particular wavelengths in the near-infrared by using multilayer structures that enhance the absorption of light into the active device material. We describe the design of the multilayer structure enabling high detection efficiency TESs including issues and requirements for obtaining detection efficiency values higher than 99 %. We describe the device fabrication and finally, show recent results of devices optimized for high detection efficiency using the multilayer structure.
Transition-edge sensors (TESs) are very effective photon-number-resolving (PNR) detectors that have enabled many photonic quantum technologies. However, their relatively slow thermal recovery time severely limits their operation rate in experimental scenarios compared with leading non-PNR detectors. In this work, we develop an algorithmic approach that enables TESs to detect and accurately classify photon pulses without waiting for a full recovery time between detection events. We propose two machine-learning-based signal processing methods: one supervised learning method and one unsupervised clustering method. By benchmarking against data obtained using coherent states and squeezed states, we show that the methods extend the TES operation rate to 800 kHz, achieving at least a four-fold improvement, whilst maintaining accurate photon-number assignment up to at least five photons. Our algorithms will find utility in applications where high rates of PNR detection are required and in technologies that demand fast active feed-forward of PNR detection outcomes.
Single-photon detectors operating at visible and near-infrared wavelengths with high detection efficiency and low noise are a requirement for many quantum-information applications. Superconducting transition-edge sensors (TESs) are capable of detecting visible and near-infrared light at the single-photon level and are capable of discriminating between one- and two-photon absorption events; however these capabilities place stringent design requirements on the TES heat capacity, thermometry, and optical detection efficiency. We describe the fabrication and evaluation of a fiber-coupled, photon-number-resolving TES detector optimized for absorption at 1550 and 1310 nm wavelengths. The measured system detection efficiency at 1556 nm is 95 % +/- 2 %, which to our knowledge is the highest system detection efficiency reported for a near-infrared single-photon detector.
Superconducting transition-edge sensors (TESs), working as single-photon detectors with high quantum efficiency, low dark count rate, and photon number resolving capability, have been successfully used in quantum information experiments as well as astronomical transient object observations. Aiming to achieve high count rate, we are developing titanium-based superconducting TES single-photon detectors with a critical temperature of ~300 mK. Ti-based TESs with active area from 10 × 10 μm to 40 × 40 μm are first fabricated on silicon substrate coated with SiOx. The fabricated TES devices show a thermal conductance scaling with the active area and an effective time constant of ~4 μs from pulsed laser diode illumination. In order to get high quantum efficiency, we further design and fabricate a 1550-nm optical cavity based on dielectric mirror and antireflection layer, and study its absorption with an IR spectrometer. Ti TES devices on the dielectric mirror are then fabricated and the superconducting transition is measured.