Preliminary results on the stabilization of a 1772-MHz oscillator to a resonance Raman transition in an atomic beam of sodium are presented. Short-term stability of 5.6 x 10(-11) (tau = 100 sec) for a 15-cm Ramsey interaction-region separation has been achieved. Sources of frequency drift are briefly discussed.
Precision studies of stimulated-resonance Raman interactions in a sodium atomic beam were performed with emphasis on Ramsey’s separated-field excitation. Ramsey fringes were obtained for a field separation of up to 30 cm, and the data were consistent with theoretical predictions. Possible applications of this Raman interaction to clock development also were studied by stabilizing a microwave oscillator to a Raman–Ramsey fringe. The resulting oscillator stability of 1.5 × 10−11 for a 1000-sec averaging time compares favorably with commercial cesium clocks when differences in atom transit time and transition frequency are taken into consideration. Finally, potential sources of long-term frequency error, which are important for clock applications, were also partially investigated.
SummaryIn this paper we reported our progress toward an atomic beam clock based on a transverse cooled rubidium beam. The atomic beam is generated from an atomic oven and collimated via micro-channel arrays and a two-dimensional optical lattice. After optical pumping, the rubidium beam interacts with two spatially separated Raman beams with a π/2 − π/2 sequence. High contrast Raman-Ramsey fringes are observed by using fluorescence detection. Preliminary result shows that the estimated frequency stability of the atomic clock reaches $2.6 \times {10^{ - 11}}/\sqrt \tau $. The atomic beam clock is proposed as a part of atomic beam inertial navigation unit for field applications.
We describe a method to stabilize the amplitude of the interrogating microwave field in compact atomic clocks working in a Ramsey approach. In this technique, we take advantage of the pulsed regime to use the atoms themselves as microwave amplitude discriminators. Specifically, in addition to the dependence on the microwave detuning, the atomic signal after the Ramsey interrogation acquires a dependence on the microwave pulse area (amplitude times duration) that can be exploited to implement an active stabilization of the microwave field amplitude, in a similar way in which the Ramsey clock signal is used to lock the local oscillator frequency to the atomic reference. This stabilization results in a reduced sensitivity of the clock frequency to microwave amplitude fluctuations that are transferred to the atoms through the cavity-pulling effect. The proposed technique is then effective to improve the clock stability and drift on medium and long term. We demonstrate the method for a vapor-cell clock working with a hot sample of atoms but it can be extended to cold-atom compact clocks.